| * CoreSight Components: |
| |
| CoreSight components are compliant with the ARM CoreSight architecture |
| specification and can be connected in various topologies to suit a particular |
| SoCs tracing needs. These trace components can generally be classified as |
| sinks, links and sources. Trace data produced by one or more sources flows |
| through the intermediate links connecting the source to the currently selected |
| sink. Each CoreSight component device should use these properties to describe |
| its hardware characteristcs. |
| |
| * Required properties for all components *except* non-configurable replicators |
| and non-configurable funnels: |
| |
| * compatible: These have to be supplemented with "arm,primecell" as |
| drivers are using the AMBA bus interface. Possible values include: |
| - Embedded Trace Buffer (version 1.0): |
| "arm,coresight-etb10", "arm,primecell"; |
| |
| - Trace Port Interface Unit: |
| "arm,coresight-tpiu", "arm,primecell"; |
| |
| - Trace Memory Controller, used for Embedded Trace Buffer(ETB), |
| Embedded Trace FIFO(ETF) and Embedded Trace Router(ETR) |
| configuration. The configuration mode (ETB, ETF, ETR) is |
| discovered at boot time when the device is probed. |
| "arm,coresight-tmc", "arm,primecell"; |
| |
| - Trace Programmable Funnel: |
| "arm,coresight-dynamic-funnel", "arm,primecell"; |
| "arm,coresight-funnel", "arm,primecell"; (OBSOLETE. For |
| backward compatibility and will be removed) |
| |
| - Embedded Trace Macrocell (version 3.x) and |
| Program Flow Trace Macrocell: |
| "arm,coresight-etm3x", "arm,primecell"; |
| |
| - Embedded Trace Macrocell (version 4.x), with memory mapped access. |
| "arm,coresight-etm4x", "arm,primecell"; |
| |
| - Embedded Trace Macrocell (version 4.x), with system register access only. |
| "arm,coresight-etm4x-sysreg"; |
| |
| - Coresight programmable Replicator : |
| "arm,coresight-dynamic-replicator", "arm,primecell"; |
| |
| - System Trace Macrocell: |
| "arm,coresight-stm", "arm,primecell"; [1] |
| - Coresight Address Translation Unit (CATU) |
| "arm,coresight-catu", "arm,primecell"; |
| |
| - Coresight Cross Trigger Interface (CTI): |
| "arm,coresight-cti", "arm,primecell"; |
| See coresight-cti.yaml for full CTI definitions. |
| |
| * reg: physical base address and length of the register |
| set(s) of the component. |
| |
| * clocks: the clocks associated to this component. |
| |
| * clock-names: the name of the clocks referenced by the code. |
| Since we are using the AMBA framework, the name of the clock |
| providing the interconnect should be "apb_pclk", and some |
| coresight blocks also have an additional clock "atclk", which |
| clocks the core of that coresight component. The latter clock |
| is optional. |
| |
| * port or ports: see "Graph bindings for Coresight" below. |
| |
| * Additional required property for Embedded Trace Macrocell (version 3.x and |
| version 4.x): |
| * cpu: the cpu phandle this ETM/PTM is affined to. Do not |
| assume it to default to CPU0 if omitted. |
| |
| * Additional required properties for System Trace Macrocells (STM): |
| * reg: along with the physical base address and length of the register |
| set as described above, another entry is required to describe the |
| mapping of the extended stimulus port area. |
| |
| * reg-names: the only acceptable values are "stm-base" and |
| "stm-stimulus-base", each corresponding to the areas defined in "reg". |
| |
| * Required properties for Coresight Cross Trigger Interface (CTI) |
| See coresight-cti.yaml for full CTI definitions. |
| |
| * Required properties for devices that don't show up on the AMBA bus, such as |
| non-configurable replicators and non-configurable funnels: |
| |
| * compatible: Currently supported value is (note the absence of the |
| AMBA markee): |
| - Coresight Non-configurable Replicator: |
| "arm,coresight-static-replicator"; |
| "arm,coresight-replicator"; (OBSOLETE. For backward |
| compatibility and will be removed) |
| |
| - Coresight Non-configurable Funnel: |
| "arm,coresight-static-funnel"; |
| |
| * port or ports: see "Graph bindings for Coresight" below. |
| |
| * Optional properties for all components: |
| |
| * arm,coresight-loses-context-with-cpu : boolean. Indicates that the |
| hardware will lose register context on CPU power down (e.g. CPUIdle). |
| An example of where this may be needed are systems which contain a |
| coresight component and CPU in the same power domain. When the CPU |
| powers down the coresight component also powers down and loses its |
| context. This property is currently only used for the ETM 4.x driver. |
| |
| * Optional properties for ETM/PTMs: |
| |
| * arm,cp14: must be present if the system accesses ETM/PTM management |
| registers via co-processor 14. |
| |
| * qcom,skip-power-up: boolean. Indicates that an implementation can |
| skip powering up the trace unit. TRCPDCR.PU does not have to be set |
| on Qualcomm Technologies Inc. systems since ETMs are in the same power |
| domain as their CPU cores. This property is required to identify such |
| systems with hardware errata where the CPU watchdog counter is stopped |
| when TRCPDCR.PU is set. |
| |
| * Optional property for TMC: |
| |
| * arm,buffer-size: size of contiguous buffer space for TMC ETR |
| (embedded trace router). This property is obsolete. The buffer size |
| can be configured dynamically via buffer_size property in sysfs. |
| |
| * arm,scatter-gather: boolean. Indicates that the TMC-ETR can safely |
| use the SG mode on this system. |
| |
| * Optional property for CATU : |
| * interrupts : Exactly one SPI may be listed for reporting the address |
| error |
| |
| * Optional property for configurable replicators: |
| |
| * qcom,replicator-loses-context: boolean. Indicates that the replicator |
| will lose register context when AMBA clock is removed which is observed |
| in some replicator designs. |
| |
| Graph bindings for Coresight |
| ------------------------------- |
| |
| Coresight components are interconnected to create a data path for the flow of |
| trace data generated from the "sources" to their collection points "sink". |
| Each coresight component must describe the "input" and "output" connections. |
| The connections must be described via generic DT graph bindings as described |
| by the "bindings/graph.txt", where each "port" along with an "endpoint" |
| component represents a hardware port and the connection. |
| |
| * All output ports must be listed inside a child node named "out-ports" |
| * All input ports must be listed inside a child node named "in-ports". |
| * Port address must match the hardware port number. |
| |
| Example: |
| |
| 1. Sinks |
| etb@20010000 { |
| compatible = "arm,coresight-etb10", "arm,primecell"; |
| reg = <0 0x20010000 0 0x1000>; |
| |
| clocks = <&oscclk6a>; |
| clock-names = "apb_pclk"; |
| in-ports { |
| port { |
| etb_in_port: endpoint@0 { |
| remote-endpoint = <&replicator_out_port0>; |
| }; |
| }; |
| }; |
| }; |
| |
| tpiu@20030000 { |
| compatible = "arm,coresight-tpiu", "arm,primecell"; |
| reg = <0 0x20030000 0 0x1000>; |
| |
| clocks = <&oscclk6a>; |
| clock-names = "apb_pclk"; |
| in-ports { |
| port { |
| tpiu_in_port: endpoint@0 { |
| remote-endpoint = <&replicator_out_port1>; |
| }; |
| }; |
| }; |
| }; |
| |
| etr@20070000 { |
| compatible = "arm,coresight-tmc", "arm,primecell"; |
| reg = <0 0x20070000 0 0x1000>; |
| |
| clocks = <&oscclk6a>; |
| clock-names = "apb_pclk"; |
| in-ports { |
| port { |
| etr_in_port: endpoint { |
| remote-endpoint = <&replicator2_out_port0>; |
| }; |
| }; |
| }; |
| |
| out-ports { |
| port { |
| etr_out_port: endpoint { |
| remote-endpoint = <&catu_in_port>; |
| }; |
| }; |
| }; |
| }; |
| |
| 2. Links |
| replicator { |
| /* non-configurable replicators don't show up on the |
| * AMBA bus. As such no need to add "arm,primecell". |
| */ |
| compatible = "arm,coresight-static-replicator"; |
| |
| out-ports { |
| #address-cells = <1>; |
| #size-cells = <0>; |
| |
| /* replicator output ports */ |
| port@0 { |
| reg = <0>; |
| replicator_out_port0: endpoint { |
| remote-endpoint = <&etb_in_port>; |
| }; |
| }; |
| |
| port@1 { |
| reg = <1>; |
| replicator_out_port1: endpoint { |
| remote-endpoint = <&tpiu_in_port>; |
| }; |
| }; |
| }; |
| |
| in-ports { |
| port { |
| replicator_in_port0: endpoint { |
| remote-endpoint = <&funnel_out_port0>; |
| }; |
| }; |
| }; |
| }; |
| |
| funnel { |
| /* |
| * non-configurable funnel don't show up on the AMBA |
| * bus. As such no need to add "arm,primecell". |
| */ |
| compatible = "arm,coresight-static-funnel"; |
| clocks = <&crg_ctrl HI3660_PCLK>; |
| clock-names = "apb_pclk"; |
| |
| out-ports { |
| port { |
| combo_funnel_out: endpoint { |
| remote-endpoint = <&top_funnel_in>; |
| }; |
| }; |
| }; |
| |
| in-ports { |
| #address-cells = <1>; |
| #size-cells = <0>; |
| |
| port@0 { |
| reg = <0>; |
| combo_funnel_in0: endpoint { |
| remote-endpoint = <&cluster0_etf_out>; |
| }; |
| }; |
| |
| port@1 { |
| reg = <1>; |
| combo_funnel_in1: endpoint { |
| remote-endpoint = <&cluster1_etf_out>; |
| }; |
| }; |
| }; |
| }; |
| |
| funnel@20040000 { |
| compatible = "arm,coresight-dynamic-funnel", "arm,primecell"; |
| reg = <0 0x20040000 0 0x1000>; |
| |
| clocks = <&oscclk6a>; |
| clock-names = "apb_pclk"; |
| out-ports { |
| port { |
| funnel_out_port0: endpoint { |
| remote-endpoint = |
| <&replicator_in_port0>; |
| }; |
| }; |
| }; |
| |
| in-ports { |
| #address-cells = <1>; |
| #size-cells = <0>; |
| |
| port@0 { |
| reg = <0>; |
| funnel_in_port0: endpoint { |
| remote-endpoint = <&ptm0_out_port>; |
| }; |
| }; |
| |
| port@1 { |
| reg = <1>; |
| funnel_in_port1: endpoint { |
| remote-endpoint = <&ptm1_out_port>; |
| }; |
| }; |
| |
| port@2 { |
| reg = <2>; |
| funnel_in_port2: endpoint { |
| remote-endpoint = <&etm0_out_port>; |
| }; |
| }; |
| |
| }; |
| }; |
| |
| 3. Sources |
| ptm@2201c000 { |
| compatible = "arm,coresight-etm3x", "arm,primecell"; |
| reg = <0 0x2201c000 0 0x1000>; |
| |
| cpu = <&cpu0>; |
| clocks = <&oscclk6a>; |
| clock-names = "apb_pclk"; |
| out-ports { |
| port { |
| ptm0_out_port: endpoint { |
| remote-endpoint = <&funnel_in_port0>; |
| }; |
| }; |
| }; |
| }; |
| |
| ptm@2201d000 { |
| compatible = "arm,coresight-etm3x", "arm,primecell"; |
| reg = <0 0x2201d000 0 0x1000>; |
| |
| cpu = <&cpu1>; |
| clocks = <&oscclk6a>; |
| clock-names = "apb_pclk"; |
| out-ports { |
| port { |
| ptm1_out_port: endpoint { |
| remote-endpoint = <&funnel_in_port1>; |
| }; |
| }; |
| }; |
| }; |
| |
| 4. STM |
| stm@20100000 { |
| compatible = "arm,coresight-stm", "arm,primecell"; |
| reg = <0 0x20100000 0 0x1000>, |
| <0 0x28000000 0 0x180000>; |
| reg-names = "stm-base", "stm-stimulus-base"; |
| |
| clocks = <&soc_smc50mhz>; |
| clock-names = "apb_pclk"; |
| out-ports { |
| port { |
| stm_out_port: endpoint { |
| remote-endpoint = <&main_funnel_in_port2>; |
| }; |
| }; |
| }; |
| }; |
| |
| 5. CATU |
| |
| catu@207e0000 { |
| compatible = "arm,coresight-catu", "arm,primecell"; |
| reg = <0 0x207e0000 0 0x1000>; |
| |
| clocks = <&oscclk6a>; |
| clock-names = "apb_pclk"; |
| |
| interrupts = <GIC_SPI 4 IRQ_TYPE_LEVEL_HIGH>; |
| in-ports { |
| port { |
| catu_in_port: endpoint { |
| remote-endpoint = <&etr_out_port>; |
| }; |
| }; |
| }; |
| }; |
| |
| [1]. There is currently two version of STM: STM32 and STM500. Both |
| have the same HW interface and as such don't need an explicit binding name. |