| // SPDX-License-Identifier: GPL-2.0 |
| /* |
| * Power supply driver for ChromeOS EC based Peripheral Device Charger. |
| * |
| * Copyright 2020 Google LLC. |
| */ |
| |
| #include <linux/module.h> |
| #include <linux/notifier.h> |
| #include <linux/platform_data/cros_ec_commands.h> |
| #include <linux/platform_data/cros_ec_proto.h> |
| #include <linux/platform_device.h> |
| #include <linux/power_supply.h> |
| #include <linux/slab.h> |
| #include <linux/stringify.h> |
| #include <linux/types.h> |
| #include <asm/unaligned.h> |
| |
| #define DRV_NAME "cros-ec-pchg" |
| #define PCHG_DIR_PREFIX "peripheral" |
| #define PCHG_DIR_NAME PCHG_DIR_PREFIX "%d" |
| #define PCHG_DIR_NAME_LENGTH \ |
| sizeof(PCHG_DIR_PREFIX __stringify(EC_PCHG_MAX_PORTS)) |
| #define PCHG_CACHE_UPDATE_DELAY msecs_to_jiffies(500) |
| |
| struct port_data { |
| int port_number; |
| char name[PCHG_DIR_NAME_LENGTH]; |
| struct power_supply *psy; |
| struct power_supply_desc psy_desc; |
| int psy_status; |
| int battery_percentage; |
| int charge_type; |
| struct charger_data *charger; |
| unsigned long last_update; |
| }; |
| |
| struct charger_data { |
| struct device *dev; |
| struct cros_ec_dev *ec_dev; |
| struct cros_ec_device *ec_device; |
| int num_registered_psy; |
| struct port_data *ports[EC_PCHG_MAX_PORTS]; |
| struct notifier_block notifier; |
| }; |
| |
| static enum power_supply_property cros_pchg_props[] = { |
| POWER_SUPPLY_PROP_STATUS, |
| POWER_SUPPLY_PROP_CHARGE_TYPE, |
| POWER_SUPPLY_PROP_CAPACITY, |
| POWER_SUPPLY_PROP_SCOPE, |
| }; |
| |
| static int cros_pchg_ec_command(const struct charger_data *charger, |
| unsigned int version, |
| unsigned int command, |
| const void *outdata, |
| unsigned int outsize, |
| void *indata, |
| unsigned int insize) |
| { |
| struct cros_ec_dev *ec_dev = charger->ec_dev; |
| struct cros_ec_command *msg; |
| int ret; |
| |
| msg = kzalloc(struct_size(msg, data, max(outsize, insize)), GFP_KERNEL); |
| if (!msg) |
| return -ENOMEM; |
| |
| msg->version = version; |
| msg->command = ec_dev->cmd_offset + command; |
| msg->outsize = outsize; |
| msg->insize = insize; |
| |
| if (outsize) |
| memcpy(msg->data, outdata, outsize); |
| |
| ret = cros_ec_cmd_xfer_status(charger->ec_device, msg); |
| if (ret >= 0 && insize) |
| memcpy(indata, msg->data, insize); |
| |
| kfree(msg); |
| return ret; |
| } |
| |
| static const unsigned int pchg_cmd_version = 1; |
| |
| static bool cros_pchg_cmd_ver_check(const struct charger_data *charger) |
| { |
| struct ec_params_get_cmd_versions_v1 req; |
| struct ec_response_get_cmd_versions rsp; |
| int ret; |
| |
| req.cmd = EC_CMD_PCHG; |
| ret = cros_pchg_ec_command(charger, 1, EC_CMD_GET_CMD_VERSIONS, |
| &req, sizeof(req), &rsp, sizeof(rsp)); |
| if (ret < 0) { |
| dev_warn(charger->dev, |
| "Unable to get versions of EC_CMD_PCHG (err:%d)\n", |
| ret); |
| return false; |
| } |
| |
| return !!(rsp.version_mask & BIT(pchg_cmd_version)); |
| } |
| |
| static int cros_pchg_port_count(const struct charger_data *charger) |
| { |
| struct ec_response_pchg_count rsp; |
| int ret; |
| |
| ret = cros_pchg_ec_command(charger, 0, EC_CMD_PCHG_COUNT, |
| NULL, 0, &rsp, sizeof(rsp)); |
| if (ret < 0) { |
| dev_warn(charger->dev, |
| "Unable to get number or ports (err:%d)\n", ret); |
| return ret; |
| } |
| |
| return rsp.port_count; |
| } |
| |
| static int cros_pchg_get_status(struct port_data *port) |
| { |
| struct charger_data *charger = port->charger; |
| struct ec_params_pchg req; |
| struct ec_response_pchg rsp; |
| struct device *dev = charger->dev; |
| int old_status = port->psy_status; |
| int old_percentage = port->battery_percentage; |
| int ret; |
| |
| req.port = port->port_number; |
| ret = cros_pchg_ec_command(charger, pchg_cmd_version, EC_CMD_PCHG, |
| &req, sizeof(req), &rsp, sizeof(rsp)); |
| if (ret < 0) { |
| dev_err(dev, "Unable to get port.%d status (err:%d)\n", |
| port->port_number, ret); |
| return ret; |
| } |
| |
| switch (rsp.state) { |
| case PCHG_STATE_RESET: |
| case PCHG_STATE_INITIALIZED: |
| case PCHG_STATE_ENABLED: |
| default: |
| port->psy_status = POWER_SUPPLY_STATUS_UNKNOWN; |
| port->charge_type = POWER_SUPPLY_CHARGE_TYPE_NONE; |
| break; |
| case PCHG_STATE_DETECTED: |
| port->psy_status = POWER_SUPPLY_STATUS_CHARGING; |
| port->charge_type = POWER_SUPPLY_CHARGE_TYPE_TRICKLE; |
| break; |
| case PCHG_STATE_CHARGING: |
| port->psy_status = POWER_SUPPLY_STATUS_CHARGING; |
| port->charge_type = POWER_SUPPLY_CHARGE_TYPE_STANDARD; |
| break; |
| case PCHG_STATE_FULL: |
| port->psy_status = POWER_SUPPLY_STATUS_FULL; |
| port->charge_type = POWER_SUPPLY_CHARGE_TYPE_NONE; |
| break; |
| } |
| |
| port->battery_percentage = rsp.battery_percentage; |
| |
| if (port->psy_status != old_status || |
| port->battery_percentage != old_percentage) |
| power_supply_changed(port->psy); |
| |
| dev_dbg(dev, |
| "Port %d: state=%d battery=%d%%\n", |
| port->port_number, rsp.state, rsp.battery_percentage); |
| |
| return 0; |
| } |
| |
| static int cros_pchg_get_port_status(struct port_data *port, bool ratelimit) |
| { |
| int ret; |
| |
| if (ratelimit && |
| time_is_after_jiffies(port->last_update + PCHG_CACHE_UPDATE_DELAY)) |
| return 0; |
| |
| ret = cros_pchg_get_status(port); |
| if (ret < 0) |
| return ret; |
| |
| port->last_update = jiffies; |
| |
| return ret; |
| } |
| |
| static int cros_pchg_get_prop(struct power_supply *psy, |
| enum power_supply_property psp, |
| union power_supply_propval *val) |
| { |
| struct port_data *port = power_supply_get_drvdata(psy); |
| |
| switch (psp) { |
| case POWER_SUPPLY_PROP_STATUS: |
| case POWER_SUPPLY_PROP_CAPACITY: |
| case POWER_SUPPLY_PROP_CHARGE_TYPE: |
| cros_pchg_get_port_status(port, true); |
| break; |
| default: |
| break; |
| } |
| |
| switch (psp) { |
| case POWER_SUPPLY_PROP_STATUS: |
| val->intval = port->psy_status; |
| break; |
| case POWER_SUPPLY_PROP_CAPACITY: |
| val->intval = port->battery_percentage; |
| break; |
| case POWER_SUPPLY_PROP_CHARGE_TYPE: |
| val->intval = port->charge_type; |
| break; |
| case POWER_SUPPLY_PROP_SCOPE: |
| val->intval = POWER_SUPPLY_SCOPE_DEVICE; |
| break; |
| default: |
| return -EINVAL; |
| } |
| |
| return 0; |
| } |
| |
| static int cros_pchg_event(const struct charger_data *charger, |
| unsigned long host_event) |
| { |
| int i; |
| |
| for (i = 0; i < charger->num_registered_psy; i++) |
| cros_pchg_get_port_status(charger->ports[i], false); |
| |
| return NOTIFY_OK; |
| } |
| |
| static int cros_ec_notify(struct notifier_block *nb, |
| unsigned long queued_during_suspend, |
| void *data) |
| { |
| struct cros_ec_device *ec_dev = data; |
| struct charger_data *charger = |
| container_of(nb, struct charger_data, notifier); |
| u32 host_event; |
| |
| if (ec_dev->event_data.event_type != EC_MKBP_EVENT_PCHG || |
| ec_dev->event_size != sizeof(host_event)) |
| return NOTIFY_DONE; |
| |
| host_event = get_unaligned_le32(&ec_dev->event_data.data.host_event); |
| |
| if (!(host_event & EC_MKBP_PCHG_DEVICE_EVENT)) |
| return NOTIFY_DONE; |
| |
| return cros_pchg_event(charger, host_event); |
| } |
| |
| static int cros_pchg_probe(struct platform_device *pdev) |
| { |
| struct device *dev = &pdev->dev; |
| struct cros_ec_dev *ec_dev = dev_get_drvdata(dev->parent); |
| struct cros_ec_device *ec_device = ec_dev->ec_dev; |
| struct power_supply_desc *psy_desc; |
| struct charger_data *charger; |
| struct power_supply *psy; |
| struct port_data *port; |
| struct notifier_block *nb; |
| int num_ports; |
| int ret; |
| int i; |
| |
| charger = devm_kzalloc(dev, sizeof(*charger), GFP_KERNEL); |
| if (!charger) |
| return -ENOMEM; |
| |
| charger->dev = dev; |
| charger->ec_dev = ec_dev; |
| charger->ec_device = ec_device; |
| |
| ret = cros_pchg_port_count(charger); |
| if (ret <= 0) { |
| /* |
| * This feature is enabled by the EC and the kernel driver is |
| * included by default for CrOS devices. Don't need to be loud |
| * since this error can be normal. |
| */ |
| dev_info(dev, "No peripheral charge ports (err:%d)\n", ret); |
| return -ENODEV; |
| } |
| |
| if (!cros_pchg_cmd_ver_check(charger)) { |
| dev_err(dev, "EC_CMD_PCHG version %d isn't available.\n", |
| pchg_cmd_version); |
| return -EOPNOTSUPP; |
| } |
| |
| num_ports = ret; |
| if (num_ports > EC_PCHG_MAX_PORTS) { |
| dev_err(dev, "Too many peripheral charge ports (%d)\n", |
| num_ports); |
| return -ENOBUFS; |
| } |
| |
| dev_info(dev, "%d peripheral charge ports found\n", num_ports); |
| |
| for (i = 0; i < num_ports; i++) { |
| struct power_supply_config psy_cfg = {}; |
| |
| port = devm_kzalloc(dev, sizeof(*port), GFP_KERNEL); |
| if (!port) |
| return -ENOMEM; |
| |
| port->charger = charger; |
| port->port_number = i; |
| snprintf(port->name, sizeof(port->name), PCHG_DIR_NAME, i); |
| |
| psy_desc = &port->psy_desc; |
| psy_desc->name = port->name; |
| psy_desc->type = POWER_SUPPLY_TYPE_BATTERY; |
| psy_desc->get_property = cros_pchg_get_prop; |
| psy_desc->external_power_changed = NULL; |
| psy_desc->properties = cros_pchg_props; |
| psy_desc->num_properties = ARRAY_SIZE(cros_pchg_props); |
| psy_cfg.drv_data = port; |
| |
| psy = devm_power_supply_register(dev, psy_desc, &psy_cfg); |
| if (IS_ERR(psy)) |
| return dev_err_probe(dev, PTR_ERR(psy), |
| "Failed to register power supply\n"); |
| port->psy = psy; |
| |
| charger->ports[charger->num_registered_psy++] = port; |
| } |
| |
| if (!charger->num_registered_psy) |
| return -ENODEV; |
| |
| nb = &charger->notifier; |
| nb->notifier_call = cros_ec_notify; |
| ret = blocking_notifier_chain_register(&ec_dev->ec_dev->event_notifier, |
| nb); |
| if (ret < 0) |
| dev_err(dev, "Failed to register notifier (err:%d)\n", ret); |
| |
| return 0; |
| } |
| |
| static struct platform_driver cros_pchg_driver = { |
| .driver = { |
| .name = DRV_NAME, |
| }, |
| .probe = cros_pchg_probe |
| }; |
| |
| module_platform_driver(cros_pchg_driver); |
| |
| MODULE_LICENSE("GPL"); |
| MODULE_DESCRIPTION("ChromeOS EC peripheral device charger"); |