| Broadcom BCM53573 ILP clock |
| =========================== |
| |
| This binding uses the common clock binding: |
| Documentation/devicetree/bindings/clock/clock-bindings.txt |
| |
| This binding is used for ILP clock (sometimes referred as "slow clock") |
| on Broadcom BCM53573 devices using Cortex-A7 CPU. |
| |
| ILP's rate has to be calculated on runtime and it depends on ALP clock |
| which has to be referenced. |
| |
| This clock is part of PMU (Power Management Unit), a Broadcom's device |
| handing power-related aspects. Its node must be sub-node of the PMU |
| device. |
| |
| Required properties: |
| - compatible: "brcm,bcm53573-ilp" |
| - clocks: has to reference an ALP clock |
| - #clock-cells: should be <0> |
| - clock-output-names: from common clock bindings, should contain clock |
| name |
| |
| Example: |
| |
| pmu@18012000 { |
| compatible = "simple-mfd", "syscon"; |
| reg = <0x18012000 0x00001000>; |
| |
| ilp { |
| compatible = "brcm,bcm53573-ilp"; |
| clocks = <&alp>; |
| #clock-cells = <0>; |
| clock-output-names = "ilp"; |
| }; |
| }; |