| // SPDX-License-Identifier: GPL-2.0+ |
| /* |
| * Hardware monitoring driver for Vicor PLI1209BC Digital Supervisor |
| * |
| * Copyright (c) 2022 9elements GmbH |
| */ |
| |
| #include <linux/delay.h> |
| #include <linux/i2c.h> |
| #include <linux/module.h> |
| #include <linux/pmbus.h> |
| #include <linux/regulator/driver.h> |
| #include "pmbus.h" |
| |
| /* |
| * The capability command is only supported at page 0. Probing the device while |
| * the page register is set to 1 will falsely enable PEC support. Disable |
| * capability probing accordingly, since the PLI1209BC does not have any |
| * additional capabilities. |
| */ |
| static struct pmbus_platform_data pli1209bc_plat_data = { |
| .flags = PMBUS_NO_CAPABILITY, |
| }; |
| |
| static int pli1209bc_read_word_data(struct i2c_client *client, int page, |
| int phase, int reg) |
| { |
| int data; |
| |
| switch (reg) { |
| /* PMBUS_READ_POUT uses a direct format with R=0 */ |
| case PMBUS_READ_POUT: |
| data = pmbus_read_word_data(client, page, phase, reg); |
| if (data < 0) |
| return data; |
| data = sign_extend32(data, 15) * 10; |
| return clamp_val(data, -32768, 32767) & 0xffff; |
| /* |
| * PMBUS_READ_VOUT and PMBUS_READ_TEMPERATURE_1 return invalid data |
| * when the BCM is turned off. Since it is not possible to return |
| * ENODATA error, return zero instead. |
| */ |
| case PMBUS_READ_VOUT: |
| case PMBUS_READ_TEMPERATURE_1: |
| data = pmbus_read_word_data(client, page, phase, |
| PMBUS_STATUS_WORD); |
| if (data < 0) |
| return data; |
| if (data & PB_STATUS_POWER_GOOD_N) |
| return 0; |
| return pmbus_read_word_data(client, page, phase, reg); |
| default: |
| return -ENODATA; |
| } |
| } |
| |
| static int pli1209bc_write_byte(struct i2c_client *client, int page, u8 reg) |
| { |
| int ret; |
| |
| switch (reg) { |
| case PMBUS_CLEAR_FAULTS: |
| ret = pmbus_write_byte(client, page, reg); |
| /* |
| * PLI1209 takes 230 usec to execute the CLEAR_FAULTS command. |
| * During that time it's busy and NACKs all requests on the |
| * SMBUS interface. It also NACKs reads on PMBUS_STATUS_BYTE |
| * making it impossible to poll the BUSY flag. |
| * |
| * Just wait for not BUSY unconditionally. |
| */ |
| usleep_range(250, 300); |
| break; |
| default: |
| ret = -ENODATA; |
| break; |
| } |
| return ret; |
| } |
| |
| #if IS_ENABLED(CONFIG_SENSORS_PLI1209BC_REGULATOR) |
| static const struct regulator_desc pli1209bc_reg_desc = { |
| .name = "vout2", |
| .id = 1, |
| .of_match = of_match_ptr("vout2"), |
| .regulators_node = of_match_ptr("regulators"), |
| .ops = &pmbus_regulator_ops, |
| .type = REGULATOR_VOLTAGE, |
| .owner = THIS_MODULE, |
| }; |
| #endif |
| |
| static struct pmbus_driver_info pli1209bc_info = { |
| .pages = 2, |
| .format[PSC_VOLTAGE_IN] = direct, |
| .format[PSC_VOLTAGE_OUT] = direct, |
| .format[PSC_CURRENT_IN] = direct, |
| .format[PSC_CURRENT_OUT] = direct, |
| .format[PSC_POWER] = direct, |
| .format[PSC_TEMPERATURE] = direct, |
| .m[PSC_VOLTAGE_IN] = 1, |
| .b[PSC_VOLTAGE_IN] = 0, |
| .R[PSC_VOLTAGE_IN] = 1, |
| .m[PSC_VOLTAGE_OUT] = 1, |
| .b[PSC_VOLTAGE_OUT] = 0, |
| .R[PSC_VOLTAGE_OUT] = 1, |
| .m[PSC_CURRENT_IN] = 1, |
| .b[PSC_CURRENT_IN] = 0, |
| .R[PSC_CURRENT_IN] = 3, |
| .m[PSC_CURRENT_OUT] = 1, |
| .b[PSC_CURRENT_OUT] = 0, |
| .R[PSC_CURRENT_OUT] = 2, |
| .m[PSC_POWER] = 1, |
| .b[PSC_POWER] = 0, |
| .R[PSC_POWER] = 1, |
| .m[PSC_TEMPERATURE] = 1, |
| .b[PSC_TEMPERATURE] = 0, |
| .R[PSC_TEMPERATURE] = 0, |
| /* |
| * Page 0 sums up all attributes except voltage readings. |
| * The pli1209 digital supervisor only contains a single BCM, making |
| * page 0 redundant. |
| */ |
| .func[1] = PMBUS_HAVE_VIN | PMBUS_HAVE_VOUT |
| | PMBUS_HAVE_IIN | PMBUS_HAVE_IOUT |
| | PMBUS_HAVE_PIN | PMBUS_HAVE_POUT |
| | PMBUS_HAVE_TEMP | PMBUS_HAVE_STATUS_TEMP |
| | PMBUS_HAVE_STATUS_IOUT | PMBUS_HAVE_STATUS_INPUT, |
| .read_word_data = pli1209bc_read_word_data, |
| .write_byte = pli1209bc_write_byte, |
| #if IS_ENABLED(CONFIG_SENSORS_PLI1209BC_REGULATOR) |
| .num_regulators = 1, |
| .reg_desc = &pli1209bc_reg_desc, |
| #endif |
| }; |
| |
| static int pli1209bc_probe(struct i2c_client *client) |
| { |
| client->dev.platform_data = &pli1209bc_plat_data; |
| return pmbus_do_probe(client, &pli1209bc_info); |
| } |
| |
| static const struct i2c_device_id pli1209bc_id[] = { |
| {"pli1209bc", 0}, |
| {} |
| }; |
| |
| MODULE_DEVICE_TABLE(i2c, pli1209bc_id); |
| |
| #ifdef CONFIG_OF |
| static const struct of_device_id pli1209bc_of_match[] = { |
| { .compatible = "vicor,pli1209bc" }, |
| { }, |
| }; |
| MODULE_DEVICE_TABLE(of, pli1209bc_of_match); |
| #endif |
| |
| static struct i2c_driver pli1209bc_driver = { |
| .driver = { |
| .name = "pli1209bc", |
| .of_match_table = of_match_ptr(pli1209bc_of_match), |
| }, |
| .probe = pli1209bc_probe, |
| .id_table = pli1209bc_id, |
| }; |
| |
| module_i2c_driver(pli1209bc_driver); |
| |
| MODULE_AUTHOR("Marcello Sylvester Bauer <sylv@sylv.io>"); |
| MODULE_DESCRIPTION("PMBus driver for Vicor PLI1209BC"); |
| MODULE_LICENSE("GPL"); |
| MODULE_IMPORT_NS(PMBUS); |