| .. SPDX-License-Identifier: GPL-2.0 |
| |
| ============================= |
| Network Function Representors |
| ============================= |
| |
| This document describes the semantics and usage of representor netdevices, as |
| used to control internal switching on SmartNICs. For the closely-related port |
| representors on physical (multi-port) switches, see |
| :ref:`Documentation/networking/switchdev.rst <switchdev>`. |
| |
| Motivation |
| ---------- |
| |
| Since the mid-2010s, network cards have started offering more complex |
| virtualisation capabilities than the legacy SR-IOV approach (with its simple |
| MAC/VLAN-based switching model) can support. This led to a desire to offload |
| software-defined networks (such as OpenVSwitch) to these NICs to specify the |
| network connectivity of each function. The resulting designs are variously |
| called SmartNICs or DPUs. |
| |
| Network function representors bring the standard Linux networking stack to |
| virtual switches and IOV devices. Just as each physical port of a Linux- |
| controlled switch has a separate netdev, so does each virtual port of a virtual |
| switch. |
| When the system boots, and before any offload is configured, all packets from |
| the virtual functions appear in the networking stack of the PF via the |
| representors. The PF can thus always communicate freely with the virtual |
| functions. |
| The PF can configure standard Linux forwarding between representors, the uplink |
| or any other netdev (routing, bridging, TC classifiers). |
| |
| Thus, a representor is both a control plane object (representing the function in |
| administrative commands) and a data plane object (one end of a virtual pipe). |
| As a virtual link endpoint, the representor can be configured like any other |
| netdevice; in some cases (e.g. link state) the representee will follow the |
| representor's configuration, while in others there are separate APIs to |
| configure the representee. |
| |
| Definitions |
| ----------- |
| |
| This document uses the term "switchdev function" to refer to the PCIe function |
| which has administrative control over the virtual switch on the device. |
| Typically, this will be a PF, but conceivably a NIC could be configured to grant |
| these administrative privileges instead to a VF or SF (subfunction). |
| Depending on NIC design, a multi-port NIC might have a single switchdev function |
| for the whole device or might have a separate virtual switch, and hence |
| switchdev function, for each physical network port. |
| If the NIC supports nested switching, there might be separate switchdev |
| functions for each nested switch, in which case each switchdev function should |
| only create representors for the ports on the (sub-)switch it directly |
| administers. |
| |
| A "representee" is the object that a representor represents. So for example in |
| the case of a VF representor, the representee is the corresponding VF. |
| |
| What does a representor do? |
| --------------------------- |
| |
| A representor has three main roles. |
| |
| 1. It is used to configure the network connection the representee sees, e.g. |
| link up/down, MTU, etc. For instance, bringing the representor |
| administratively UP should cause the representee to see a link up / carrier |
| on event. |
| 2. It provides the slow path for traffic which does not hit any offloaded |
| fast-path rules in the virtual switch. Packets transmitted on the |
| representor netdevice should be delivered to the representee; packets |
| transmitted by the representee which fail to match any switching rule should |
| be received on the representor netdevice. (That is, there is a virtual pipe |
| connecting the representor to the representee, similar in concept to a veth |
| pair.) |
| This allows software switch implementations (such as OpenVSwitch or a Linux |
| bridge) to forward packets between representees and the rest of the network. |
| 3. It acts as a handle by which switching rules (such as TC filters) can refer |
| to the representee, allowing these rules to be offloaded. |
| |
| The combination of 2) and 3) means that the behaviour (apart from performance) |
| should be the same whether a TC filter is offloaded or not. E.g. a TC rule |
| on a VF representor applies in software to packets received on that representor |
| netdevice, while in hardware offload it would apply to packets transmitted by |
| the representee VF. Conversely, a mirred egress redirect to a VF representor |
| corresponds in hardware to delivery directly to the representee VF. |
| |
| What functions should have a representor? |
| ----------------------------------------- |
| |
| Essentially, for each virtual port on the device's internal switch, there |
| should be a representor. |
| Some vendors have chosen to omit representors for the uplink and the physical |
| network port, which can simplify usage (the uplink netdev becomes in effect the |
| physical port's representor) but does not generalise to devices with multiple |
| ports or uplinks. |
| |
| Thus, the following should all have representors: |
| |
| - VFs belonging to the switchdev function. |
| - Other PFs on the local PCIe controller, and any VFs belonging to them. |
| - PFs and VFs on external PCIe controllers on the device (e.g. for any embedded |
| System-on-Chip within the SmartNIC). |
| - PFs and VFs with other personalities, including network block devices (such |
| as a vDPA virtio-blk PF backed by remote/distributed storage), if (and only |
| if) their network access is implemented through a virtual switch port. [#]_ |
| Note that such functions can require a representor despite the representee |
| not having a netdev. |
| - Subfunctions (SFs) belonging to any of the above PFs or VFs, if they have |
| their own port on the switch (as opposed to using their parent PF's port). |
| - Any accelerators or plugins on the device whose interface to the network is |
| through a virtual switch port, even if they do not have a corresponding PCIe |
| PF or VF. |
| |
| This allows the entire switching behaviour of the NIC to be controlled through |
| representor TC rules. |
| |
| It is a common misunderstanding to conflate virtual ports with PCIe virtual |
| functions or their netdevs. While in simple cases there will be a 1:1 |
| correspondence between VF netdevices and VF representors, more advanced device |
| configurations may not follow this. |
| A PCIe function which does not have network access through the internal switch |
| (not even indirectly through the hardware implementation of whatever services |
| the function provides) should *not* have a representor (even if it has a |
| netdev). |
| Such a function has no switch virtual port for the representor to configure or |
| to be the other end of the virtual pipe. |
| The representor represents the virtual port, not the PCIe function nor the 'end |
| user' netdevice. |
| |
| .. [#] The concept here is that a hardware IP stack in the device performs the |
| translation between block DMA requests and network packets, so that only |
| network packets pass through the virtual port onto the switch. The network |
| access that the IP stack "sees" would then be configurable through tc rules; |
| e.g. its traffic might all be wrapped in a specific VLAN or VxLAN. However, |
| any needed configuration of the block device *qua* block device, not being a |
| networking entity, would not be appropriate for the representor and would |
| thus use some other channel such as devlink. |
| Contrast this with the case of a virtio-blk implementation which forwards the |
| DMA requests unchanged to another PF whose driver then initiates and |
| terminates IP traffic in software; in that case the DMA traffic would *not* |
| run over the virtual switch and the virtio-blk PF should thus *not* have a |
| representor. |
| |
| How are representors created? |
| ----------------------------- |
| |
| The driver instance attached to the switchdev function should, for each virtual |
| port on the switch, create a pure-software netdevice which has some form of |
| in-kernel reference to the switchdev function's own netdevice or driver private |
| data (``netdev_priv()``). |
| This may be by enumerating ports at probe time, reacting dynamically to the |
| creation and destruction of ports at run time, or a combination of the two. |
| |
| The operations of the representor netdevice will generally involve acting |
| through the switchdev function. For example, ``ndo_start_xmit()`` might send |
| the packet through a hardware TX queue attached to the switchdev function, with |
| either packet metadata or queue configuration marking it for delivery to the |
| representee. |
| |
| How are representors identified? |
| -------------------------------- |
| |
| The representor netdevice should *not* directly refer to a PCIe device (e.g. |
| through ``net_dev->dev.parent`` / ``SET_NETDEV_DEV()``), either of the |
| representee or of the switchdev function. |
| Instead, it should implement the ``ndo_get_devlink_port()`` netdevice op, which |
| the kernel uses to provide the ``phys_switch_id`` and ``phys_port_name`` sysfs |
| nodes. (Some legacy drivers implement ``ndo_get_port_parent_id()`` and |
| ``ndo_get_phys_port_name()`` directly, but this is deprecated.) See |
| :ref:`Documentation/networking/devlink/devlink-port.rst <devlink_port>` for the |
| details of this API. |
| |
| It is expected that userland will use this information (e.g. through udev rules) |
| to construct an appropriately informative name or alias for the netdevice. For |
| instance if the switchdev function is ``eth4`` then a representor with a |
| ``phys_port_name`` of ``p0pf1vf2`` might be renamed ``eth4pf1vf2rep``. |
| |
| There are as yet no established conventions for naming representors which do not |
| correspond to PCIe functions (e.g. accelerators and plugins). |
| |
| How do representors interact with TC rules? |
| ------------------------------------------- |
| |
| Any TC rule on a representor applies (in software TC) to packets received by |
| that representor netdevice. Thus, if the delivery part of the rule corresponds |
| to another port on the virtual switch, the driver may choose to offload it to |
| hardware, applying it to packets transmitted by the representee. |
| |
| Similarly, since a TC mirred egress action targeting the representor would (in |
| software) send the packet through the representor (and thus indirectly deliver |
| it to the representee), hardware offload should interpret this as delivery to |
| the representee. |
| |
| As a simple example, if ``PORT_DEV`` is the physical port representor and |
| ``REP_DEV`` is a VF representor, the following rules:: |
| |
| tc filter add dev $REP_DEV parent ffff: protocol ipv4 flower \ |
| action mirred egress redirect dev $PORT_DEV |
| tc filter add dev $PORT_DEV parent ffff: protocol ipv4 flower skip_sw \ |
| action mirred egress mirror dev $REP_DEV |
| |
| would mean that all IPv4 packets from the VF are sent out the physical port, and |
| all IPv4 packets received on the physical port are delivered to the VF in |
| addition to ``PORT_DEV``. (Note that without ``skip_sw`` on the second rule, |
| the VF would get two copies, as the packet reception on ``PORT_DEV`` would |
| trigger the TC rule again and mirror the packet to ``REP_DEV``.) |
| |
| On devices without separate port and uplink representors, ``PORT_DEV`` would |
| instead be the switchdev function's own uplink netdevice. |
| |
| Of course the rules can (if supported by the NIC) include packet-modifying |
| actions (e.g. VLAN push/pop), which should be performed by the virtual switch. |
| |
| Tunnel encapsulation and decapsulation are rather more complicated, as they |
| involve a third netdevice (a tunnel netdev operating in metadata mode, such as |
| a VxLAN device created with ``ip link add vxlan0 type vxlan external``) and |
| require an IP address to be bound to the underlay device (e.g. switchdev |
| function uplink netdev or port representor). TC rules such as:: |
| |
| tc filter add dev $REP_DEV parent ffff: flower \ |
| action tunnel_key set id $VNI src_ip $LOCAL_IP dst_ip $REMOTE_IP \ |
| dst_port 4789 \ |
| action mirred egress redirect dev vxlan0 |
| tc filter add dev vxlan0 parent ffff: flower enc_src_ip $REMOTE_IP \ |
| enc_dst_ip $LOCAL_IP enc_key_id $VNI enc_dst_port 4789 \ |
| action tunnel_key unset action mirred egress redirect dev $REP_DEV |
| |
| where ``LOCAL_IP`` is an IP address bound to ``PORT_DEV``, and ``REMOTE_IP`` is |
| another IP address on the same subnet, mean that packets sent by the VF should |
| be VxLAN encapsulated and sent out the physical port (the driver has to deduce |
| this by a route lookup of ``LOCAL_IP`` leading to ``PORT_DEV``, and also |
| perform an ARP/neighbour table lookup to find the MAC addresses to use in the |
| outer Ethernet frame), while UDP packets received on the physical port with UDP |
| port 4789 should be parsed as VxLAN and, if their VSID matches ``$VNI``, |
| decapsulated and forwarded to the VF. |
| |
| If this all seems complicated, just remember the 'golden rule' of TC offload: |
| the hardware should ensure the same final results as if the packets were |
| processed through the slow path, traversed software TC (except ignoring any |
| ``skip_hw`` rules and applying any ``skip_sw`` rules) and were transmitted or |
| received through the representor netdevices. |
| |
| Configuring the representee's MAC |
| --------------------------------- |
| |
| The representee's link state is controlled through the representor. Setting the |
| representor administratively UP or DOWN should cause carrier ON or OFF at the |
| representee. |
| |
| Setting an MTU on the representor should cause that same MTU to be reported to |
| the representee. |
| (On hardware that allows configuring separate and distinct MTU and MRU values, |
| the representor MTU should correspond to the representee's MRU and vice-versa.) |
| |
| Currently there is no way to use the representor to set the station permanent |
| MAC address of the representee; other methods available to do this include: |
| |
| - legacy SR-IOV (``ip link set DEVICE vf NUM mac LLADDR``) |
| - devlink port function (see **devlink-port(8)** and |
| :ref:`Documentation/networking/devlink/devlink-port.rst <devlink_port>`) |