| // SPDX-License-Identifier: GPL-2.0 |
| /* |
| * Siemens SIMATIC IPC driver for Watchdogs |
| * |
| * Copyright (c) Siemens AG, 2020-2021 |
| * |
| * Authors: |
| * Gerd Haeussler <gerd.haeussler.ext@siemens.com> |
| */ |
| |
| #include <linux/device.h> |
| #include <linux/errno.h> |
| #include <linux/init.h> |
| #include <linux/io.h> |
| #include <linux/ioport.h> |
| #include <linux/kernel.h> |
| #include <linux/module.h> |
| #include <linux/pci.h> |
| #include <linux/platform_data/x86/p2sb.h> |
| #include <linux/platform_data/x86/simatic-ipc-base.h> |
| #include <linux/platform_device.h> |
| #include <linux/sizes.h> |
| #include <linux/util_macros.h> |
| #include <linux/watchdog.h> |
| |
| #define WD_ENABLE_IOADR 0x62 |
| #define WD_TRIGGER_IOADR 0x66 |
| #define GPIO_COMMUNITY0_PORT_ID 0xaf |
| #define PAD_CFG_DW0_GPP_A_23 0x4b8 |
| #define SAFE_EN_N_427E 0x01 |
| #define SAFE_EN_N_227E 0x04 |
| #define WD_ENABLED 0x01 |
| #define WD_TRIGGERED 0x80 |
| #define WD_MACROMODE 0x02 |
| |
| #define TIMEOUT_MIN 2 |
| #define TIMEOUT_DEF 64 |
| #define TIMEOUT_MAX 64 |
| |
| #define GP_STATUS_REG_227E 0x404D /* IO PORT for SAFE_EN_N on 227E */ |
| |
| static bool nowayout = WATCHDOG_NOWAYOUT; |
| module_param(nowayout, bool, 0000); |
| MODULE_PARM_DESC(nowayout, "Watchdog cannot be stopped once started (default=" |
| __MODULE_STRING(WATCHDOG_NOWAYOUT) ")"); |
| |
| static struct resource gp_status_reg_227e_res = |
| DEFINE_RES_IO_NAMED(GP_STATUS_REG_227E, SZ_1, KBUILD_MODNAME); |
| |
| static struct resource io_resource_enable = |
| DEFINE_RES_IO_NAMED(WD_ENABLE_IOADR, SZ_1, |
| KBUILD_MODNAME " WD_ENABLE_IOADR"); |
| |
| static struct resource io_resource_trigger = |
| DEFINE_RES_IO_NAMED(WD_TRIGGER_IOADR, SZ_1, |
| KBUILD_MODNAME " WD_TRIGGER_IOADR"); |
| |
| /* the actual start will be discovered with p2sb, 0 is a placeholder */ |
| static struct resource mem_resource = |
| DEFINE_RES_MEM_NAMED(0, 0, "WD_RESET_BASE_ADR"); |
| |
| static u32 wd_timeout_table[] = {2, 4, 6, 8, 16, 32, 48, 64 }; |
| static void __iomem *wd_reset_base_addr; |
| |
| static int wd_start(struct watchdog_device *wdd) |
| { |
| outb(inb(WD_ENABLE_IOADR) | WD_ENABLED, WD_ENABLE_IOADR); |
| return 0; |
| } |
| |
| static int wd_stop(struct watchdog_device *wdd) |
| { |
| outb(inb(WD_ENABLE_IOADR) & ~WD_ENABLED, WD_ENABLE_IOADR); |
| return 0; |
| } |
| |
| static int wd_ping(struct watchdog_device *wdd) |
| { |
| inb(WD_TRIGGER_IOADR); |
| return 0; |
| } |
| |
| static int wd_set_timeout(struct watchdog_device *wdd, unsigned int t) |
| { |
| int timeout_idx = find_closest(t, wd_timeout_table, |
| ARRAY_SIZE(wd_timeout_table)); |
| |
| outb((inb(WD_ENABLE_IOADR) & 0xc7) | timeout_idx << 3, WD_ENABLE_IOADR); |
| wdd->timeout = wd_timeout_table[timeout_idx]; |
| return 0; |
| } |
| |
| static const struct watchdog_info wdt_ident = { |
| .options = WDIOF_MAGICCLOSE | WDIOF_KEEPALIVEPING | |
| WDIOF_SETTIMEOUT, |
| .identity = KBUILD_MODNAME, |
| }; |
| |
| static const struct watchdog_ops wdt_ops = { |
| .owner = THIS_MODULE, |
| .start = wd_start, |
| .stop = wd_stop, |
| .ping = wd_ping, |
| .set_timeout = wd_set_timeout, |
| }; |
| |
| static void wd_secondary_enable(u32 wdtmode) |
| { |
| u16 resetbit; |
| |
| /* set safe_en_n so we are not just WDIOF_ALARMONLY */ |
| if (wdtmode == SIMATIC_IPC_DEVICE_227E) { |
| /* enable SAFE_EN_N on GP_STATUS_REG_227E */ |
| resetbit = inb(GP_STATUS_REG_227E); |
| outb(resetbit & ~SAFE_EN_N_227E, GP_STATUS_REG_227E); |
| } else { |
| /* enable SAFE_EN_N on PCH D1600 */ |
| resetbit = ioread16(wd_reset_base_addr); |
| iowrite16(resetbit & ~SAFE_EN_N_427E, wd_reset_base_addr); |
| } |
| } |
| |
| static int wd_setup(u32 wdtmode) |
| { |
| unsigned int bootstatus = 0; |
| int timeout_idx; |
| |
| timeout_idx = find_closest(TIMEOUT_DEF, wd_timeout_table, |
| ARRAY_SIZE(wd_timeout_table)); |
| |
| if (inb(WD_ENABLE_IOADR) & WD_TRIGGERED) |
| bootstatus |= WDIOF_CARDRESET; |
| |
| /* reset alarm bit, set macro mode, and set timeout */ |
| outb(WD_TRIGGERED | WD_MACROMODE | timeout_idx << 3, WD_ENABLE_IOADR); |
| |
| wd_secondary_enable(wdtmode); |
| |
| return bootstatus; |
| } |
| |
| static struct watchdog_device wdd_data = { |
| .info = &wdt_ident, |
| .ops = &wdt_ops, |
| .min_timeout = TIMEOUT_MIN, |
| .max_timeout = TIMEOUT_MAX |
| }; |
| |
| static int simatic_ipc_wdt_probe(struct platform_device *pdev) |
| { |
| struct simatic_ipc_platform *plat = pdev->dev.platform_data; |
| struct device *dev = &pdev->dev; |
| struct resource *res; |
| int ret; |
| |
| switch (plat->devmode) { |
| case SIMATIC_IPC_DEVICE_227E: |
| res = &gp_status_reg_227e_res; |
| if (!request_muxed_region(res->start, resource_size(res), res->name)) { |
| dev_err(dev, |
| "Unable to register IO resource at %pR\n", |
| &gp_status_reg_227e_res); |
| return -EBUSY; |
| } |
| fallthrough; |
| case SIMATIC_IPC_DEVICE_427E: |
| wdd_data.parent = dev; |
| break; |
| default: |
| return -EINVAL; |
| } |
| |
| if (!devm_request_region(dev, io_resource_enable.start, |
| resource_size(&io_resource_enable), |
| io_resource_enable.name)) { |
| dev_err(dev, |
| "Unable to register IO resource at %#x\n", |
| WD_ENABLE_IOADR); |
| return -EBUSY; |
| } |
| |
| if (!devm_request_region(dev, io_resource_trigger.start, |
| resource_size(&io_resource_trigger), |
| io_resource_trigger.name)) { |
| dev_err(dev, |
| "Unable to register IO resource at %#x\n", |
| WD_TRIGGER_IOADR); |
| return -EBUSY; |
| } |
| |
| if (plat->devmode == SIMATIC_IPC_DEVICE_427E) { |
| res = &mem_resource; |
| |
| ret = p2sb_bar(NULL, 0, res); |
| if (ret) |
| return ret; |
| |
| /* do the final address calculation */ |
| res->start = res->start + (GPIO_COMMUNITY0_PORT_ID << 16) + |
| PAD_CFG_DW0_GPP_A_23; |
| res->end = res->start + SZ_4 - 1; |
| |
| wd_reset_base_addr = devm_ioremap_resource(dev, res); |
| if (IS_ERR(wd_reset_base_addr)) |
| return PTR_ERR(wd_reset_base_addr); |
| } |
| |
| wdd_data.bootstatus = wd_setup(plat->devmode); |
| if (wdd_data.bootstatus) |
| dev_warn(dev, "last reboot caused by watchdog reset\n"); |
| |
| if (plat->devmode == SIMATIC_IPC_DEVICE_227E) |
| release_region(gp_status_reg_227e_res.start, |
| resource_size(&gp_status_reg_227e_res)); |
| |
| watchdog_set_nowayout(&wdd_data, nowayout); |
| watchdog_stop_on_reboot(&wdd_data); |
| return devm_watchdog_register_device(dev, &wdd_data); |
| } |
| |
| static struct platform_driver simatic_ipc_wdt_driver = { |
| .probe = simatic_ipc_wdt_probe, |
| .driver = { |
| .name = KBUILD_MODNAME, |
| }, |
| }; |
| |
| module_platform_driver(simatic_ipc_wdt_driver); |
| |
| MODULE_LICENSE("GPL v2"); |
| MODULE_ALIAS("platform:" KBUILD_MODNAME); |
| MODULE_AUTHOR("Gerd Haeussler <gerd.haeussler.ext@siemens.com>"); |