blob: 14d287bed33c4e65100d04458af127cdc6bfa0d5 [file] [log] [blame]
#
# Intel network device configuration
#
config NET_VENDOR_INTEL
bool "Intel devices"
default y
---help---
If you have a network (Ethernet) card belonging to this class, say Y.
Note that the answer to this question doesn't directly affect the
kernel: saying N will just cause the configurator to skip all
the questions about Intel cards. If you say Y, you will be asked for
your specific card in the following questions.
if NET_VENDOR_INTEL
config E100
tristate "Intel(R) PRO/100+ support"
depends on PCI
select MII
---help---
This driver supports Intel(R) PRO/100 family of adapters.
To verify that your adapter is supported, find the board ID number
on the adapter. Look for a label that has a barcode and a number
in the format 123456-001 (six digits hyphen three digits).
Use the above information and the Adapter & Driver ID Guide that
can be located at:
<http://support.intel.com>
to identify the adapter.
More specific information on configuring the driver is in
<file:Documentation/networking/e100.txt>.
To compile this driver as a module, choose M here. The module
will be called e100.
config E1000
tristate "Intel(R) PRO/1000 Gigabit Ethernet support"
depends on PCI
---help---
This driver supports Intel(R) PRO/1000 gigabit ethernet family of
adapters. For more information on how to identify your adapter, go
to the Adapter & Driver ID Guide that can be located at:
<http://support.intel.com>
More specific information on configuring the driver is in
<file:Documentation/networking/e1000.txt>.
To compile this driver as a module, choose M here. The module
will be called e1000.
config E1000E
tristate "Intel(R) PRO/1000 PCI-Express Gigabit Ethernet support"
depends on PCI && (!SPARC32 || BROKEN)
select CRC32
imply PTP_1588_CLOCK
---help---
This driver supports the PCI-Express Intel(R) PRO/1000 gigabit
ethernet family of adapters. For PCI or PCI-X e1000 adapters,
use the regular e1000 driver For more information on how to
identify your adapter, go to the Adapter & Driver ID Guide that
can be located at:
<http://support.intel.com>
To compile this driver as a module, choose M here. The module
will be called e1000e.
config E1000E_HWTS
bool "Support HW cross-timestamp on PCH devices"
default y
depends on E1000E && X86
---help---
Say Y to enable hardware supported cross-timestamping on PCH
devices. The cross-timestamp is available through the PTP clock
driver precise cross-timestamp ioctl (PTP_SYS_OFFSET_PRECISE).
config IGB
tristate "Intel(R) 82575/82576 PCI-Express Gigabit Ethernet support"
depends on PCI
imply PTP_1588_CLOCK
select I2C
select I2C_ALGOBIT
---help---
This driver supports Intel(R) 82575/82576 gigabit ethernet family of
adapters. For more information on how to identify your adapter, go
to the Adapter & Driver ID Guide that can be located at:
<http://support.intel.com>
More specific information on configuring the driver is in
<file:Documentation/networking/e1000.txt>.
To compile this driver as a module, choose M here. The module
will be called igb.
config IGB_HWMON
bool "Intel(R) PCI-Express Gigabit adapters HWMON support"
default y
depends on IGB && HWMON && !(IGB=y && HWMON=m)
---help---
Say Y if you want to expose thermal sensor data on Intel devices.
Some of our devices contain thermal sensors, both external and internal.
This data is available via the hwmon sysfs interface and exposes
the onboard sensors.
config IGB_DCA
bool "Direct Cache Access (DCA) Support"
default y
depends on IGB && DCA && !(IGB=y && DCA=m)
---help---
Say Y here if you want to use Direct Cache Access (DCA) in the
driver. DCA is a method for warming the CPU cache before data
is used, with the intent of lessening the impact of cache misses.
config IGBVF
tristate "Intel(R) 82576 Virtual Function Ethernet support"
depends on PCI
---help---
This driver supports Intel(R) 82576 virtual functions. For more
information on how to identify your adapter, go to the Adapter &
Driver ID Guide that can be located at:
<http://support.intel.com>
More specific information on configuring the driver is in
<file:Documentation/networking/e1000.txt>.
To compile this driver as a module, choose M here. The module
will be called igbvf.
config IXGB
tristate "Intel(R) PRO/10GbE support"
depends on PCI
---help---
This driver supports Intel(R) PRO/10GbE family of adapters for
PCI-X type cards. For PCI-E type cards, use the "ixgbe" driver
instead. For more information on how to identify your adapter, go
to the Adapter & Driver ID Guide that can be located at:
<http://support.intel.com>
More specific information on configuring the driver is in
<file:Documentation/networking/ixgb.txt>.
To compile this driver as a module, choose M here. The module
will be called ixgb.
config IXGBE
tristate "Intel(R) 10GbE PCI Express adapters support"
depends on PCI
select MDIO
imply PTP_1588_CLOCK
---help---
This driver supports Intel(R) 10GbE PCI Express family of
adapters. For more information on how to identify your adapter, go
to the Adapter & Driver ID Guide that can be located at:
<http://support.intel.com>
To compile this driver as a module, choose M here. The module
will be called ixgbe.
config IXGBE_HWMON
bool "Intel(R) 10GbE PCI Express adapters HWMON support"
default y
depends on IXGBE && HWMON && !(IXGBE=y && HWMON=m)
---help---
Say Y if you want to expose the thermal sensor data on some of
our cards, via a hwmon sysfs interface.
config IXGBE_DCA
bool "Direct Cache Access (DCA) Support"
default y
depends on IXGBE && DCA && !(IXGBE=y && DCA=m)
---help---
Say Y here if you want to use Direct Cache Access (DCA) in the
driver. DCA is a method for warming the CPU cache before data
is used, with the intent of lessening the impact of cache misses.
config IXGBE_DCB
bool "Data Center Bridging (DCB) Support"
default n
depends on IXGBE && DCB
---help---
Say Y here if you want to use Data Center Bridging (DCB) in the
driver.
If unsure, say N.
config IXGBEVF
tristate "Intel(R) 10GbE PCI Express Virtual Function Ethernet support"
depends on PCI_MSI
---help---
This driver supports Intel(R) PCI Express virtual functions for the
Intel(R) ixgbe driver. For more information on how to identify your
adapter, go to the Adapter & Driver ID Guide that can be located at:
<http://support.intel.com>
More specific information on configuring the driver is in
<file:Documentation/networking/ixgbevf.txt>.
To compile this driver as a module, choose M here. The module
will be called ixgbevf. MSI-X interrupt support is required
for this driver to work correctly.
config I40E
tristate "Intel(R) Ethernet Controller XL710 Family support"
imply PTP_1588_CLOCK
depends on PCI
---help---
This driver supports Intel(R) Ethernet Controller XL710 Family of
devices. For more information on how to identify your adapter, go
to the Adapter & Driver ID Guide that can be located at:
<http://support.intel.com>
To compile this driver as a module, choose M here. The module
will be called i40e.
config I40E_DCB
bool "Data Center Bridging (DCB) Support"
default n
depends on I40E && DCB
---help---
Say Y here if you want to use Data Center Bridging (DCB) in the
driver.
If unsure, say N.
config I40EVF
tristate "Intel(R) Ethernet Adaptive Virtual Function support"
depends on PCI_MSI
---help---
This driver supports virtual functions for Intel XL710,
X710, X722, and all devices advertising support for Intel
Ethernet Adaptive Virtual Function devices. For more
information on how to identify your adapter, go to the Adapter
& Driver ID Guide that can be located at:
<http://support.intel.com>
To compile this driver as a module, choose M here. The module
will be called i40evf. MSI-X interrupt support is required
for this driver to work correctly.
config ICE
tristate "Intel(R) Ethernet Connection E800 Series Support"
default n
depends on PCI_MSI
---help---
This driver supports Intel(R) Ethernet Connection E800 Series of
devices. For more information on how to identify your adapter, go
to the Adapter & Driver ID Guide that can be located at:
<http://support.intel.com>
To compile this driver as a module, choose M here. The module
will be called ice.
config FM10K
tristate "Intel(R) FM10000 Ethernet Switch Host Interface Support"
default n
depends on PCI_MSI
imply PTP_1588_CLOCK
---help---
This driver supports Intel(R) FM10000 Ethernet Switch Host
Interface. For more information on how to identify your adapter,
go to the Adapter & Driver ID Guide that can be located at:
<http://support.intel.com>
To compile this driver as a module, choose M here. The module
will be called fm10k. MSI-X interrupt support is required
endif # NET_VENDOR_INTEL