dmaengine: sun6i: Correct setting of clock autogating register for A83T/H3
The H83T uses a compatible string different from the A23, but requires
the same clock autogating register setting.
The H3 also requires setting the clock autogating register, but has
the register at a different offset.
Add three suitable callbacks for the existing controller generations
and set it in the controller config structure.
Signed-off-by: Stefan Brüns <stefan.bruens@rwth-aachen.de>
Acked-by: Maxime Ripard <maxime.ripard@free-electrons.com>
Signed-off-by: Vinod Koul <vinod.koul@intel.com>
1 file changed