bnx2x: Fix KR2 rapid link flap

Check KR2 recovery time at the beginning of the work-around function.

Signed-off-by: Yaniv Rosner <yanivr@broadcom.com>
Signed-off-by: Eilon Greenstein <eilong@broadcom.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
diff --git a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_link.c b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_link.c
index 77ebae0..0283f34 100644
--- a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_link.c
+++ b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_link.c
@@ -13437,13 +13437,7 @@
 {
 	struct bnx2x *bp = params->bp;
 	u16 base_page, next_page, not_kr2_device, lane;
-	int sigdet = bnx2x_warpcore_get_sigdet(phy, params);
-
-	if (!sigdet) {
-		if (!(vars->link_attr_sync & LINK_ATTR_SYNC_KR2_ENABLE))
-			bnx2x_kr2_recovery(params, vars, phy);
-		return;
-	}
+	int sigdet;
 
 	/* Once KR2 was disabled, wait 5 seconds before checking KR2 recovery
 	 * since some switches tend to reinit the AN process and clear the
@@ -13454,6 +13448,16 @@
 		vars->check_kr2_recovery_cnt--;
 		return;
 	}
+
+	sigdet = bnx2x_warpcore_get_sigdet(phy, params);
+	if (!sigdet) {
+		if (!(vars->link_attr_sync & LINK_ATTR_SYNC_KR2_ENABLE)) {
+			bnx2x_kr2_recovery(params, vars, phy);
+			DP(NETIF_MSG_LINK, "No sigdet\n");
+		}
+		return;
+	}
+
 	lane = bnx2x_get_warpcore_lane(phy, params);
 	CL22_WR_OVER_CL45(bp, phy, MDIO_REG_BANK_AER_BLOCK,
 			  MDIO_AER_BLOCK_AER_REG, lane);