| // SPDX-License-Identifier: GPL-2.0-only |
| /* |
| * OPAL Operator Panel Display Driver |
| * |
| * Copyright 2016, Suraj Jitindar Singh, IBM Corporation. |
| */ |
| |
| #define pr_fmt(fmt) KBUILD_MODNAME ": " fmt |
| |
| #include <linux/init.h> |
| #include <linux/module.h> |
| #include <linux/kernel.h> |
| #include <linux/fs.h> |
| #include <linux/device.h> |
| #include <linux/errno.h> |
| #include <linux/mutex.h> |
| #include <linux/of.h> |
| #include <linux/slab.h> |
| #include <linux/platform_device.h> |
| #include <linux/miscdevice.h> |
| |
| #include <asm/opal.h> |
| |
| /* |
| * This driver creates a character device (/dev/op_panel) which exposes the |
| * operator panel (character LCD display) on IBM Power Systems machines |
| * with FSPs. |
| * A character buffer written to the device will be displayed on the |
| * operator panel. |
| */ |
| |
| static DEFINE_MUTEX(oppanel_mutex); |
| |
| static u32 num_lines, oppanel_size; |
| static oppanel_line_t *oppanel_lines; |
| static char *oppanel_data; |
| |
| static loff_t oppanel_llseek(struct file *filp, loff_t offset, int whence) |
| { |
| return fixed_size_llseek(filp, offset, whence, oppanel_size); |
| } |
| |
| static ssize_t oppanel_read(struct file *filp, char __user *userbuf, size_t len, |
| loff_t *f_pos) |
| { |
| return simple_read_from_buffer(userbuf, len, f_pos, oppanel_data, |
| oppanel_size); |
| } |
| |
| static int __op_panel_update_display(void) |
| { |
| struct opal_msg msg; |
| int rc, token; |
| |
| token = opal_async_get_token_interruptible(); |
| if (token < 0) { |
| if (token != -ERESTARTSYS) |
| pr_debug("Couldn't get OPAL async token [token=%d]\n", |
| token); |
| return token; |
| } |
| |
| rc = opal_write_oppanel_async(token, oppanel_lines, num_lines); |
| switch (rc) { |
| case OPAL_ASYNC_COMPLETION: |
| rc = opal_async_wait_response(token, &msg); |
| if (rc) { |
| pr_debug("Failed to wait for async response [rc=%d]\n", |
| rc); |
| break; |
| } |
| rc = opal_get_async_rc(msg); |
| if (rc != OPAL_SUCCESS) { |
| pr_debug("OPAL async call returned failed [rc=%d]\n", |
| rc); |
| break; |
| } |
| case OPAL_SUCCESS: |
| break; |
| default: |
| pr_debug("OPAL write op-panel call failed [rc=%d]\n", rc); |
| } |
| |
| opal_async_release_token(token); |
| return rc; |
| } |
| |
| static ssize_t oppanel_write(struct file *filp, const char __user *userbuf, |
| size_t len, loff_t *f_pos) |
| { |
| loff_t f_pos_prev = *f_pos; |
| ssize_t ret; |
| int rc; |
| |
| if (!*f_pos) |
| memset(oppanel_data, ' ', oppanel_size); |
| else if (*f_pos >= oppanel_size) |
| return -EFBIG; |
| |
| ret = simple_write_to_buffer(oppanel_data, oppanel_size, f_pos, userbuf, |
| len); |
| if (ret > 0) { |
| rc = __op_panel_update_display(); |
| if (rc != OPAL_SUCCESS) { |
| pr_err_ratelimited("OPAL call failed to write to op panel display [rc=%d]\n", |
| rc); |
| *f_pos = f_pos_prev; |
| return -EIO; |
| } |
| } |
| return ret; |
| } |
| |
| static int oppanel_open(struct inode *inode, struct file *filp) |
| { |
| if (!mutex_trylock(&oppanel_mutex)) { |
| pr_debug("Device Busy\n"); |
| return -EBUSY; |
| } |
| return 0; |
| } |
| |
| static int oppanel_release(struct inode *inode, struct file *filp) |
| { |
| mutex_unlock(&oppanel_mutex); |
| return 0; |
| } |
| |
| static const struct file_operations oppanel_fops = { |
| .owner = THIS_MODULE, |
| .llseek = oppanel_llseek, |
| .read = oppanel_read, |
| .write = oppanel_write, |
| .open = oppanel_open, |
| .release = oppanel_release |
| }; |
| |
| static struct miscdevice oppanel_dev = { |
| .minor = MISC_DYNAMIC_MINOR, |
| .name = "op_panel", |
| .fops = &oppanel_fops |
| }; |
| |
| static int oppanel_probe(struct platform_device *pdev) |
| { |
| struct device_node *np = pdev->dev.of_node; |
| u32 line_len; |
| int rc, i; |
| |
| rc = of_property_read_u32(np, "#length", &line_len); |
| if (rc) { |
| pr_err_ratelimited("Operator panel length property not found\n"); |
| return rc; |
| } |
| rc = of_property_read_u32(np, "#lines", &num_lines); |
| if (rc) { |
| pr_err_ratelimited("Operator panel lines property not found\n"); |
| return rc; |
| } |
| oppanel_size = line_len * num_lines; |
| |
| pr_devel("Operator panel of size %u found with %u lines of length %u\n", |
| oppanel_size, num_lines, line_len); |
| |
| oppanel_data = kcalloc(oppanel_size, sizeof(*oppanel_data), GFP_KERNEL); |
| if (!oppanel_data) |
| return -ENOMEM; |
| |
| oppanel_lines = kcalloc(num_lines, sizeof(oppanel_line_t), GFP_KERNEL); |
| if (!oppanel_lines) { |
| rc = -ENOMEM; |
| goto free_oppanel_data; |
| } |
| |
| memset(oppanel_data, ' ', oppanel_size); |
| for (i = 0; i < num_lines; i++) { |
| oppanel_lines[i].line_len = cpu_to_be64(line_len); |
| oppanel_lines[i].line = cpu_to_be64(__pa(&oppanel_data[i * |
| line_len])); |
| } |
| |
| rc = misc_register(&oppanel_dev); |
| if (rc) { |
| pr_err_ratelimited("Failed to register as misc device\n"); |
| goto free_oppanel; |
| } |
| |
| return 0; |
| |
| free_oppanel: |
| kfree(oppanel_lines); |
| free_oppanel_data: |
| kfree(oppanel_data); |
| return rc; |
| } |
| |
| static int oppanel_remove(struct platform_device *pdev) |
| { |
| misc_deregister(&oppanel_dev); |
| kfree(oppanel_lines); |
| kfree(oppanel_data); |
| return 0; |
| } |
| |
| static const struct of_device_id oppanel_match[] = { |
| { .compatible = "ibm,opal-oppanel" }, |
| { }, |
| }; |
| |
| static struct platform_driver oppanel_driver = { |
| .driver = { |
| .name = "powernv-op-panel", |
| .of_match_table = oppanel_match, |
| }, |
| .probe = oppanel_probe, |
| .remove = oppanel_remove, |
| }; |
| |
| module_platform_driver(oppanel_driver); |
| |
| MODULE_DEVICE_TABLE(of, oppanel_match); |
| MODULE_LICENSE("GPL v2"); |
| MODULE_DESCRIPTION("PowerNV Operator Panel LCD Display Driver"); |
| MODULE_AUTHOR("Suraj Jitindar Singh <sjitindarsingh@gmail.com>"); |