| # SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause) |
| %YAML 1.2 |
| --- |
| $id: http://devicetree.org/schemas/iio/pressure/honeywell,hsc030pa.yaml# |
| $schema: http://devicetree.org/meta-schemas/core.yaml# |
| |
| title: Honeywell TruStability HSC and SSC pressure sensor series |
| |
| description: | |
| support for Honeywell TruStability HSC and SSC digital pressure sensor |
| series. |
| |
| These sensors have either an I2C, an SPI or an analog interface. Only the |
| digital versions are supported by this driver. |
| |
| There are 118 models with different pressure ranges available in each family. |
| The vendor calls them "HSC series" and "SSC series". All of them have an |
| identical programming model but differ in pressure range, unit and transfer |
| function. |
| |
| To support different models one needs to specify the pressure range as well |
| as the transfer function. Pressure range can either be provided via |
| pressure-triplet (directly extracted from the part number) or in case it's |
| a custom chip via numerical range limits converted to pascals. |
| |
| The transfer function defines the ranges of raw conversion values delivered |
| by the sensor. pmin-pascal and pmax-pascal corespond to the minimum and |
| maximum pressure that can be measured. |
| |
| Please note that in case of an SPI-based sensor, the clock signal should not |
| exceed 800kHz and the MOSI signal is not required. |
| |
| Specifications about the devices can be found at: |
| https://prod-edam.honeywell.com/content/dam/honeywell-edam/sps/siot/en-us/products/sensors/pressure-sensors/board-mount-pressure-sensors/trustability-hsc-series/documents/sps-siot-trustability-hsc-series-high-accuracy-board-mount-pressure-sensors-50099148-a-en-ciid-151133.pdf |
| https://prod-edam.honeywell.com/content/dam/honeywell-edam/sps/siot/en-us/products/sensors/pressure-sensors/board-mount-pressure-sensors/trustability-ssc-series/documents/sps-siot-trustability-ssc-series-standard-accuracy-board-mount-pressure-sensors-50099533-a-en-ciid-151134.pdf |
| |
| maintainers: |
| - Petre Rodan <petre.rodan@subdimension.ro> |
| |
| properties: |
| compatible: |
| const: honeywell,hsc030pa |
| |
| reg: |
| maxItems: 1 |
| |
| honeywell,transfer-function: |
| description: | |
| Transfer function which defines the range of valid values delivered by |
| the sensor. |
| 0 - A, 10% to 90% of 2^14 |
| 1 - B, 5% to 95% of 2^14 |
| 2 - C, 5% to 85% of 2^14 |
| 3 - F, 4% to 94% of 2^14 |
| enum: [0, 1, 2, 3] |
| $ref: /schemas/types.yaml#/definitions/uint32 |
| |
| honeywell,pressure-triplet: |
| description: | |
| Case-sensitive five character string that defines pressure range, unit |
| and type as part of the device nomenclature. In the unlikely case of a |
| custom chip, set to "NA" and provide pmin-pascal and pmax-pascal. |
| enum: [001BA, 1.6BA, 2.5BA, 004BA, 006BA, 010BA, 1.6MD, 2.5MD, 004MD, |
| 006MD, 010MD, 016MD, 025MD, 040MD, 060MD, 100MD, 160MD, 250MD, |
| 400MD, 600MD, 001BD, 1.6BD, 2.5BD, 004BD, 2.5MG, 004MG, 006MG, |
| 010MG, 016MG, 025MG, 040MG, 060MG, 100MG, 160MG, 250MG, 400MG, |
| 600MG, 001BG, 1.6BG, 2.5BG, 004BG, 006BG, 010BG, 100KA, 160KA, |
| 250KA, 400KA, 600KA, 001GA, 160LD, 250LD, 400LD, 600LD, 001KD, |
| 1.6KD, 2.5KD, 004KD, 006KD, 010KD, 016KD, 025KD, 040KD, 060KD, |
| 100KD, 160KD, 250KD, 400KD, 250LG, 400LG, 600LG, 001KG, 1.6KG, |
| 2.5KG, 004KG, 006KG, 010KG, 016KG, 025KG, 040KG, 060KG, 100KG, |
| 160KG, 250KG, 400KG, 600KG, 001GG, 015PA, 030PA, 060PA, 100PA, |
| 150PA, 0.5ND, 001ND, 002ND, 004ND, 005ND, 010ND, 020ND, 030ND, |
| 001PD, 005PD, 015PD, 030PD, 060PD, 001NG, 002NG, 004NG, 005NG, |
| 010NG, 020NG, 030NG, 001PG, 005PG, 015PG, 030PG, 060PG, 100PG, |
| 150PG, NA] |
| $ref: /schemas/types.yaml#/definitions/string |
| |
| honeywell,pmin-pascal: |
| description: | |
| Minimum pressure value the sensor can measure in pascal. |
| To be specified only if honeywell,pressure-triplet is set to "NA". |
| |
| honeywell,pmax-pascal: |
| description: | |
| Maximum pressure value the sensor can measure in pascal. |
| To be specified only if honeywell,pressure-triplet is set to "NA". |
| |
| vdd-supply: |
| description: |
| Provide VDD power to the sensor (either 3.3V or 5V depending on the chip) |
| |
| spi-max-frequency: |
| maximum: 800000 |
| |
| required: |
| - compatible |
| - reg |
| - honeywell,transfer-function |
| - honeywell,pressure-triplet |
| |
| allOf: |
| - $ref: /schemas/spi/spi-peripheral-props.yaml |
| |
| additionalProperties: false |
| |
| dependentSchemas: |
| honeywell,pmin-pascal: |
| properties: |
| honeywell,pressure-triplet: |
| const: NA |
| honeywell,pmax-pascal: |
| properties: |
| honeywell,pressure-triplet: |
| const: NA |
| |
| examples: |
| - | |
| i2c { |
| #address-cells = <1>; |
| #size-cells = <0>; |
| |
| pressure@28 { |
| compatible = "honeywell,hsc030pa"; |
| reg = <0x28>; |
| honeywell,transfer-function = <0>; |
| honeywell,pressure-triplet = "030PA"; |
| }; |
| }; |
| - | |
| spi { |
| #address-cells = <1>; |
| #size-cells = <0>; |
| |
| pressure@0 { |
| compatible = "honeywell,hsc030pa"; |
| reg = <0>; |
| spi-max-frequency = <800000>; |
| honeywell,transfer-function = <0>; |
| honeywell,pressure-triplet = "NA"; |
| honeywell,pmin-pascal = <0>; |
| honeywell,pmax-pascal = <200000>; |
| }; |
| }; |
| ... |