net: cdc_ncm: fix probing of devices with multiple control interface altsettings
commit bd329e1 ("net: cdc_ncm: do not bind to NCM compatible MBIM devices")
added a test for a CDC MBIM altsetting, implementing the cdc_ncm part of
MBIM backward compatibility support. This intentionally made the driver
behave differently for CDC NCM devices with 2 alternate settings for the
Communication interface, depending on whether or not CONFIG_USB_NET_CDC_MBIM
was enabled. This is correct iff alternate setting #1 really *is* a MBIM
setting. If not, then NCM probing will use a different altsetting than before,
possibly causing probing failures depending on CONFIG_USB_NET_CDC_MBIM.
Fix by setting the altsetting back to default after the test, restoring the
previous behaviour for non MBIM devices.
This bug causes probing of Huawei E3276 devices to fail when the MBIM driver
is enabled, because these devices have a second alternate setting with no CDC
functional descriptors.
Cc: Greg Suarez <gsuarez@smithmicro.com>
Cc: Alexey Orishko <alexey.orishko@stericsson.com>
Reported-and-tested-by: Jonathan A. <yo.natan@hotmail.com>
Signed-off-by: Bjørn Mork <bjorn@mork.no>
Signed-off-by: David S. Miller <davem@davemloft.net>
1 file changed