| #!/bin/bash | |
| # SPDX-License-Identifier: GPL-2.0 | |
| # Return true if perf_event_paranoid is > $1 and not running as root. | |
| function ParanoidAndNotRoot() | |
| { | |
| [ "$(id -u)" != 0 ] && [ "$(cat /proc/sys/kernel/perf_event_paranoid)" -gt $1 ] | |
| } | |
| # $1 name $2 extra_opt | |
| check_no_args() | |
| { | |
| echo -n "Checking $1 output: no args " | |
| perf stat $2 true | |
| commachecker --no-args | |
| echo "[Success]" | |
| } | |
| check_system_wide() | |
| { | |
| echo -n "Checking $1 output: system wide " | |
| if ParanoidAndNotRoot 0 | |
| then | |
| echo "[Skip] paranoid and not root" | |
| return | |
| fi | |
| perf stat -a $2 true | |
| commachecker --system-wide | |
| echo "[Success]" | |
| } | |
| check_system_wide_no_aggr() | |
| { | |
| echo -n "Checking $1 output: system wide no aggregation " | |
| if ParanoidAndNotRoot 0 | |
| then | |
| echo "[Skip] paranoid and not root" | |
| return | |
| fi | |
| perf stat -A -a --no-merge $2 true | |
| commachecker --system-wide-no-aggr | |
| echo "[Success]" | |
| } | |
| check_interval() | |
| { | |
| echo -n "Checking $1 output: interval " | |
| perf stat -I 1000 $2 true | |
| commachecker --interval | |
| echo "[Success]" | |
| } | |
| check_event() | |
| { | |
| echo -n "Checking $1 output: event " | |
| perf stat -e cpu-clock $2 true | |
| commachecker --event | |
| echo "[Success]" | |
| } | |
| check_per_core() | |
| { | |
| echo -n "Checking $1 output: per core " | |
| if ParanoidAndNotRoot 0 | |
| then | |
| echo "[Skip] paranoid and not root" | |
| return | |
| fi | |
| perf stat --per-core -a $2 true | |
| commachecker --per-core | |
| echo "[Success]" | |
| } | |
| check_per_thread() | |
| { | |
| echo -n "Checking $1 output: per thread " | |
| if ParanoidAndNotRoot 0 | |
| then | |
| echo "[Skip] paranoid and not root" | |
| return | |
| fi | |
| perf stat --per-thread -p $$ $2 true | |
| commachecker --per-thread | |
| echo "[Success]" | |
| } | |
| check_per_cache_instance() | |
| { | |
| echo -n "Checking $1 output: per cache instance " | |
| if ParanoidAndNotRoot 0 | |
| then | |
| echo "[Skip] paranoid and not root" | |
| return | |
| fi | |
| perf stat --per-cache -a $2 true | |
| commachecker --per-cache | |
| echo "[Success]" | |
| } | |
| check_per_cluster() | |
| { | |
| echo -n "Checking $1 output: per cluster " | |
| if ParanoidAndNotRoot 0 | |
| then | |
| echo "[Skip] paranoid and not root" | |
| return | |
| fi | |
| perf stat --per-cluster -a $2 true | |
| echo "[Success]" | |
| } | |
| check_per_die() | |
| { | |
| echo -n "Checking $1 output: per die " | |
| if ParanoidAndNotRoot 0 | |
| then | |
| echo "[Skip] paranoid and not root" | |
| return | |
| fi | |
| perf stat --per-die -a $2 true | |
| commachecker --per-die | |
| echo "[Success]" | |
| } | |
| check_per_node() | |
| { | |
| echo -n "Checking $1 output: per node " | |
| if ParanoidAndNotRoot 0 | |
| then | |
| echo "[Skip] paranoid and not root" | |
| return | |
| fi | |
| perf stat --per-node -a $2 true | |
| commachecker --per-node | |
| echo "[Success]" | |
| } | |
| check_per_socket() | |
| { | |
| echo -n "Checking $1 output: per socket " | |
| if ParanoidAndNotRoot 0 | |
| then | |
| echo "[Skip] paranoid and not root" | |
| return | |
| fi | |
| perf stat --per-socket -a $2 true | |
| commachecker --per-socket | |
| echo "[Success]" | |
| } | |
| check_metric_only() | |
| { | |
| echo -n "Checking $1 output: metric only " | |
| if [ "$(uname -m)" = "s390x" ] && ! grep '^facilities' /proc/cpuinfo | grep -qw 67 | |
| then | |
| echo "[Skip] CPU-measurement counter facility not installed" | |
| return | |
| fi | |
| perf stat --metric-only $2 -M page_faults_per_second true | |
| commachecker --metric-only | |
| echo "[Success]" | |
| } | |
| # The perf stat options for per-socket, per-core, per-die | |
| # and -A ( no_aggr mode ) uses the info fetched from this | |
| # directory: "/sys/devices/system/cpu/cpu*/topology". For | |
| # example, socket value is fetched from "physical_package_id" | |
| # file in topology directory. | |
| # Reference: cpu__get_topology_int in util/cpumap.c | |
| # If the platform doesn't expose topology information, values | |
| # will be set to -1. For example, incase of pSeries platform | |
| # of powerpc, value for "physical_package_id" is restricted | |
| # and set to -1. Check here validates the socket-id read from | |
| # topology file before proceeding further | |
| FILE_LOC="/sys/devices/system/cpu/cpu*/topology/" | |
| FILE_NAME="physical_package_id" | |
| function check_for_topology() | |
| { | |
| if ! ParanoidAndNotRoot 0 | |
| then | |
| socket_file=`ls $FILE_LOC/$FILE_NAME | head -n 1` | |
| [ -z $socket_file ] && { | |
| echo 0 | |
| return | |
| } | |
| socket_id=`cat $socket_file` | |
| [ $socket_id == -1 ] && { | |
| echo 1 | |
| return | |
| } | |
| fi | |
| echo 0 | |
| } |