| // SPDX-License-Identifier: GPL-2.0-only |
| /* |
| * SPI IIO driver for Bosch BMA400 triaxial acceleration sensor. |
| * |
| * Copyright 2020 Dan Robertson <dan@dlrobertson.com> |
| * |
| */ |
| #include <linux/bits.h> |
| #include <linux/init.h> |
| #include <linux/mod_devicetable.h> |
| #include <linux/module.h> |
| #include <linux/regmap.h> |
| #include <linux/spi/spi.h> |
| |
| #include "bma400.h" |
| |
| #define BMA400_MAX_SPI_READ 2 |
| #define BMA400_SPI_READ_BUFFER_SIZE (BMA400_MAX_SPI_READ + 1) |
| |
| static int bma400_regmap_spi_read(void *context, |
| const void *reg, size_t reg_size, |
| void *val, size_t val_size) |
| { |
| struct device *dev = context; |
| struct spi_device *spi = to_spi_device(dev); |
| u8 result[BMA400_SPI_READ_BUFFER_SIZE]; |
| ssize_t status; |
| |
| if (val_size > BMA400_MAX_SPI_READ) |
| return -EINVAL; |
| |
| status = spi_write_then_read(spi, reg, 1, result, val_size + 1); |
| if (status) |
| return status; |
| |
| /* |
| * From the BMA400 datasheet: |
| * |
| * > For a basic read operation two bytes have to be read and the first |
| * > has to be dropped and the second byte must be interpreted. |
| */ |
| memcpy(val, result + 1, val_size); |
| |
| return 0; |
| } |
| |
| static int bma400_regmap_spi_write(void *context, const void *data, |
| size_t count) |
| { |
| struct device *dev = context; |
| struct spi_device *spi = to_spi_device(dev); |
| |
| return spi_write(spi, data, count); |
| } |
| |
| static const struct regmap_bus bma400_regmap_bus = { |
| .read = bma400_regmap_spi_read, |
| .write = bma400_regmap_spi_write, |
| .read_flag_mask = BIT(7), |
| .max_raw_read = BMA400_MAX_SPI_READ, |
| }; |
| |
| static int bma400_spi_probe(struct spi_device *spi) |
| { |
| const struct spi_device_id *id = spi_get_device_id(spi); |
| struct regmap *regmap; |
| unsigned int val; |
| int ret; |
| |
| regmap = devm_regmap_init(&spi->dev, &bma400_regmap_bus, |
| &spi->dev, &bma400_regmap_config); |
| if (IS_ERR(regmap)) { |
| dev_err(&spi->dev, "failed to create regmap\n"); |
| return PTR_ERR(regmap); |
| } |
| |
| /* |
| * Per the bma400 datasheet, the first SPI read may |
| * return garbage. As the datasheet recommends, the |
| * chip ID register will be read here and checked |
| * again in the following probe. |
| */ |
| ret = regmap_read(regmap, BMA400_CHIP_ID_REG, &val); |
| if (ret) |
| dev_err(&spi->dev, "Failed to read chip id register\n"); |
| |
| return bma400_probe(&spi->dev, regmap, spi->irq, id->name); |
| } |
| |
| static const struct spi_device_id bma400_spi_ids[] = { |
| { "bma400", 0 }, |
| { } |
| }; |
| MODULE_DEVICE_TABLE(spi, bma400_spi_ids); |
| |
| static const struct of_device_id bma400_of_spi_match[] = { |
| { .compatible = "bosch,bma400" }, |
| { } |
| }; |
| MODULE_DEVICE_TABLE(of, bma400_of_spi_match); |
| |
| static struct spi_driver bma400_spi_driver = { |
| .driver = { |
| .name = "bma400", |
| .of_match_table = bma400_of_spi_match, |
| }, |
| .probe = bma400_spi_probe, |
| .id_table = bma400_spi_ids, |
| }; |
| |
| module_spi_driver(bma400_spi_driver); |
| MODULE_AUTHOR("Dan Robertson <dan@dlrobertson.com>"); |
| MODULE_DESCRIPTION("Bosch BMA400 triaxial acceleration sensor (SPI)"); |
| MODULE_LICENSE("GPL"); |
| MODULE_IMPORT_NS(IIO_BMA400); |