| Adjunct Processor (AP) facility |
| =============================== |
| |
| |
| Introduction |
| ============ |
| The Adjunct Processor (AP) facility is an IBM Z cryptographic facility comprised |
| of three AP instructions and from 1 up to 256 PCIe cryptographic adapter cards. |
| The AP devices provide cryptographic functions to all CPUs assigned to a |
| linux system running in an IBM Z system LPAR. |
| |
| The AP adapter cards are exposed via the AP bus. The motivation for vfio-ap |
| is to make AP cards available to KVM guests using the VFIO mediated device |
| framework. This implementation relies considerably on the s390 virtualization |
| facilities which do most of the hard work of providing direct access to AP |
| devices. |
| |
| AP Architectural Overview |
| ========================= |
| To facilitate the comprehension of the design, let's start with some |
| definitions: |
| |
| * AP adapter |
| |
| An AP adapter is an IBM Z adapter card that can perform cryptographic |
| functions. There can be from 0 to 256 adapters assigned to an LPAR. Adapters |
| assigned to the LPAR in which a linux host is running will be available to |
| the linux host. Each adapter is identified by a number from 0 to 255; however, |
| the maximum adapter number is determined by machine model and/or adapter type. |
| When installed, an AP adapter is accessed by AP instructions executed by any |
| CPU. |
| |
| The AP adapter cards are assigned to a given LPAR via the system's Activation |
| Profile which can be edited via the HMC. When the linux host system is IPL'd |
| in the LPAR, the AP bus detects the AP adapter cards assigned to the LPAR and |
| creates a sysfs device for each assigned adapter. For example, if AP adapters |
| 4 and 10 (0x0a) are assigned to the LPAR, the AP bus will create the following |
| sysfs device entries:: |
| |
| /sys/devices/ap/card04 |
| /sys/devices/ap/card0a |
| |
| Symbolic links to these devices will also be created in the AP bus devices |
| sub-directory:: |
| |
| /sys/bus/ap/devices/[card04] |
| /sys/bus/ap/devices/[card04] |
| |
| * AP domain |
| |
| An adapter is partitioned into domains. An adapter can hold up to 256 domains |
| depending upon the adapter type and hardware configuration. A domain is |
| identified by a number from 0 to 255; however, the maximum domain number is |
| determined by machine model and/or adapter type.. A domain can be thought of |
| as a set of hardware registers and memory used for processing AP commands. A |
| domain can be configured with a secure private key used for clear key |
| encryption. A domain is classified in one of two ways depending upon how it |
| may be accessed: |
| |
| * Usage domains are domains that are targeted by an AP instruction to |
| process an AP command. |
| |
| * Control domains are domains that are changed by an AP command sent to a |
| usage domain; for example, to set the secure private key for the control |
| domain. |
| |
| The AP usage and control domains are assigned to a given LPAR via the system's |
| Activation Profile which can be edited via the HMC. When a linux host system |
| is IPL'd in the LPAR, the AP bus module detects the AP usage and control |
| domains assigned to the LPAR. The domain number of each usage domain and |
| adapter number of each AP adapter are combined to create AP queue devices |
| (see AP Queue section below). The domain number of each control domain will be |
| represented in a bitmask and stored in a sysfs file |
| /sys/bus/ap/ap_control_domain_mask. The bits in the mask, from most to least |
| significant bit, correspond to domains 0-255. |
| |
| * AP Queue |
| |
| An AP queue is the means by which an AP command is sent to a usage domain |
| inside a specific adapter. An AP queue is identified by a tuple |
| comprised of an AP adapter ID (APID) and an AP queue index (APQI). The |
| APQI corresponds to a given usage domain number within the adapter. This tuple |
| forms an AP Queue Number (APQN) uniquely identifying an AP queue. AP |
| instructions include a field containing the APQN to identify the AP queue to |
| which the AP command is to be sent for processing. |
| |
| The AP bus will create a sysfs device for each APQN that can be derived from |
| the cross product of the AP adapter and usage domain numbers detected when the |
| AP bus module is loaded. For example, if adapters 4 and 10 (0x0a) and usage |
| domains 6 and 71 (0x47) are assigned to the LPAR, the AP bus will create the |
| following sysfs entries:: |
| |
| /sys/devices/ap/card04/04.0006 |
| /sys/devices/ap/card04/04.0047 |
| /sys/devices/ap/card0a/0a.0006 |
| /sys/devices/ap/card0a/0a.0047 |
| |
| The following symbolic links to these devices will be created in the AP bus |
| devices subdirectory:: |
| |
| /sys/bus/ap/devices/[04.0006] |
| /sys/bus/ap/devices/[04.0047] |
| /sys/bus/ap/devices/[0a.0006] |
| /sys/bus/ap/devices/[0a.0047] |
| |
| * AP Instructions: |
| |
| There are three AP instructions: |
| |
| * NQAP: to enqueue an AP command-request message to a queue |
| * DQAP: to dequeue an AP command-reply message from a queue |
| * PQAP: to administer the queues |
| |
| AP instructions identify the domain that is targeted to process the AP |
| command; this must be one of the usage domains. An AP command may modify a |
| domain that is not one of the usage domains, but the modified domain |
| must be one of the control domains. |
| |
| AP and SIE |
| ========== |
| Let's now take a look at how AP instructions executed on a guest are interpreted |
| by the hardware. |
| |
| A satellite control block called the Crypto Control Block (CRYCB) is attached to |
| our main hardware virtualization control block. The CRYCB contains an AP Control |
| Block (APCB) that has three fields to identify the adapters, usage domains and |
| control domains assigned to the KVM guest: |
| |
| * The AP Mask (APM) field is a bit mask that identifies the AP adapters assigned |
| to the KVM guest. Each bit in the mask, from left to right, corresponds to |
| an APID from 0-255. If a bit is set, the corresponding adapter is valid for |
| use by the KVM guest. |
| |
| * The AP Queue Mask (AQM) field is a bit mask identifying the AP usage domains |
| assigned to the KVM guest. Each bit in the mask, from left to right, |
| corresponds to an AP queue index (APQI) from 0-255. If a bit is set, the |
| corresponding queue is valid for use by the KVM guest. |
| |
| * The AP Domain Mask field is a bit mask that identifies the AP control domains |
| assigned to the KVM guest. The ADM bit mask controls which domains can be |
| changed by an AP command-request message sent to a usage domain from the |
| guest. Each bit in the mask, from left to right, corresponds to a domain from |
| 0-255. If a bit is set, the corresponding domain can be modified by an AP |
| command-request message sent to a usage domain. |
| |
| If you recall from the description of an AP Queue, AP instructions include |
| an APQN to identify the AP queue to which an AP command-request message is to be |
| sent (NQAP and PQAP instructions), or from which a command-reply message is to |
| be received (DQAP instruction). The validity of an APQN is defined by the matrix |
| calculated from the APM and AQM; it is the Cartesian product of all assigned |
| adapter numbers (APM) with all assigned queue indexes (AQM). For example, if |
| adapters 1 and 2 and usage domains 5 and 6 are assigned to a guest, the APQNs |
| (1,5), (1,6), (2,5) and (2,6) will be valid for the guest. |
| |
| The APQNs can provide secure key functionality - i.e., a private key is stored |
| on the adapter card for each of its domains - so each APQN must be assigned to |
| at most one guest or to the linux host:: |
| |
| Example 1: Valid configuration: |
| ------------------------------ |
| Guest1: adapters 1,2 domains 5,6 |
| Guest2: adapter 1,2 domain 7 |
| |
| This is valid because both guests have a unique set of APQNs: |
| Guest1 has APQNs (1,5), (1,6), (2,5), (2,6); |
| Guest2 has APQNs (1,7), (2,7) |
| |
| Example 2: Valid configuration: |
| ------------------------------ |
| Guest1: adapters 1,2 domains 5,6 |
| Guest2: adapters 3,4 domains 5,6 |
| |
| This is also valid because both guests have a unique set of APQNs: |
| Guest1 has APQNs (1,5), (1,6), (2,5), (2,6); |
| Guest2 has APQNs (3,5), (3,6), (4,5), (4,6) |
| |
| Example 3: Invalid configuration: |
| -------------------------------- |
| Guest1: adapters 1,2 domains 5,6 |
| Guest2: adapter 1 domains 6,7 |
| |
| This is an invalid configuration because both guests have access to |
| APQN (1,6). |
| |
| The Design |
| ========== |
| The design introduces three new objects: |
| |
| 1. AP matrix device |
| 2. VFIO AP device driver (vfio_ap.ko) |
| 3. VFIO AP mediated pass-through device |
| |
| The VFIO AP device driver |
| ------------------------- |
| The VFIO AP (vfio_ap) device driver serves the following purposes: |
| |
| 1. Provides the interfaces to secure APQNs for exclusive use of KVM guests. |
| |
| 2. Sets up the VFIO mediated device interfaces to manage a vfio_ap mediated |
| device and creates the sysfs interfaces for assigning adapters, usage |
| domains, and control domains comprising the matrix for a KVM guest. |
| |
| 3. Configures the APM, AQM and ADM in the APCB contained in the CRYCB referenced |
| by a KVM guest's SIE state description to grant the guest access to a matrix |
| of AP devices |
| |
| Reserve APQNs for exclusive use of KVM guests |
| --------------------------------------------- |
| The following block diagram illustrates the mechanism by which APQNs are |
| reserved:: |
| |
| +------------------+ |
| 7 remove | | |
| +--------------------> cex4queue driver | |
| | | | |
| | +------------------+ |
| | |
| | |
| | +------------------+ +----------------+ |
| | 5 register driver | | 3 create | | |
| | +----------------> Device core +----------> matrix device | |
| | | | | | | |
| | | +--------^---------+ +----------------+ |
| | | | |
| | | +-------------------+ |
| | | +-----------------------------------+ | |
| | | | 4 register AP driver | | 2 register device |
| | | | | | |
| +--------+---+-v---+ +--------+-------+-+ |
| | | | | |
| | ap_bus +--------------------- > vfio_ap driver | |
| | | 8 probe | | |
| +--------^---------+ +--^--^------------+ |
| 6 edit | | | |
| apmask | +-----------------------------+ | 11 mdev create |
| aqmask | | 1 modprobe | |
| +--------+-----+---+ +----------------+-+ +----------------+ |
| | | | |10 create| mediated | |
| | admin | | VFIO device core |---------> matrix | |
| | + | | | device | |
| +------+-+---------+ +--------^---------+ +--------^-------+ |
| | | | | |
| | | 9 create vfio_ap-passthrough | | |
| | +------------------------------+ | |
| +-------------------------------------------------------------+ |
| 12 assign adapter/domain/control domain |
| |
| The process for reserving an AP queue for use by a KVM guest is: |
| |
| 1. The administrator loads the vfio_ap device driver |
| 2. The vfio-ap driver during its initialization will register a single 'matrix' |
| device with the device core. This will serve as the parent device for |
| all vfio_ap mediated devices used to configure an AP matrix for a guest. |
| 3. The /sys/devices/vfio_ap/matrix device is created by the device core |
| 4. The vfio_ap device driver will register with the AP bus for AP queue devices |
| of type 10 and higher (CEX4 and newer). The driver will provide the vfio_ap |
| driver's probe and remove callback interfaces. Devices older than CEX4 queues |
| are not supported to simplify the implementation by not needlessly |
| complicating the design by supporting older devices that will go out of |
| service in the relatively near future, and for which there are few older |
| systems around on which to test. |
| 5. The AP bus registers the vfio_ap device driver with the device core |
| 6. The administrator edits the AP adapter and queue masks to reserve AP queues |
| for use by the vfio_ap device driver. |
| 7. The AP bus removes the AP queues reserved for the vfio_ap driver from the |
| default zcrypt cex4queue driver. |
| 8. The AP bus probes the vfio_ap device driver to bind the queues reserved for |
| it. |
| 9. The administrator creates a passthrough type vfio_ap mediated device to be |
| used by a guest |
| 10. The administrator assigns the adapters, usage domains and control domains |
| to be exclusively used by a guest. |
| |
| Set up the VFIO mediated device interfaces |
| ------------------------------------------ |
| The VFIO AP device driver utilizes the common interfaces of the VFIO mediated |
| device core driver to: |
| |
| * Register an AP mediated bus driver to add a vfio_ap mediated device to and |
| remove it from a VFIO group. |
| * Create and destroy a vfio_ap mediated device |
| * Add a vfio_ap mediated device to and remove it from the AP mediated bus driver |
| * Add a vfio_ap mediated device to and remove it from an IOMMU group |
| |
| The following high-level block diagram shows the main components and interfaces |
| of the VFIO AP mediated device driver:: |
| |
| +-------------+ |
| | | |
| | +---------+ | mdev_register_driver() +--------------+ |
| | | Mdev | +<-----------------------+ | |
| | | bus | | | vfio_mdev.ko | |
| | | driver | +----------------------->+ |<-> VFIO user |
| | +---------+ | probe()/remove() +--------------+ APIs |
| | | |
| | MDEV CORE | |
| | MODULE | |
| | mdev.ko | |
| | +---------+ | mdev_register_parent() +--------------+ |
| | |Physical | +<-----------------------+ | |
| | | device | | | vfio_ap.ko |<-> matrix |
| | |interface| +----------------------->+ | device |
| | +---------+ | callback +--------------+ |
| +-------------+ |
| |
| During initialization of the vfio_ap module, the matrix device is registered |
| with an 'mdev_parent_ops' structure that provides the sysfs attribute |
| structures, mdev functions and callback interfaces for managing the mediated |
| matrix device. |
| |
| * sysfs attribute structures: |
| |
| supported_type_groups |
| The VFIO mediated device framework supports creation of user-defined |
| mediated device types. These mediated device types are specified |
| via the 'supported_type_groups' structure when a device is registered |
| with the mediated device framework. The registration process creates the |
| sysfs structures for each mediated device type specified in the |
| 'mdev_supported_types' sub-directory of the device being registered. Along |
| with the device type, the sysfs attributes of the mediated device type are |
| provided. |
| |
| The VFIO AP device driver will register one mediated device type for |
| passthrough devices: |
| |
| /sys/devices/vfio_ap/matrix/mdev_supported_types/vfio_ap-passthrough |
| |
| Only the read-only attributes required by the VFIO mdev framework will |
| be provided:: |
| |
| ... name |
| ... device_api |
| ... available_instances |
| ... device_api |
| |
| Where: |
| |
| * name: |
| specifies the name of the mediated device type |
| * device_api: |
| the mediated device type's API |
| * available_instances: |
| the number of vfio_ap mediated passthrough devices |
| that can be created |
| * device_api: |
| specifies the VFIO API |
| mdev_attr_groups |
| This attribute group identifies the user-defined sysfs attributes of the |
| mediated device. When a device is registered with the VFIO mediated device |
| framework, the sysfs attribute files identified in the 'mdev_attr_groups' |
| structure will be created in the vfio_ap mediated device's directory. The |
| sysfs attributes for a vfio_ap mediated device are: |
| |
| assign_adapter / unassign_adapter: |
| Write-only attributes for assigning/unassigning an AP adapter to/from the |
| vfio_ap mediated device. To assign/unassign an adapter, the APID of the |
| adapter is echoed into the respective attribute file. |
| assign_domain / unassign_domain: |
| Write-only attributes for assigning/unassigning an AP usage domain to/from |
| the vfio_ap mediated device. To assign/unassign a domain, the domain |
| number of the usage domain is echoed into the respective attribute |
| file. |
| matrix: |
| A read-only file for displaying the APQNs derived from the Cartesian |
| product of the adapter and domain numbers assigned to the vfio_ap mediated |
| device. |
| guest_matrix: |
| A read-only file for displaying the APQNs derived from the Cartesian |
| product of the adapter and domain numbers assigned to the APM and AQM |
| fields respectively of the KVM guest's CRYCB. This may differ from the |
| the APQNs assigned to the vfio_ap mediated device if any APQN does not |
| reference a queue device bound to the vfio_ap device driver (i.e., the |
| queue is not in the host's AP configuration). |
| assign_control_domain / unassign_control_domain: |
| Write-only attributes for assigning/unassigning an AP control domain |
| to/from the vfio_ap mediated device. To assign/unassign a control domain, |
| the ID of the domain to be assigned/unassigned is echoed into the |
| respective attribute file. |
| control_domains: |
| A read-only file for displaying the control domain numbers assigned to the |
| vfio_ap mediated device. |
| ap_config: |
| A read/write file that, when written to, allows all three of the |
| vfio_ap mediated device's ap matrix masks to be replaced in one shot. |
| Three masks are given, one for adapters, one for domains, and one for |
| control domains. If the given state cannot be set then no changes are |
| made to the vfio-ap mediated device. |
| |
| The format of the data written to ap_config is as follows: |
| {amask},{dmask},{cmask}\n |
| |
| \n is a newline character. |
| |
| amask, dmask, and cmask are masks identifying which adapters, domains, |
| and control domains should be assigned to the mediated device. |
| |
| The format of a mask is as follows: |
| 0xNN..NN |
| |
| Where NN..NN is 64 hexadecimal characters representing a 256-bit value. |
| The leftmost (highest order) bit represents adapter/domain 0. |
| |
| For an example set of masks that represent your mdev's current |
| configuration, simply cat ap_config. |
| |
| Setting an adapter or domain number greater than the maximum allowed for |
| the system will result in an error. |
| |
| This attribute is intended to be used by automation. End users would be |
| better served using the respective assign/unassign attributes for |
| adapters, domains, and control domains. |
| |
| * functions: |
| |
| create: |
| allocates the ap_matrix_mdev structure used by the vfio_ap driver to: |
| |
| * Store the reference to the KVM structure for the guest using the mdev |
| * Store the AP matrix configuration for the adapters, domains, and control |
| domains assigned via the corresponding sysfs attributes files |
| * Store the AP matrix configuration for the adapters, domains and control |
| domains available to a guest. A guest may not be provided access to APQNs |
| referencing queue devices that do not exist, or are not bound to the |
| vfio_ap device driver. |
| |
| remove: |
| deallocates the vfio_ap mediated device's ap_matrix_mdev structure. |
| This will be allowed only if a running guest is not using the mdev. |
| |
| * callback interfaces |
| |
| open_device: |
| The vfio_ap driver uses this callback to register a |
| VFIO_GROUP_NOTIFY_SET_KVM notifier callback function for the matrix mdev |
| devices. The open_device callback is invoked by userspace to connect the |
| VFIO iommu group for the matrix mdev device to the MDEV bus. Access to the |
| KVM structure used to configure the KVM guest is provided via this callback. |
| The KVM structure, is used to configure the guest's access to the AP matrix |
| defined via the vfio_ap mediated device's sysfs attribute files. |
| |
| close_device: |
| unregisters the VFIO_GROUP_NOTIFY_SET_KVM notifier callback function for the |
| matrix mdev device and deconfigures the guest's AP matrix. |
| |
| ioctl: |
| this callback handles the VFIO_DEVICE_GET_INFO and VFIO_DEVICE_RESET ioctls |
| defined by the vfio framework. |
| |
| Configure the guest's AP resources |
| ---------------------------------- |
| Configuring the AP resources for a KVM guest will be performed when the |
| VFIO_GROUP_NOTIFY_SET_KVM notifier callback is invoked. The notifier |
| function is called when userspace connects to KVM. The guest's AP resources are |
| configured via its APCB by: |
| |
| * Setting the bits in the APM corresponding to the APIDs assigned to the |
| vfio_ap mediated device via its 'assign_adapter' interface. |
| * Setting the bits in the AQM corresponding to the domains assigned to the |
| vfio_ap mediated device via its 'assign_domain' interface. |
| * Setting the bits in the ADM corresponding to the domain dIDs assigned to the |
| vfio_ap mediated device via its 'assign_control_domains' interface. |
| |
| The linux device model precludes passing a device through to a KVM guest that |
| is not bound to the device driver facilitating its pass-through. Consequently, |
| an APQN that does not reference a queue device bound to the vfio_ap device |
| driver will not be assigned to a KVM guest's matrix. The AP architecture, |
| however, does not provide a means to filter individual APQNs from the guest's |
| matrix, so the adapters, domains and control domains assigned to vfio_ap |
| mediated device via its sysfs 'assign_adapter', 'assign_domain' and |
| 'assign_control_domain' interfaces will be filtered before providing the AP |
| configuration to a guest: |
| |
| * The APIDs of the adapters, the APQIs of the domains and the domain numbers of |
| the control domains assigned to the matrix mdev that are not also assigned to |
| the host's AP configuration will be filtered. |
| |
| * Each APQN derived from the Cartesian product of the APIDs and APQIs assigned |
| to the vfio_ap mdev is examined and if any one of them does not reference a |
| queue device bound to the vfio_ap device driver, the adapter will not be |
| plugged into the guest (i.e., the bit corresponding to its APID will not be |
| set in the APM of the guest's APCB). |
| |
| The CPU model features for AP |
| ----------------------------- |
| The AP stack relies on the presence of the AP instructions as well as three |
| facilities: The AP Facilities Test (APFT) facility; the AP Query |
| Configuration Information (QCI) facility; and the AP Queue Interruption Control |
| facility. These features/facilities are made available to a KVM guest via the |
| following CPU model features: |
| |
| 1. ap: Indicates whether the AP instructions are installed on the guest. This |
| feature will be enabled by KVM only if the AP instructions are installed |
| on the host. |
| |
| 2. apft: Indicates the APFT facility is available on the guest. This facility |
| can be made available to the guest only if it is available on the host (i.e., |
| facility bit 15 is set). |
| |
| 3. apqci: Indicates the AP QCI facility is available on the guest. This facility |
| can be made available to the guest only if it is available on the host (i.e., |
| facility bit 12 is set). |
| |
| 4. apqi: Indicates AP Queue Interruption Control faclity is available on the |
| guest. This facility can be made available to the guest only if it is |
| available on the host (i.e., facility bit 65 is set). |
| |
| Note: If the user chooses to specify a CPU model different than the 'host' |
| model to QEMU, the CPU model features and facilities need to be turned on |
| explicitly; for example:: |
| |
| /usr/bin/qemu-system-s390x ... -cpu z13,ap=on,apqci=on,apft=on,apqi=on |
| |
| A guest can be precluded from using AP features/facilities by turning them off |
| explicitly; for example:: |
| |
| /usr/bin/qemu-system-s390x ... -cpu host,ap=off,apqci=off,apft=off,apqi=off |
| |
| Note: If the APFT facility is turned off (apft=off) for the guest, the guest |
| will not see any AP devices. The zcrypt device drivers on the guest that |
| register for type 10 and newer AP devices - i.e., the cex4card and cex4queue |
| device drivers - need the APFT facility to ascertain the facilities installed on |
| a given AP device. If the APFT facility is not installed on the guest, then no |
| adapter or domain devices will get created by the AP bus running on the |
| guest because only type 10 and newer devices can be configured for guest use. |
| |
| Example |
| ======= |
| Let's now provide an example to illustrate how KVM guests may be given |
| access to AP facilities. For this example, we will show how to configure |
| three guests such that executing the lszcrypt command on the guests would |
| look like this: |
| |
| Guest1 |
| ------ |
| =========== ===== ============ |
| CARD.DOMAIN TYPE MODE |
| =========== ===== ============ |
| 05 CEX5C CCA-Coproc |
| 05.0004 CEX5C CCA-Coproc |
| 05.00ab CEX5C CCA-Coproc |
| 06 CEX5A Accelerator |
| 06.0004 CEX5A Accelerator |
| 06.00ab CEX5A Accelerator |
| =========== ===== ============ |
| |
| Guest2 |
| ------ |
| =========== ===== ============ |
| CARD.DOMAIN TYPE MODE |
| =========== ===== ============ |
| 05 CEX5C CCA-Coproc |
| 05.0047 CEX5C CCA-Coproc |
| 05.00ff CEX5C CCA-Coproc |
| =========== ===== ============ |
| |
| Guest3 |
| ------ |
| =========== ===== ============ |
| CARD.DOMAIN TYPE MODE |
| =========== ===== ============ |
| 06 CEX5A Accelerator |
| 06.0047 CEX5A Accelerator |
| 06.00ff CEX5A Accelerator |
| =========== ===== ============ |
| |
| These are the steps: |
| |
| 1. Install the vfio_ap module on the linux host. The dependency chain for the |
| vfio_ap module is: |
| * iommu |
| * s390 |
| * zcrypt |
| * vfio |
| * vfio_mdev |
| * vfio_mdev_device |
| * KVM |
| |
| To build the vfio_ap module, the kernel build must be configured with the |
| following Kconfig elements selected: |
| * IOMMU_SUPPORT |
| * S390 |
| * AP |
| * VFIO |
| * KVM |
| |
| If using make menuconfig select the following to build the vfio_ap module:: |
| |
| -> Device Drivers |
| -> IOMMU Hardware Support |
| select S390 AP IOMMU Support |
| -> VFIO Non-Privileged userspace driver framework |
| -> Mediated device driver frramework |
| -> VFIO driver for Mediated devices |
| -> I/O subsystem |
| -> VFIO support for AP devices |
| |
| 2. Secure the AP queues to be used by the three guests so that the host can not |
| access them. To secure them, there are two sysfs files that specify |
| bitmasks marking a subset of the APQN range as usable only by the default AP |
| queue device drivers. All remaining APQNs are available for use by |
| any other device driver. The vfio_ap device driver is currently the only |
| non-default device driver. The location of the sysfs files containing the |
| masks are:: |
| |
| /sys/bus/ap/apmask |
| /sys/bus/ap/aqmask |
| |
| The 'apmask' is a 256-bit mask that identifies a set of AP adapter IDs |
| (APID). Each bit in the mask, from left to right, corresponds to an APID from |
| 0-255. If a bit is set, the APID belongs to the subset of APQNs marked as |
| available only to the default AP queue device drivers. |
| |
| The 'aqmask' is a 256-bit mask that identifies a set of AP queue indexes |
| (APQI). Each bit in the mask, from left to right, corresponds to an APQI from |
| 0-255. If a bit is set, the APQI belongs to the subset of APQNs marked as |
| available only to the default AP queue device drivers. |
| |
| The Cartesian product of the APIDs corresponding to the bits set in the |
| apmask and the APQIs corresponding to the bits set in the aqmask comprise |
| the subset of APQNs that can be used only by the host default device drivers. |
| All other APQNs are available to the non-default device drivers such as the |
| vfio_ap driver. |
| |
| Take, for example, the following masks:: |
| |
| apmask: |
| 0x7d00000000000000000000000000000000000000000000000000000000000000 |
| |
| aqmask: |
| 0x8000000000000000000000000000000000000000000000000000000000000000 |
| |
| The masks indicate: |
| |
| * Adapters 1, 2, 3, 4, 5, and 7 are available for use by the host default |
| device drivers. |
| |
| * Domain 0 is available for use by the host default device drivers |
| |
| * The subset of APQNs available for use only by the default host device |
| drivers are: |
| |
| (1,0), (2,0), (3,0), (4.0), (5,0) and (7,0) |
| |
| * All other APQNs are available for use by the non-default device drivers. |
| |
| The APQN of each AP queue device assigned to the linux host is checked by the |
| AP bus against the set of APQNs derived from the Cartesian product of APIDs |
| and APQIs marked as available to the default AP queue device drivers. If a |
| match is detected, only the default AP queue device drivers will be probed; |
| otherwise, the vfio_ap device driver will be probed. |
| |
| By default, the two masks are set to reserve all APQNs for use by the default |
| AP queue device drivers. There are two ways the default masks can be changed: |
| |
| 1. The sysfs mask files can be edited by echoing a string into the |
| respective sysfs mask file in one of two formats: |
| |
| * An absolute hex string starting with 0x - like "0x12345678" - sets |
| the mask. If the given string is shorter than the mask, it is padded |
| with 0s on the right; for example, specifying a mask value of 0x41 is |
| the same as specifying:: |
| |
| 0x4100000000000000000000000000000000000000000000000000000000000000 |
| |
| Keep in mind that the mask reads from left to right, so the mask |
| above identifies device numbers 1 and 7 (01000001). |
| |
| If the string is longer than the mask, the operation is terminated with |
| an error (EINVAL). |
| |
| * Individual bits in the mask can be switched on and off by specifying |
| each bit number to be switched in a comma separated list. Each bit |
| number string must be prepended with a ('+') or minus ('-') to indicate |
| the corresponding bit is to be switched on ('+') or off ('-'). Some |
| valid values are: |
| |
| - "+0" switches bit 0 on |
| - "-13" switches bit 13 off |
| - "+0x41" switches bit 65 on |
| - "-0xff" switches bit 255 off |
| |
| The following example: |
| |
| +0,-6,+0x47,-0xf0 |
| |
| Switches bits 0 and 71 (0x47) on |
| |
| Switches bits 6 and 240 (0xf0) off |
| |
| Note that the bits not specified in the list remain as they were before |
| the operation. |
| |
| 2. The masks can also be changed at boot time via parameters on the kernel |
| command line like this: |
| |
| ap.apmask=0xffff ap.aqmask=0x40 |
| |
| This would create the following masks:: |
| |
| apmask: |
| 0xffff000000000000000000000000000000000000000000000000000000000000 |
| |
| aqmask: |
| 0x4000000000000000000000000000000000000000000000000000000000000000 |
| |
| Resulting in these two pools:: |
| |
| default drivers pool: adapter 0-15, domain 1 |
| alternate drivers pool: adapter 16-255, domains 0, 2-255 |
| |
| **Note:** |
| Changing a mask such that one or more APQNs will be taken from a vfio_ap |
| mediated device (see below) will fail with an error (EBUSY). A message |
| is logged to the kernel ring buffer which can be viewed with the 'dmesg' |
| command. The output identifies each APQN flagged as 'in use' and identifies |
| the vfio_ap mediated device to which it is assigned; for example: |
| |
| Userspace may not re-assign queue 05.0054 already assigned to 62177883-f1bb-47f0-914d-32a22e3a8804 |
| Userspace may not re-assign queue 04.0054 already assigned to cef03c3c-903d-4ecc-9a83-40694cb8aee4 |
| |
| Securing the APQNs for our example |
| ---------------------------------- |
| To secure the AP queues 05.0004, 05.0047, 05.00ab, 05.00ff, 06.0004, 06.0047, |
| 06.00ab, and 06.00ff for use by the vfio_ap device driver, the corresponding |
| APQNs can be removed from the default masks using either of the following |
| commands:: |
| |
| echo -5,-6 > /sys/bus/ap/apmask |
| |
| echo -4,-0x47,-0xab,-0xff > /sys/bus/ap/aqmask |
| |
| Or the masks can be set as follows:: |
| |
| echo 0xf9ffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffff \ |
| > apmask |
| |
| echo 0xf7fffffffffffffffeffffffffffffffffffffffffeffffffffffffffffffffe \ |
| > aqmask |
| |
| This will result in AP queues 05.0004, 05.0047, 05.00ab, 05.00ff, 06.0004, |
| 06.0047, 06.00ab, and 06.00ff getting bound to the vfio_ap device driver. The |
| sysfs directory for the vfio_ap device driver will now contain symbolic links |
| to the AP queue devices bound to it:: |
| |
| /sys/bus/ap |
| ... [drivers] |
| ...... [vfio_ap] |
| ......... [05.0004] |
| ......... [05.0047] |
| ......... [05.00ab] |
| ......... [05.00ff] |
| ......... [06.0004] |
| ......... [06.0047] |
| ......... [06.00ab] |
| ......... [06.00ff] |
| |
| Keep in mind that only type 10 and newer adapters (i.e., CEX4 and later) |
| can be bound to the vfio_ap device driver. The reason for this is to |
| simplify the implementation by not needlessly complicating the design by |
| supporting older devices that will go out of service in the relatively near |
| future and for which there are few older systems on which to test. |
| |
| The administrator, therefore, must take care to secure only AP queues that |
| can be bound to the vfio_ap device driver. The device type for a given AP |
| queue device can be read from the parent card's sysfs directory. For example, |
| to see the hardware type of the queue 05.0004: |
| |
| cat /sys/bus/ap/devices/card05/hwtype |
| |
| The hwtype must be 10 or higher (CEX4 or newer) in order to be bound to the |
| vfio_ap device driver. |
| |
| 3. Create the mediated devices needed to configure the AP matrixes for the |
| three guests and to provide an interface to the vfio_ap driver for |
| use by the guests:: |
| |
| /sys/devices/vfio_ap/matrix/ |
| --- [mdev_supported_types] |
| ------ [vfio_ap-passthrough] (passthrough vfio_ap mediated device type) |
| --------- create |
| --------- [devices] |
| |
| To create the mediated devices for the three guests:: |
| |
| uuidgen > create |
| uuidgen > create |
| uuidgen > create |
| |
| or |
| |
| echo $uuid1 > create |
| echo $uuid2 > create |
| echo $uuid3 > create |
| |
| This will create three mediated devices in the [devices] subdirectory named |
| after the UUID written to the create attribute file. We call them $uuid1, |
| $uuid2 and $uuid3 and this is the sysfs directory structure after creation:: |
| |
| /sys/devices/vfio_ap/matrix/ |
| --- [mdev_supported_types] |
| ------ [vfio_ap-passthrough] |
| --------- [devices] |
| ------------ [$uuid1] |
| --------------- assign_adapter |
| --------------- assign_control_domain |
| --------------- assign_domain |
| --------------- matrix |
| --------------- unassign_adapter |
| --------------- unassign_control_domain |
| --------------- unassign_domain |
| |
| ------------ [$uuid2] |
| --------------- assign_adapter |
| --------------- assign_control_domain |
| --------------- assign_domain |
| --------------- matrix |
| --------------- unassign_adapter |
| ----------------unassign_control_domain |
| ----------------unassign_domain |
| |
| ------------ [$uuid3] |
| --------------- assign_adapter |
| --------------- assign_control_domain |
| --------------- assign_domain |
| --------------- matrix |
| --------------- unassign_adapter |
| ----------------unassign_control_domain |
| ----------------unassign_domain |
| |
| Note *****: The vfio_ap mdevs do not persist across reboots unless the |
| mdevctl tool is used to create and persist them. |
| |
| 4. The administrator now needs to configure the matrixes for the mediated |
| devices $uuid1 (for Guest1), $uuid2 (for Guest2) and $uuid3 (for Guest3). |
| |
| This is how the matrix is configured for Guest1:: |
| |
| echo 5 > assign_adapter |
| echo 6 > assign_adapter |
| echo 4 > assign_domain |
| echo 0xab > assign_domain |
| |
| Control domains can similarly be assigned using the assign_control_domain |
| sysfs file. |
| |
| If a mistake is made configuring an adapter, domain or control domain, |
| you can use the unassign_xxx files to unassign the adapter, domain or |
| control domain. |
| |
| To display the matrix configuration for Guest1:: |
| |
| cat matrix |
| |
| To display the matrix that is or will be assigned to Guest1:: |
| |
| cat guest_matrix |
| |
| This is how the matrix is configured for Guest2:: |
| |
| echo 5 > assign_adapter |
| echo 0x47 > assign_domain |
| echo 0xff > assign_domain |
| |
| This is how the matrix is configured for Guest3:: |
| |
| echo 6 > assign_adapter |
| echo 0x47 > assign_domain |
| echo 0xff > assign_domain |
| |
| In order to successfully assign an adapter: |
| |
| * The adapter number specified must represent a value from 0 up to the |
| maximum adapter number configured for the system. If an adapter number |
| higher than the maximum is specified, the operation will terminate with |
| an error (ENODEV). |
| |
| Note: The maximum adapter number can be obtained via the sysfs |
| /sys/bus/ap/ap_max_adapter_id attribute file. |
| |
| * Each APQN derived from the Cartesian product of the APID of the adapter |
| being assigned and the APQIs of the domains previously assigned: |
| |
| - Must only be available to the vfio_ap device driver as specified in the |
| sysfs /sys/bus/ap/apmask and /sys/bus/ap/aqmask attribute files. If even |
| one APQN is reserved for use by the host device driver, the operation |
| will terminate with an error (EADDRNOTAVAIL). |
| |
| - Must NOT be assigned to another vfio_ap mediated device. If even one APQN |
| is assigned to another vfio_ap mediated device, the operation will |
| terminate with an error (EBUSY). |
| |
| - Must NOT be assigned while the sysfs /sys/bus/ap/apmask and |
| sys/bus/ap/aqmask attribute files are being edited or the operation may |
| terminate with an error (EBUSY). |
| |
| In order to successfully assign a domain: |
| |
| * The domain number specified must represent a value from 0 up to the |
| maximum domain number configured for the system. If a domain number |
| higher than the maximum is specified, the operation will terminate with |
| an error (ENODEV). |
| |
| Note: The maximum domain number can be obtained via the sysfs |
| /sys/bus/ap/ap_max_domain_id attribute file. |
| |
| * Each APQN derived from the Cartesian product of the APQI of the domain |
| being assigned and the APIDs of the adapters previously assigned: |
| |
| - Must only be available to the vfio_ap device driver as specified in the |
| sysfs /sys/bus/ap/apmask and /sys/bus/ap/aqmask attribute files. If even |
| one APQN is reserved for use by the host device driver, the operation |
| will terminate with an error (EADDRNOTAVAIL). |
| |
| - Must NOT be assigned to another vfio_ap mediated device. If even one APQN |
| is assigned to another vfio_ap mediated device, the operation will |
| terminate with an error (EBUSY). |
| |
| - Must NOT be assigned while the sysfs /sys/bus/ap/apmask and |
| sys/bus/ap/aqmask attribute files are being edited or the operation may |
| terminate with an error (EBUSY). |
| |
| In order to successfully assign a control domain: |
| |
| * The domain number specified must represent a value from 0 up to the maximum |
| domain number configured for the system. If a control domain number higher |
| than the maximum is specified, the operation will terminate with an |
| error (ENODEV). |
| |
| 5. Start Guest1:: |
| |
| /usr/bin/qemu-system-s390x ... -cpu host,ap=on,apqci=on,apft=on,apqi=on \ |
| -device vfio-ap,sysfsdev=/sys/devices/vfio_ap/matrix/$uuid1 ... |
| |
| 7. Start Guest2:: |
| |
| /usr/bin/qemu-system-s390x ... -cpu host,ap=on,apqci=on,apft=on,apqi=on \ |
| -device vfio-ap,sysfsdev=/sys/devices/vfio_ap/matrix/$uuid2 ... |
| |
| 7. Start Guest3:: |
| |
| /usr/bin/qemu-system-s390x ... -cpu host,ap=on,apqci=on,apft=on,apqi=on \ |
| -device vfio-ap,sysfsdev=/sys/devices/vfio_ap/matrix/$uuid3 ... |
| |
| When the guest is shut down, the vfio_ap mediated devices may be removed. |
| |
| Using our example again, to remove the vfio_ap mediated device $uuid1:: |
| |
| /sys/devices/vfio_ap/matrix/ |
| --- [mdev_supported_types] |
| ------ [vfio_ap-passthrough] |
| --------- [devices] |
| ------------ [$uuid1] |
| --------------- remove |
| |
| :: |
| |
| echo 1 > remove |
| |
| This will remove all of the matrix mdev device's sysfs structures including |
| the mdev device itself. To recreate and reconfigure the matrix mdev device, |
| all of the steps starting with step 3 will have to be performed again. Note |
| that the remove will fail if a guest using the vfio_ap mdev is still running. |
| |
| It is not necessary to remove a vfio_ap mdev, but one may want to |
| remove it if no guest will use it during the remaining lifetime of the linux |
| host. If the vfio_ap mdev is removed, one may want to also reconfigure |
| the pool of adapters and queues reserved for use by the default drivers. |
| |
| Hot plug/unplug support: |
| ======================== |
| An adapter, domain or control domain may be hot plugged into a running KVM |
| guest by assigning it to the vfio_ap mediated device being used by the guest if |
| the following conditions are met: |
| |
| * The adapter, domain or control domain must also be assigned to the host's |
| AP configuration. |
| |
| * Each APQN derived from the Cartesian product comprised of the APID of the |
| adapter being assigned and the APQIs of the domains assigned must reference a |
| queue device bound to the vfio_ap device driver. |
| |
| * To hot plug a domain, each APQN derived from the Cartesian product |
| comprised of the APQI of the domain being assigned and the APIDs of the |
| adapters assigned must reference a queue device bound to the vfio_ap device |
| driver. |
| |
| An adapter, domain or control domain may be hot unplugged from a running KVM |
| guest by unassigning it from the vfio_ap mediated device being used by the |
| guest. |
| |
| Over-provisioning of AP queues for a KVM guest: |
| =============================================== |
| Over-provisioning is defined herein as the assignment of adapters or domains to |
| a vfio_ap mediated device that do not reference AP devices in the host's AP |
| configuration. The idea here is that when the adapter or domain becomes |
| available, it will be automatically hot-plugged into the KVM guest using |
| the vfio_ap mediated device to which it is assigned as long as each new APQN |
| resulting from plugging it in references a queue device bound to the vfio_ap |
| device driver. |
| |
| Driver Features |
| =============== |
| The vfio_ap driver exposes a sysfs file containing supported features. |
| This exists so third party tools (like Libvirt and mdevctl) can query the |
| availability of specific features. |
| |
| The features list can be found here: /sys/bus/matrix/devices/matrix/features |
| |
| Entries are space delimited. Each entry consists of a combination of |
| alphanumeric and underscore characters. |
| |
| Example: |
| cat /sys/bus/matrix/devices/matrix/features |
| guest_matrix dyn ap_config |
| |
| the following features are advertised: |
| |
| ---------------+---------------------------------------------------------------+ |
| | Flag | Description | |
| +==============+===============================================================+ |
| | guest_matrix | guest_matrix attribute exists. It reports the matrix of | |
| | | adapters and domains that are or will be passed through to a | |
| | | guest when the mdev is attached to it. | |
| +--------------+---------------------------------------------------------------+ |
| | dyn | Indicates hot plug/unplug of AP adapters, domains and control | |
| | | domains for a guest to which the mdev is attached. | |
| +------------+-----------------------------------------------------------------+ |
| | ap_config | ap_config interface for one-shot modifications to mdev config | |
| +--------------+---------------------------------------------------------------+ |
| |
| Limitations |
| =========== |
| Live guest migration is not supported for guests using AP devices without |
| intervention by a system administrator. Before a KVM guest can be migrated, |
| the vfio_ap mediated device must be removed. Unfortunately, it can not be |
| removed manually (i.e., echo 1 > /sys/devices/vfio_ap/matrix/$UUID/remove) while |
| the mdev is in use by a KVM guest. If the guest is being emulated by QEMU, |
| its mdev can be hot unplugged from the guest in one of two ways: |
| |
| 1. If the KVM guest was started with libvirt, you can hot unplug the mdev via |
| the following commands: |
| |
| virsh detach-device <guestname> <path-to-device-xml> |
| |
| For example, to hot unplug mdev 62177883-f1bb-47f0-914d-32a22e3a8804 from |
| the guest named 'my-guest': |
| |
| virsh detach-device my-guest ~/config/my-guest-hostdev.xml |
| |
| The contents of my-guest-hostdev.xml: |
| |
| .. code-block:: xml |
| |
| <hostdev mode='subsystem' type='mdev' managed='no' model='vfio-ap'> |
| <source> |
| <address uuid='62177883-f1bb-47f0-914d-32a22e3a8804'/> |
| </source> |
| </hostdev> |
| |
| |
| virsh qemu-monitor-command <guest-name> --hmp "device-del <device-id>" |
| |
| For example, to hot unplug the vfio_ap mediated device identified on the |
| qemu command line with 'id=hostdev0' from the guest named 'my-guest': |
| |
| .. code-block:: sh |
| |
| virsh qemu-monitor-command my-guest --hmp "device_del hostdev0" |
| |
| 2. A vfio_ap mediated device can be hot unplugged by attaching the qemu monitor |
| to the guest and using the following qemu monitor command: |
| |
| (QEMU) device-del id=<device-id> |
| |
| For example, to hot unplug the vfio_ap mediated device that was specified |
| on the qemu command line with 'id=hostdev0' when the guest was started: |
| |
| (QEMU) device-del id=hostdev0 |
| |
| After live migration of the KVM guest completes, an AP configuration can be |
| restored to the KVM guest by hot plugging a vfio_ap mediated device on the target |
| system into the guest in one of two ways: |
| |
| 1. If the KVM guest was started with libvirt, you can hot plug a matrix mediated |
| device into the guest via the following virsh commands: |
| |
| virsh attach-device <guestname> <path-to-device-xml> |
| |
| For example, to hot plug mdev 62177883-f1bb-47f0-914d-32a22e3a8804 into |
| the guest named 'my-guest': |
| |
| virsh attach-device my-guest ~/config/my-guest-hostdev.xml |
| |
| The contents of my-guest-hostdev.xml: |
| |
| .. code-block:: xml |
| |
| <hostdev mode='subsystem' type='mdev' managed='no' model='vfio-ap'> |
| <source> |
| <address uuid='62177883-f1bb-47f0-914d-32a22e3a8804'/> |
| </source> |
| </hostdev> |
| |
| |
| virsh qemu-monitor-command <guest-name> --hmp \ |
| "device_add vfio-ap,sysfsdev=<path-to-mdev>,id=<device-id>" |
| |
| For example, to hot plug the vfio_ap mediated device |
| 62177883-f1bb-47f0-914d-32a22e3a8804 into the guest named 'my-guest' with |
| device-id hostdev0: |
| |
| virsh qemu-monitor-command my-guest --hmp \ |
| "device_add vfio-ap,\ |
| sysfsdev=/sys/devices/vfio_ap/matrix/62177883-f1bb-47f0-914d-32a22e3a8804,\ |
| id=hostdev0" |
| |
| 2. A vfio_ap mediated device can be hot plugged by attaching the qemu monitor |
| to the guest and using the following qemu monitor command: |
| |
| (qemu) device_add "vfio-ap,sysfsdev=<path-to-mdev>,id=<device-id>" |
| |
| For example, to plug the vfio_ap mediated device |
| 62177883-f1bb-47f0-914d-32a22e3a8804 into the guest with the device-id |
| hostdev0: |
| |
| (QEMU) device-add "vfio-ap,\ |
| sysfsdev=/sys/devices/vfio_ap/matrix/62177883-f1bb-47f0-914d-32a22e3a8804,\ |
| id=hostdev0" |