| * ST-Ericsson UX500 PM Domains |
| |
| UX500 supports multiple PM domains which are used to gate power to one or |
| more peripherals on the SOC. |
| |
| The implementation of PM domains for UX500 are based upon the generic PM domain |
| and use the corresponding DT bindings. |
| |
| ==PM domain providers== |
| |
| Required properties: |
| - compatible: Must be "stericsson,ux500-pm-domains". |
| - #power-domain-cells : Number of cells in a power domain specifier, must be 1. |
| |
| Example: |
| pm_domains: pm_domains0 { |
| compatible = "stericsson,ux500-pm-domains"; |
| #power-domain-cells = <1>; |
| }; |
| |
| ==PM domain consumers== |
| |
| Required properties: |
| - power-domains: A phandle and PM domain specifier. Below are the list of |
| valid specifiers: |
| |
| Index Specifier |
| ----- --------- |
| 0 DOMAIN_VAPE |
| |
| Example: |
| sdi0_per1@80126000 { |
| compatible = "arm,pl18x", "arm,primecell"; |
| power-domains = <&pm_domains DOMAIN_VAPE> |
| }; |