| // SPDX-License-Identifier: GPL-2.0 |
| /* |
| * NVM Express device driver verbose errors |
| * Copyright (c) 2022, Oracle and/or its affiliates |
| */ |
| |
| #include "nvme.h" |
| |
| static const char * const nvme_ops[] = { |
| [nvme_cmd_flush] = "Flush", |
| [nvme_cmd_write] = "Write", |
| [nvme_cmd_read] = "Read", |
| [nvme_cmd_write_uncor] = "Write Uncorrectable", |
| [nvme_cmd_compare] = "Compare", |
| [nvme_cmd_write_zeroes] = "Write Zeros", |
| [nvme_cmd_dsm] = "Dataset Management", |
| [nvme_cmd_verify] = "Verify", |
| [nvme_cmd_resv_register] = "Reservation Register", |
| [nvme_cmd_resv_report] = "Reservation Report", |
| [nvme_cmd_resv_acquire] = "Reservation Acquire", |
| [nvme_cmd_resv_release] = "Reservation Release", |
| [nvme_cmd_zone_mgmt_send] = "Zone Management Send", |
| [nvme_cmd_zone_mgmt_recv] = "Zone Management Receive", |
| [nvme_cmd_zone_append] = "Zone Management Append", |
| }; |
| |
| static const char * const nvme_admin_ops[] = { |
| [nvme_admin_delete_sq] = "Delete SQ", |
| [nvme_admin_create_sq] = "Create SQ", |
| [nvme_admin_get_log_page] = "Get Log Page", |
| [nvme_admin_delete_cq] = "Delete CQ", |
| [nvme_admin_create_cq] = "Create CQ", |
| [nvme_admin_identify] = "Identify", |
| [nvme_admin_abort_cmd] = "Abort Command", |
| [nvme_admin_set_features] = "Set Features", |
| [nvme_admin_get_features] = "Get Features", |
| [nvme_admin_async_event] = "Async Event", |
| [nvme_admin_ns_mgmt] = "Namespace Management", |
| [nvme_admin_activate_fw] = "Activate Firmware", |
| [nvme_admin_download_fw] = "Download Firmware", |
| [nvme_admin_dev_self_test] = "Device Self Test", |
| [nvme_admin_ns_attach] = "Namespace Attach", |
| [nvme_admin_keep_alive] = "Keep Alive", |
| [nvme_admin_directive_send] = "Directive Send", |
| [nvme_admin_directive_recv] = "Directive Receive", |
| [nvme_admin_virtual_mgmt] = "Virtual Management", |
| [nvme_admin_nvme_mi_send] = "NVMe Send MI", |
| [nvme_admin_nvme_mi_recv] = "NVMe Receive MI", |
| [nvme_admin_dbbuf] = "Doorbell Buffer Config", |
| [nvme_admin_format_nvm] = "Format NVM", |
| [nvme_admin_security_send] = "Security Send", |
| [nvme_admin_security_recv] = "Security Receive", |
| [nvme_admin_sanitize_nvm] = "Sanitize NVM", |
| [nvme_admin_get_lba_status] = "Get LBA Status", |
| }; |
| |
| static const char * const nvme_statuses[] = { |
| [NVME_SC_SUCCESS] = "Success", |
| [NVME_SC_INVALID_OPCODE] = "Invalid Command Opcode", |
| [NVME_SC_INVALID_FIELD] = "Invalid Field in Command", |
| [NVME_SC_CMDID_CONFLICT] = "Command ID Conflict", |
| [NVME_SC_DATA_XFER_ERROR] = "Data Transfer Error", |
| [NVME_SC_POWER_LOSS] = "Commands Aborted due to Power Loss Notification", |
| [NVME_SC_INTERNAL] = "Internal Error", |
| [NVME_SC_ABORT_REQ] = "Command Abort Requested", |
| [NVME_SC_ABORT_QUEUE] = "Command Aborted due to SQ Deletion", |
| [NVME_SC_FUSED_FAIL] = "Command Aborted due to Failed Fused Command", |
| [NVME_SC_FUSED_MISSING] = "Command Aborted due to Missing Fused Command", |
| [NVME_SC_INVALID_NS] = "Invalid Namespace or Format", |
| [NVME_SC_CMD_SEQ_ERROR] = "Command Sequence Error", |
| [NVME_SC_SGL_INVALID_LAST] = "Invalid SGL Segment Descriptor", |
| [NVME_SC_SGL_INVALID_COUNT] = "Invalid Number of SGL Descriptors", |
| [NVME_SC_SGL_INVALID_DATA] = "Data SGL Length Invalid", |
| [NVME_SC_SGL_INVALID_METADATA] = "Metadata SGL Length Invalid", |
| [NVME_SC_SGL_INVALID_TYPE] = "SGL Descriptor Type Invalid", |
| [NVME_SC_CMB_INVALID_USE] = "Invalid Use of Controller Memory Buffer", |
| [NVME_SC_PRP_INVALID_OFFSET] = "PRP Offset Invalid", |
| [NVME_SC_ATOMIC_WU_EXCEEDED] = "Atomic Write Unit Exceeded", |
| [NVME_SC_OP_DENIED] = "Operation Denied", |
| [NVME_SC_SGL_INVALID_OFFSET] = "SGL Offset Invalid", |
| [NVME_SC_RESERVED] = "Reserved", |
| [NVME_SC_HOST_ID_INCONSIST] = "Host Identifier Inconsistent Format", |
| [NVME_SC_KA_TIMEOUT_EXPIRED] = "Keep Alive Timeout Expired", |
| [NVME_SC_KA_TIMEOUT_INVALID] = "Keep Alive Timeout Invalid", |
| [NVME_SC_ABORTED_PREEMPT_ABORT] = "Command Aborted due to Preempt and Abort", |
| [NVME_SC_SANITIZE_FAILED] = "Sanitize Failed", |
| [NVME_SC_SANITIZE_IN_PROGRESS] = "Sanitize In Progress", |
| [NVME_SC_SGL_INVALID_GRANULARITY] = "SGL Data Block Granularity Invalid", |
| [NVME_SC_CMD_NOT_SUP_CMB_QUEUE] = "Command Not Supported for Queue in CMB", |
| [NVME_SC_NS_WRITE_PROTECTED] = "Namespace is Write Protected", |
| [NVME_SC_CMD_INTERRUPTED] = "Command Interrupted", |
| [NVME_SC_TRANSIENT_TR_ERR] = "Transient Transport Error", |
| [NVME_SC_ADMIN_COMMAND_MEDIA_NOT_READY] = "Admin Command Media Not Ready", |
| [NVME_SC_INVALID_IO_CMD_SET] = "Invalid IO Command Set", |
| [NVME_SC_LBA_RANGE] = "LBA Out of Range", |
| [NVME_SC_CAP_EXCEEDED] = "Capacity Exceeded", |
| [NVME_SC_NS_NOT_READY] = "Namespace Not Ready", |
| [NVME_SC_RESERVATION_CONFLICT] = "Reservation Conflict", |
| [NVME_SC_FORMAT_IN_PROGRESS] = "Format In Progress", |
| [NVME_SC_CQ_INVALID] = "Completion Queue Invalid", |
| [NVME_SC_QID_INVALID] = "Invalid Queue Identifier", |
| [NVME_SC_QUEUE_SIZE] = "Invalid Queue Size", |
| [NVME_SC_ABORT_LIMIT] = "Abort Command Limit Exceeded", |
| [NVME_SC_ABORT_MISSING] = "Reserved", /* XXX */ |
| [NVME_SC_ASYNC_LIMIT] = "Asynchronous Event Request Limit Exceeded", |
| [NVME_SC_FIRMWARE_SLOT] = "Invalid Firmware Slot", |
| [NVME_SC_FIRMWARE_IMAGE] = "Invalid Firmware Image", |
| [NVME_SC_INVALID_VECTOR] = "Invalid Interrupt Vector", |
| [NVME_SC_INVALID_LOG_PAGE] = "Invalid Log Page", |
| [NVME_SC_INVALID_FORMAT] = "Invalid Format", |
| [NVME_SC_FW_NEEDS_CONV_RESET] = "Firmware Activation Requires Conventional Reset", |
| [NVME_SC_INVALID_QUEUE] = "Invalid Queue Deletion", |
| [NVME_SC_FEATURE_NOT_SAVEABLE] = "Feature Identifier Not Saveable", |
| [NVME_SC_FEATURE_NOT_CHANGEABLE] = "Feature Not Changeable", |
| [NVME_SC_FEATURE_NOT_PER_NS] = "Feature Not Namespace Specific", |
| [NVME_SC_FW_NEEDS_SUBSYS_RESET] = "Firmware Activation Requires NVM Subsystem Reset", |
| [NVME_SC_FW_NEEDS_RESET] = "Firmware Activation Requires Reset", |
| [NVME_SC_FW_NEEDS_MAX_TIME] = "Firmware Activation Requires Maximum Time Violation", |
| [NVME_SC_FW_ACTIVATE_PROHIBITED] = "Firmware Activation Prohibited", |
| [NVME_SC_OVERLAPPING_RANGE] = "Overlapping Range", |
| [NVME_SC_NS_INSUFFICIENT_CAP] = "Namespace Insufficient Capacity", |
| [NVME_SC_NS_ID_UNAVAILABLE] = "Namespace Identifier Unavailable", |
| [NVME_SC_NS_ALREADY_ATTACHED] = "Namespace Already Attached", |
| [NVME_SC_NS_IS_PRIVATE] = "Namespace Is Private", |
| [NVME_SC_NS_NOT_ATTACHED] = "Namespace Not Attached", |
| [NVME_SC_THIN_PROV_NOT_SUPP] = "Thin Provisioning Not Supported", |
| [NVME_SC_CTRL_LIST_INVALID] = "Controller List Invalid", |
| [NVME_SC_SELT_TEST_IN_PROGRESS] = "Device Self-test In Progress", |
| [NVME_SC_BP_WRITE_PROHIBITED] = "Boot Partition Write Prohibited", |
| [NVME_SC_CTRL_ID_INVALID] = "Invalid Controller Identifier", |
| [NVME_SC_SEC_CTRL_STATE_INVALID] = "Invalid Secondary Controller State", |
| [NVME_SC_CTRL_RES_NUM_INVALID] = "Invalid Number of Controller Resources", |
| [NVME_SC_RES_ID_INVALID] = "Invalid Resource Identifier", |
| [NVME_SC_PMR_SAN_PROHIBITED] = "Sanitize Prohibited", |
| [NVME_SC_ANA_GROUP_ID_INVALID] = "ANA Group Identifier Invalid", |
| [NVME_SC_ANA_ATTACH_FAILED] = "ANA Attach Failed", |
| [NVME_SC_BAD_ATTRIBUTES] = "Conflicting Attributes", |
| [NVME_SC_INVALID_PI] = "Invalid Protection Information", |
| [NVME_SC_READ_ONLY] = "Attempted Write to Read Only Range", |
| [NVME_SC_ONCS_NOT_SUPPORTED] = "ONCS Not Supported", |
| [NVME_SC_ZONE_BOUNDARY_ERROR] = "Zoned Boundary Error", |
| [NVME_SC_ZONE_FULL] = "Zone Is Full", |
| [NVME_SC_ZONE_READ_ONLY] = "Zone Is Read Only", |
| [NVME_SC_ZONE_OFFLINE] = "Zone Is Offline", |
| [NVME_SC_ZONE_INVALID_WRITE] = "Zone Invalid Write", |
| [NVME_SC_ZONE_TOO_MANY_ACTIVE] = "Too Many Active Zones", |
| [NVME_SC_ZONE_TOO_MANY_OPEN] = "Too Many Open Zones", |
| [NVME_SC_ZONE_INVALID_TRANSITION] = "Invalid Zone State Transition", |
| [NVME_SC_WRITE_FAULT] = "Write Fault", |
| [NVME_SC_READ_ERROR] = "Unrecovered Read Error", |
| [NVME_SC_GUARD_CHECK] = "End-to-end Guard Check Error", |
| [NVME_SC_APPTAG_CHECK] = "End-to-end Application Tag Check Error", |
| [NVME_SC_REFTAG_CHECK] = "End-to-end Reference Tag Check Error", |
| [NVME_SC_COMPARE_FAILED] = "Compare Failure", |
| [NVME_SC_ACCESS_DENIED] = "Access Denied", |
| [NVME_SC_UNWRITTEN_BLOCK] = "Deallocated or Unwritten Logical Block", |
| [NVME_SC_INTERNAL_PATH_ERROR] = "Internal Pathing Error", |
| [NVME_SC_ANA_PERSISTENT_LOSS] = "Asymmetric Access Persistent Loss", |
| [NVME_SC_ANA_INACCESSIBLE] = "Asymmetric Access Inaccessible", |
| [NVME_SC_ANA_TRANSITION] = "Asymmetric Access Transition", |
| [NVME_SC_CTRL_PATH_ERROR] = "Controller Pathing Error", |
| [NVME_SC_HOST_PATH_ERROR] = "Host Pathing Error", |
| [NVME_SC_HOST_ABORTED_CMD] = "Host Aborted Command", |
| }; |
| |
| const unsigned char *nvme_get_error_status_str(u16 status) |
| { |
| status &= 0x7ff; |
| if (status < ARRAY_SIZE(nvme_statuses) && nvme_statuses[status]) |
| return nvme_statuses[status & 0x7ff]; |
| return "Unknown"; |
| } |
| |
| const unsigned char *nvme_get_opcode_str(u8 opcode) |
| { |
| if (opcode < ARRAY_SIZE(nvme_ops) && nvme_ops[opcode]) |
| return nvme_ops[opcode]; |
| return "Unknown"; |
| } |
| EXPORT_SYMBOL_GPL(nvme_get_opcode_str); |
| |
| const unsigned char *nvme_get_admin_opcode_str(u8 opcode) |
| { |
| if (opcode < ARRAY_SIZE(nvme_admin_ops) && nvme_admin_ops[opcode]) |
| return nvme_admin_ops[opcode]; |
| return "Unknown"; |
| } |