blob: 63633bdea7e40ea84aca7954a2d671a5d9163ad8 [file] [log] [blame]
DT bindings for the R-Mobile/R-Car interrupt controller
Required properties:
- compatible: has to be "renesas,irqc-<soctype>", "renesas,irqc" as fallback.
Examples with soctypes are:
- "renesas,irqc-r8a73a4" (R-Mobile APE6)
- "renesas,irqc-r8a7790" (R-Car H2)
- "renesas,irqc-r8a7791" (R-Car M2-W)
- "renesas,irqc-r8a7792" (R-Car V2H)
- "renesas,irqc-r8a7793" (R-Car M2-N)
- "renesas,irqc-r8a7794" (R-Car E2)
- #interrupt-cells: has to be <2>: an interrupt index and flags, as defined in
interrupts.txt in this directory
- clocks: Must contain a reference to the functional clock.
Optional properties:
- any properties, listed in interrupts.txt, and any standard resource allocation
properties
Example:
irqc0: interrupt-controller@e61c0000 {
compatible = "renesas,irqc-r8a7790", "renesas,irqc";
#interrupt-cells = <2>;
interrupt-controller;
reg = <0 0xe61c0000 0 0x200>;
interrupts = <0 0 IRQ_TYPE_LEVEL_HIGH>,
<0 1 IRQ_TYPE_LEVEL_HIGH>,
<0 2 IRQ_TYPE_LEVEL_HIGH>,
<0 3 IRQ_TYPE_LEVEL_HIGH>;
clocks = <&mstp4_clks R8A7790_CLK_IRQC>;
};