blob: 0beafed502f56a17d4eb6fe24d8674dea5b21558 [file] [log] [blame]
Marvell SEI (System Error Interrupt) Controller
-----------------------------------------------
Marvell SEI (System Error Interrupt) controller is an interrupt
aggregator. It receives interrupts from several sources and aggregates
them to a single interrupt line (an SPI) on the parent interrupt
controller.
This interrupt controller can handle up to 64 SEIs, a set comes from the
AP and is wired while a second set comes from the CPs by the mean of
MSIs.
Required properties:
- compatible: should be one of:
* "marvell,ap806-sei"
- reg: SEI registers location and length.
- interrupts: identifies the parent IRQ that will be triggered.
- #interrupt-cells: number of cells to define an SEI wired interrupt
coming from the AP, should be 1. The cell is the IRQ
number.
- interrupt-controller: identifies the node as an interrupt controller
for AP interrupts.
- msi-controller: identifies the node as an MSI controller for the CPs
interrupts.
Example:
sei: interrupt-controller@3f0200 {
compatible = "marvell,ap806-sei";
reg = <0x3f0200 0x40>;
interrupts = <GIC_SPI 0 IRQ_TYPE_LEVEL_HIGH>;
#interrupt-cells = <1>;
interrupt-controller;
msi-controller;
};