OMAP1: PM: register notifiers with generic clock ops even when !PM_RUNTIME

When runtime PM is disabled, device clocks need to be enabled on
device add and disabled on device remove.  This currently is not
happening because in the !PM_RUNTIME case, no notifiers are registered
for OMAP1 devices.

Fix this by ensuring notifiers are registered, even in the !PM_RUNTIME case.

Reported-by: Janusz Krzysztofik <jkrzyszt@tis.icnet.pl>
Tested-by: Janusz Krzysztofik <jkrzyszt@tis.icnet.pl>
Signed-off-by: Kevin Hilman <khilman@ti.com>
Signed-off-by: Tony Lindgren <tony@atomide.com>
diff --git a/arch/arm/mach-omap1/pm_bus.c b/arch/arm/mach-omap1/pm_bus.c
index fe31d93..334fb88 100644
--- a/arch/arm/mach-omap1/pm_bus.c
+++ b/arch/arm/mach-omap1/pm_bus.c
@@ -56,9 +56,13 @@
 		USE_PLATFORM_PM_SLEEP_OPS
 	},
 };
+#define OMAP1_PWR_DOMAIN (&default_power_domain)
+#else
+#define OMAP1_PWR_DOMAIN NULL
+#endif /* CONFIG_PM_RUNTIME */
 
 static struct pm_clk_notifier_block platform_bus_notifier = {
-	.pwr_domain = &default_power_domain,
+	.pwr_domain = OMAP1_PWR_DOMAIN,
 	.con_ids = { "ick", "fck", NULL, },
 };
 
@@ -72,4 +76,4 @@
 	return 0;
 }
 core_initcall(omap1_pm_runtime_init);
-#endif /* CONFIG_PM_RUNTIME */
+