blob: 558fe528ae1951104b6266a2f5ed4849017c6b35 [file] [log] [blame]
* Renesas RCar PCIe interface
Required properties:
compatible: "renesas,pcie-r8a7779" for the R8A7779 SoC;
"renesas,pcie-r8a7790" for the R8A7790 SoC;
"renesas,pcie-r8a7791" for the R8A7791 SoC;
"renesas,pcie-r8a7795" for the R8A7795 SoC;
"renesas,pcie-rcar-gen2" for a generic R-Car Gen2 compatible device.
When compatible with the generic version, nodes must list the
SoC-specific version corresponding to the platform first
followed by the generic version.
- reg: base address and length of the pcie controller registers.
- #address-cells: set to <3>
- #size-cells: set to <2>
- bus-range: PCI bus numbers covered
- device_type: set to "pci"
- ranges: ranges for the PCI memory and I/O regions.
- dma-ranges: ranges for the inbound memory regions.
- interrupts: two interrupt sources for MSI interrupts, followed by interrupt
source for hardware related interrupts (e.g. link speed change).
- #interrupt-cells: set to <1>
- interrupt-map-mask and interrupt-map: standard PCI properties
to define the mapping of the PCIe interface to interrupt
numbers.
- clocks: from common clock binding: clock specifiers for the PCIe controller
and PCIe bus clocks.
- clock-names: from common clock binding: should be "pcie" and "pcie_bus".
Example:
SoC specific DT Entry:
pcie: pcie@fe000000 {
compatible = "renesas,pcie-r8a7791", "renesas,pcie-rcar-gen2";
reg = <0 0xfe000000 0 0x80000>;
#address-cells = <3>;
#size-cells = <2>;
bus-range = <0x00 0xff>;
device_type = "pci";
ranges = <0x01000000 0 0x00000000 0 0xfe100000 0 0x00100000
0x02000000 0 0xfe200000 0 0xfe200000 0 0x00200000
0x02000000 0 0x30000000 0 0x30000000 0 0x08000000
0x42000000 0 0x38000000 0 0x38000000 0 0x08000000>;
dma-ranges = <0x42000000 0 0x40000000 0 0x40000000 0 0x40000000
0x42000000 2 0x00000000 2 0x00000000 0 0x40000000>;
interrupts = <0 116 4>, <0 117 4>, <0 118 4>;
#interrupt-cells = <1>;
interrupt-map-mask = <0 0 0 0>;
interrupt-map = <0 0 0 0 &gic 0 116 4>;
clocks = <&mstp3_clks R8A7791_CLK_PCIE>, <&pcie_bus_clk>;
clock-names = "pcie", "pcie_bus";
status = "disabled";
};