| .. SPDX-License-Identifier: GPL-2.0 |
| |
| ====================================== |
| CoreSight System Configuration Manager |
| ====================================== |
| |
| :Author: Mike Leach <mike.leach@linaro.org> |
| :Date: October 2020 |
| |
| Introduction |
| ============ |
| |
| The CoreSight System Configuration manager is an API that allows the |
| programming of the CoreSight system with pre-defined configurations that |
| can then be easily enabled from sysfs or perf. |
| |
| Many CoreSight components can be programmed in complex ways - especially ETMs. |
| In addition, components can interact across the CoreSight system, often via |
| the cross trigger components such as CTI and CTM. These system settings can |
| be defined and enabled as named configurations. |
| |
| |
| Basic Concepts |
| ============== |
| |
| This section introduces the basic concepts of a CoreSight system configuration. |
| |
| |
| Features |
| -------- |
| |
| A feature is a named set of programming for a CoreSight device. The programming |
| is device dependent, and can be defined in terms of absolute register values, |
| resource usage and parameter values. |
| |
| The feature is defined using a descriptor. This descriptor is used to load onto |
| a matching device, either when the feature is loaded into the system, or when the |
| CoreSight device is registered with the configuration manager. |
| |
| The load process involves interpreting the descriptor into a set of register |
| accesses in the driver - the resource usage and parameter descriptions |
| translated into appropriate register accesses. This interpretation makes it easy |
| and efficient for the feature to be programmed onto the device when required. |
| |
| The feature will not be active on the device until the feature is enabled, and |
| the device itself is enabled. When the device is enabled then enabled features |
| will be programmed into the device hardware. |
| |
| A feature is enabled as part of a configuration being enabled on the system. |
| |
| |
| Parameter Value |
| ~~~~~~~~~~~~~~~ |
| |
| A parameter value is a named value that may be set by the user prior to the |
| feature being enabled that can adjust the behaviour of the operation programmed |
| by the feature. |
| |
| For example, this could be a count value in a programmed operation that repeats |
| at a given rate. When the feature is enabled then the current value of the |
| parameter is used in programming the device. |
| |
| The feature descriptor defines a default value for a parameter, which is used |
| if the user does not supply a new value. |
| |
| Users can update parameter values using the configfs API for the CoreSight |
| system - which is described below. |
| |
| The current value of the parameter is loaded into the device when the feature |
| is enabled on that device. |
| |
| |
| Configurations |
| -------------- |
| |
| A configuration defines a set of features that are to be used in a trace |
| session where the configuration is selected. For any trace session only one |
| configuration may be selected. |
| |
| The features defined may be on any type of device that is registered |
| to support system configuration. A configuration may select features to be |
| enabled on a class of devices - i.e. any ETMv4, or specific devices, e.g. a |
| specific CTI on the system. |
| |
| As with the feature, a descriptor is used to define the configuration. |
| This will define the features that must be enabled as part of the configuration |
| as well as any preset values that can be used to override default parameter |
| values. |
| |
| |
| Preset Values |
| ~~~~~~~~~~~~~ |
| |
| Preset values are easily selectable sets of parameter values for the features |
| that the configuration uses. The number of values in a single preset set, equals |
| the sum of parameter values in the features used by the configuration. |
| |
| e.g. a configuration consists of 3 features, one has 2 parameters, one has |
| a single parameter, and another has no parameters. A single preset set will |
| therefore have 3 values. |
| |
| Presets are optionally defined by the configuration, up to 15 can be defined. |
| If no preset is selected, then the parameter values defined in the feature |
| are used as normal. |
| |
| |
| Operation |
| ~~~~~~~~~ |
| |
| The following steps take place in the operation of a configuration. |
| |
| 1) In this example, the configuration is 'autofdo', which has an |
| associated feature 'strobing' that works on ETMv4 CoreSight Devices. |
| |
| 2) The configuration is enabled. For example 'perf' may select the |
| configuration as part of its command line:: |
| |
| perf record -e cs_etm/autofdo/ myapp |
| |
| which will enable the 'autofdo' configuration. |
| |
| 3) perf starts tracing on the system. As each ETMv4 that perf uses for |
| trace is enabled, the configuration manager will check if the ETMv4 |
| has a feature that relates to the currently active configuration. |
| In this case 'strobing' is enabled & programmed into the ETMv4. |
| |
| 4) When the ETMv4 is disabled, any registers marked as needing to be |
| saved will be read back. |
| |
| 5) At the end of the perf session, the configuration will be disabled. |
| |
| |
| Viewing Configurations and Features |
| =================================== |
| |
| The set of configurations and features that are currently loaded into the |
| system can be viewed using the configfs API. |
| |
| Mount configfs as normal and the 'cs-syscfg' subsystem will appear:: |
| |
| $ ls /config |
| cs-syscfg stp-policy |
| |
| This has two sub-directories:: |
| |
| $ cd cs-syscfg/ |
| $ ls |
| configurations features |
| |
| The system has the configuration 'autofdo' built in. It may be examined as |
| follows:: |
| |
| $ cd configurations/ |
| $ ls |
| autofdo |
| $ cd autofdo/ |
| $ ls |
| description preset1 preset3 preset5 preset7 preset9 |
| feature_refs preset2 preset4 preset6 preset8 |
| $ cat description |
| Setup ETMs with strobing for autofdo |
| $ cat feature_refs |
| strobing |
| |
| Each preset declared has a preset<n> subdirectory declared. The values for |
| the preset can be examined:: |
| |
| $ cat preset1/values |
| strobing.window = 0x1388 strobing.period = 0x2 |
| $ cat preset2/values |
| strobing.window = 0x1388 strobing.period = 0x4 |
| |
| The features referenced by the configuration can be examined in the features |
| directory:: |
| |
| $ cd ../../features/strobing/ |
| $ ls |
| description matches nr_params params |
| $ cat description |
| Generate periodic trace capture windows. |
| parameter 'window': a number of CPU cycles (W) |
| parameter 'period': trace enabled for W cycles every period x W cycles |
| $ cat matches |
| SRC_ETMV4 |
| $ cat nr_params |
| 2 |
| |
| Move to the params directory to examine and adjust parameters:: |
| |
| cd params |
| $ ls |
| period window |
| $ cd period |
| $ ls |
| value |
| $ cat value |
| 0x2710 |
| # echo 15000 > value |
| # cat value |
| 0x3a98 |
| |
| Parameters adjusted in this way are reflected in all device instances that have |
| loaded the feature. |
| |
| |
| Using Configurations in perf |
| ============================ |
| |
| The configurations loaded into the CoreSight configuration management are |
| also declared in the perf 'cs_etm' event infrastructure so that they can |
| be selected when running trace under perf:: |
| |
| $ ls /sys/devices/cs_etm |
| configurations format perf_event_mux_interval_ms sinks type |
| events nr_addr_filters power |
| |
| Key directories here are 'configurations' - which lists the loaded |
| configurations, and 'events' - a generic perf directory which allows |
| selection on the perf command line.:: |
| |
| $ ls configurations/ |
| autofdo |
| $ cat configurations/autofdo |
| 0xa7c3dddd |
| |
| As with the sinks entries, this provides a hash of the configuration name. |
| The entry in the 'events' directory uses perfs built in syntax generator |
| to substitute the syntax for the name when evaluating the command:: |
| |
| $ ls events/ |
| autofdo |
| $ cat events/autofdo |
| configid=0xa7c3dddd |
| |
| The 'autofdo' configuration may be selected on the perf command line:: |
| |
| $ perf record -e cs_etm/autofdo/u --per-thread <application> |
| |
| A preset to override the current parameter values can also be selected:: |
| |
| $ perf record -e cs_etm/autofdo,preset=1/u --per-thread <application> |
| |
| When configurations are selected in this way, then the trace sink used is |
| automatically selected. |