| // SPDX-License-Identifier: GPL-2.0 |
| |
| #include <linux/context_tracking.h> |
| #include <linux/entry-common.h> |
| #include <linux/livepatch.h> |
| #include <linux/audit.h> |
| |
| #define CREATE_TRACE_POINTS |
| #include <trace/events/syscalls.h> |
| |
| /** |
| * enter_from_user_mode - Establish state when coming from user mode |
| * |
| * Syscall/interrupt entry disables interrupts, but user mode is traced as |
| * interrupts enabled. Also with NO_HZ_FULL RCU might be idle. |
| * |
| * 1) Tell lockdep that interrupts are disabled |
| * 2) Invoke context tracking if enabled to reactivate RCU |
| * 3) Trace interrupts off state |
| */ |
| static __always_inline void enter_from_user_mode(struct pt_regs *regs) |
| { |
| arch_check_user_regs(regs); |
| lockdep_hardirqs_off(CALLER_ADDR0); |
| |
| CT_WARN_ON(ct_state() != CONTEXT_USER); |
| user_exit_irqoff(); |
| |
| instrumentation_begin(); |
| trace_hardirqs_off_finish(); |
| instrumentation_end(); |
| } |
| |
| static inline void syscall_enter_audit(struct pt_regs *regs, long syscall) |
| { |
| if (unlikely(audit_context())) { |
| unsigned long args[6]; |
| |
| syscall_get_arguments(current, regs, args); |
| audit_syscall_entry(syscall, args[0], args[1], args[2], args[3]); |
| } |
| } |
| |
| static long syscall_trace_enter(struct pt_regs *regs, long syscall, |
| unsigned long ti_work) |
| { |
| long ret = 0; |
| |
| /* Handle ptrace */ |
| if (ti_work & (_TIF_SYSCALL_TRACE | _TIF_SYSCALL_EMU)) { |
| ret = arch_syscall_enter_tracehook(regs); |
| if (ret || (ti_work & _TIF_SYSCALL_EMU)) |
| return -1L; |
| } |
| |
| /* Do seccomp after ptrace, to catch any tracer changes. */ |
| if (ti_work & _TIF_SECCOMP) { |
| ret = __secure_computing(NULL); |
| if (ret == -1L) |
| return ret; |
| } |
| |
| /* Either of the above might have changed the syscall number */ |
| syscall = syscall_get_nr(current, regs); |
| |
| if (unlikely(ti_work & _TIF_SYSCALL_TRACEPOINT)) |
| trace_sys_enter(regs, syscall); |
| |
| syscall_enter_audit(regs, syscall); |
| |
| return ret ? : syscall; |
| } |
| |
| static __always_inline long |
| __syscall_enter_from_user_work(struct pt_regs *regs, long syscall) |
| { |
| unsigned long ti_work; |
| |
| ti_work = READ_ONCE(current_thread_info()->flags); |
| if (ti_work & SYSCALL_ENTER_WORK) |
| syscall = syscall_trace_enter(regs, syscall, ti_work); |
| |
| return syscall; |
| } |
| |
| long syscall_enter_from_user_mode_work(struct pt_regs *regs, long syscall) |
| { |
| return __syscall_enter_from_user_work(regs, syscall); |
| } |
| |
| noinstr long syscall_enter_from_user_mode(struct pt_regs *regs, long syscall) |
| { |
| long ret; |
| |
| enter_from_user_mode(regs); |
| |
| instrumentation_begin(); |
| local_irq_enable(); |
| ret = __syscall_enter_from_user_work(regs, syscall); |
| instrumentation_end(); |
| |
| return ret; |
| } |
| |
| noinstr void syscall_enter_from_user_mode_prepare(struct pt_regs *regs) |
| { |
| enter_from_user_mode(regs); |
| instrumentation_begin(); |
| local_irq_enable(); |
| instrumentation_end(); |
| } |
| |
| /** |
| * exit_to_user_mode - Fixup state when exiting to user mode |
| * |
| * Syscall/interupt exit enables interrupts, but the kernel state is |
| * interrupts disabled when this is invoked. Also tell RCU about it. |
| * |
| * 1) Trace interrupts on state |
| * 2) Invoke context tracking if enabled to adjust RCU state |
| * 3) Invoke architecture specific last minute exit code, e.g. speculation |
| * mitigations, etc. |
| * 4) Tell lockdep that interrupts are enabled |
| */ |
| static __always_inline void exit_to_user_mode(void) |
| { |
| instrumentation_begin(); |
| trace_hardirqs_on_prepare(); |
| lockdep_hardirqs_on_prepare(CALLER_ADDR0); |
| instrumentation_end(); |
| |
| user_enter_irqoff(); |
| arch_exit_to_user_mode(); |
| lockdep_hardirqs_on(CALLER_ADDR0); |
| } |
| |
| /* Workaround to allow gradual conversion of architecture code */ |
| void __weak arch_do_signal(struct pt_regs *regs) { } |
| |
| static unsigned long exit_to_user_mode_loop(struct pt_regs *regs, |
| unsigned long ti_work) |
| { |
| /* |
| * Before returning to user space ensure that all pending work |
| * items have been completed. |
| */ |
| while (ti_work & EXIT_TO_USER_MODE_WORK) { |
| |
| local_irq_enable_exit_to_user(ti_work); |
| |
| if (ti_work & _TIF_NEED_RESCHED) |
| schedule(); |
| |
| if (ti_work & _TIF_UPROBE) |
| uprobe_notify_resume(regs); |
| |
| if (ti_work & _TIF_PATCH_PENDING) |
| klp_update_patch_state(current); |
| |
| if (ti_work & _TIF_SIGPENDING) |
| arch_do_signal(regs); |
| |
| if (ti_work & _TIF_NOTIFY_RESUME) { |
| clear_thread_flag(TIF_NOTIFY_RESUME); |
| tracehook_notify_resume(regs); |
| rseq_handle_notify_resume(NULL, regs); |
| } |
| |
| /* Architecture specific TIF work */ |
| arch_exit_to_user_mode_work(regs, ti_work); |
| |
| /* |
| * Disable interrupts and reevaluate the work flags as they |
| * might have changed while interrupts and preemption was |
| * enabled above. |
| */ |
| local_irq_disable_exit_to_user(); |
| ti_work = READ_ONCE(current_thread_info()->flags); |
| } |
| |
| /* Return the latest work state for arch_exit_to_user_mode() */ |
| return ti_work; |
| } |
| |
| static void exit_to_user_mode_prepare(struct pt_regs *regs) |
| { |
| unsigned long ti_work = READ_ONCE(current_thread_info()->flags); |
| |
| lockdep_assert_irqs_disabled(); |
| |
| if (unlikely(ti_work & EXIT_TO_USER_MODE_WORK)) |
| ti_work = exit_to_user_mode_loop(regs, ti_work); |
| |
| arch_exit_to_user_mode_prepare(regs, ti_work); |
| |
| /* Ensure that the address limit is intact and no locks are held */ |
| addr_limit_user_check(); |
| lockdep_assert_irqs_disabled(); |
| lockdep_sys_exit(); |
| } |
| |
| #ifndef _TIF_SINGLESTEP |
| static inline bool report_single_step(unsigned long ti_work) |
| { |
| return false; |
| } |
| #else |
| /* |
| * If TIF_SYSCALL_EMU is set, then the only reason to report is when |
| * TIF_SINGLESTEP is set (i.e. PTRACE_SYSEMU_SINGLESTEP). This syscall |
| * instruction has been already reported in syscall_enter_from_user_mode(). |
| */ |
| #define SYSEMU_STEP (_TIF_SINGLESTEP | _TIF_SYSCALL_EMU) |
| |
| static inline bool report_single_step(unsigned long ti_work) |
| { |
| return (ti_work & SYSEMU_STEP) == _TIF_SINGLESTEP; |
| } |
| #endif |
| |
| static void syscall_exit_work(struct pt_regs *regs, unsigned long ti_work) |
| { |
| bool step; |
| |
| audit_syscall_exit(regs); |
| |
| if (ti_work & _TIF_SYSCALL_TRACEPOINT) |
| trace_sys_exit(regs, syscall_get_return_value(current, regs)); |
| |
| step = report_single_step(ti_work); |
| if (step || ti_work & _TIF_SYSCALL_TRACE) |
| arch_syscall_exit_tracehook(regs, step); |
| } |
| |
| /* |
| * Syscall specific exit to user mode preparation. Runs with interrupts |
| * enabled. |
| */ |
| static void syscall_exit_to_user_mode_prepare(struct pt_regs *regs) |
| { |
| u32 cached_flags = READ_ONCE(current_thread_info()->flags); |
| unsigned long nr = syscall_get_nr(current, regs); |
| |
| CT_WARN_ON(ct_state() != CONTEXT_KERNEL); |
| |
| if (IS_ENABLED(CONFIG_PROVE_LOCKING)) { |
| if (WARN(irqs_disabled(), "syscall %lu left IRQs disabled", nr)) |
| local_irq_enable(); |
| } |
| |
| rseq_syscall(regs); |
| |
| /* |
| * Do one-time syscall specific work. If these work items are |
| * enabled, we want to run them exactly once per syscall exit with |
| * interrupts enabled. |
| */ |
| if (unlikely(cached_flags & SYSCALL_EXIT_WORK)) |
| syscall_exit_work(regs, cached_flags); |
| } |
| |
| __visible noinstr void syscall_exit_to_user_mode(struct pt_regs *regs) |
| { |
| instrumentation_begin(); |
| syscall_exit_to_user_mode_prepare(regs); |
| local_irq_disable_exit_to_user(); |
| exit_to_user_mode_prepare(regs); |
| instrumentation_end(); |
| exit_to_user_mode(); |
| } |
| |
| noinstr void irqentry_enter_from_user_mode(struct pt_regs *regs) |
| { |
| enter_from_user_mode(regs); |
| } |
| |
| noinstr void irqentry_exit_to_user_mode(struct pt_regs *regs) |
| { |
| instrumentation_begin(); |
| exit_to_user_mode_prepare(regs); |
| instrumentation_end(); |
| exit_to_user_mode(); |
| } |
| |
| noinstr irqentry_state_t irqentry_enter(struct pt_regs *regs) |
| { |
| irqentry_state_t ret = { |
| .exit_rcu = false, |
| }; |
| |
| if (user_mode(regs)) { |
| irqentry_enter_from_user_mode(regs); |
| return ret; |
| } |
| |
| /* |
| * If this entry hit the idle task invoke rcu_irq_enter() whether |
| * RCU is watching or not. |
| * |
| * Interupts can nest when the first interrupt invokes softirq |
| * processing on return which enables interrupts. |
| * |
| * Scheduler ticks in the idle task can mark quiescent state and |
| * terminate a grace period, if and only if the timer interrupt is |
| * not nested into another interrupt. |
| * |
| * Checking for __rcu_is_watching() here would prevent the nesting |
| * interrupt to invoke rcu_irq_enter(). If that nested interrupt is |
| * the tick then rcu_flavor_sched_clock_irq() would wrongfully |
| * assume that it is the first interupt and eventually claim |
| * quiescient state and end grace periods prematurely. |
| * |
| * Unconditionally invoke rcu_irq_enter() so RCU state stays |
| * consistent. |
| * |
| * TINY_RCU does not support EQS, so let the compiler eliminate |
| * this part when enabled. |
| */ |
| if (!IS_ENABLED(CONFIG_TINY_RCU) && is_idle_task(current)) { |
| /* |
| * If RCU is not watching then the same careful |
| * sequence vs. lockdep and tracing is required |
| * as in irq_enter_from_user_mode(). |
| */ |
| lockdep_hardirqs_off(CALLER_ADDR0); |
| rcu_irq_enter(); |
| instrumentation_begin(); |
| trace_hardirqs_off_finish(); |
| instrumentation_end(); |
| |
| ret.exit_rcu = true; |
| return ret; |
| } |
| |
| /* |
| * If RCU is watching then RCU only wants to check whether it needs |
| * to restart the tick in NOHZ mode. rcu_irq_enter_check_tick() |
| * already contains a warning when RCU is not watching, so no point |
| * in having another one here. |
| */ |
| instrumentation_begin(); |
| rcu_irq_enter_check_tick(); |
| /* Use the combo lockdep/tracing function */ |
| trace_hardirqs_off(); |
| instrumentation_end(); |
| |
| return ret; |
| } |
| |
| void irqentry_exit_cond_resched(void) |
| { |
| if (!preempt_count()) { |
| /* Sanity check RCU and thread stack */ |
| rcu_irq_exit_check_preempt(); |
| if (IS_ENABLED(CONFIG_DEBUG_ENTRY)) |
| WARN_ON_ONCE(!on_thread_stack()); |
| if (need_resched()) |
| preempt_schedule_irq(); |
| } |
| } |
| |
| noinstr void irqentry_exit(struct pt_regs *regs, irqentry_state_t state) |
| { |
| lockdep_assert_irqs_disabled(); |
| |
| /* Check whether this returns to user mode */ |
| if (user_mode(regs)) { |
| irqentry_exit_to_user_mode(regs); |
| } else if (!regs_irqs_disabled(regs)) { |
| /* |
| * If RCU was not watching on entry this needs to be done |
| * carefully and needs the same ordering of lockdep/tracing |
| * and RCU as the return to user mode path. |
| */ |
| if (state.exit_rcu) { |
| instrumentation_begin(); |
| /* Tell the tracer that IRET will enable interrupts */ |
| trace_hardirqs_on_prepare(); |
| lockdep_hardirqs_on_prepare(CALLER_ADDR0); |
| instrumentation_end(); |
| rcu_irq_exit(); |
| lockdep_hardirqs_on(CALLER_ADDR0); |
| return; |
| } |
| |
| instrumentation_begin(); |
| if (IS_ENABLED(CONFIG_PREEMPTION)) |
| irqentry_exit_cond_resched(); |
| /* Covers both tracing and lockdep */ |
| trace_hardirqs_on(); |
| instrumentation_end(); |
| } else { |
| /* |
| * IRQ flags state is correct already. Just tell RCU if it |
| * was not watching on entry. |
| */ |
| if (state.exit_rcu) |
| rcu_irq_exit(); |
| } |
| } |