blkio-throttle: Fix possible multiplication overflow in iops calculations

o User can specify max iops value of 32bit (UINT_MAX), through cgroup
  interface. If a user has specified say 4294967294 (UNIT_MAX  - 2), then
  on 32bit platform, following multiplication can overflow.

  io_allowed = (tg->iops[rw] * jiffy_elapsed_rnd)

o Explicitly cast the multiplication to 64bit and then perform division and
  then check whether result is still great then UNINT_MAX.

Signed-off-by: Vivek Goyal <vgoyal@redhat.com>
Signed-off-by: Jens Axboe <jaxboe@fusionio.com>
1 file changed