hwmon: Driver for TI TMP102 temperature sensor

Driver for the TI TMP102.

The TI TMP102 is similar to the LM75.  It differs from the LM75 by
having a 16-bit conf register and the temp registers have a minimum
resolution of 12 bits; the extended conf register can select 13-bit
resolution (which this driver does) and also change the update rate
(which this driver currently doesn't use).

[JD: Fix tmp102_exit tag, must be __exit, not __init.]

Signed-off-by: Steven King <sfking@fdwdc.com>
Signed-off-by: Jean Delvare <khali@linux-fr.org>
diff --git a/Documentation/hwmon/tmp102 b/Documentation/hwmon/tmp102
new file mode 100644
index 0000000..239dded
--- /dev/null
+++ b/Documentation/hwmon/tmp102
@@ -0,0 +1,27 @@
+Kernel driver tmp102
+====================
+
+Supported chips:
+  * Texas Instruments TMP102
+    Prefix: 'tmp102'
+    Addresses scanned: I2C 0x48 0x49 0x4a 0x4b
+    Datasheet: http://focus.ti.com/docs/prod/folders/print/tmp102.html
+
+Author:
+	Steven King <sfking@fdwdc.com>
+
+Description
+-----------
+
+The Texas Instruments TMP102 implements one temperature sensor.  Limits can be
+set through the Overtemperature Shutdown register and Hysteresis register.  The
+sensor is accurate to 0.5 degrees over the range of -25 to +85 C, and to 1.0
+degrees from -40 to +125 C. Resolution of the sensor is 0.0625 degree.  The
+operating temperature has a minimum of -55 C and a maximum of +150 C.
+
+The TMP102 has a programmable update rate that can select between 8, 4, 1, and
+0.5 Hz. (Currently the driver only supports the default of 4 Hz).
+
+The driver provides the common sysfs-interface for temperatures (see
+/Documentation/hwmon/sysfs-interface under Temperatures).
+