USB: twl4030: Enable USB regulators before enabling USB charging

For TWL family of power management ICs, USB charging works only
when USB regulators are in enabled state: 3v1, 1v5, 1v8

On a USB cable attach, twl4030_phy_resume(twl) function enables
the regulators. Enable USB charging, only after all regulators
are enabled.

Its observed that enabling USB charging before regulators are
enabled, causes USB charging to fail.

Tested on: Zoom2: omap3430: ES3.1 + TWL5030
Needs T2-MADC and T2-BCI drivers which are still not upstreamed.

Signed-off-by: Moiz Sonasath <m-sonasath@ti.com>
Signed-off-by: Leed Aguilar <leed.aguilar@ti.com>
Acked-by: Vikram Pandita <vikram.pandita@ti.com>
Acked-by: Anand Gadiyar <gadiyar@ti.com>
Acked-by: Nishanth Menon <nm@ti.com>
Acked-by: Felipe Balbi <felipe.balbi@nokia.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>