| // SPDX-License-Identifier: GPL-2.0-only |
| /* |
| * HID Sensors Driver |
| * Copyright (c) 2017, Intel Corporation. |
| */ |
| #include <linux/device.h> |
| #include <linux/hid-sensor-hub.h> |
| #include <linux/iio/buffer.h> |
| #include <linux/iio/iio.h> |
| #include <linux/module.h> |
| #include <linux/platform_device.h> |
| |
| #include "hid-sensor-trigger.h" |
| |
| struct hid_humidity_state { |
| struct hid_sensor_common common_attributes; |
| struct hid_sensor_hub_attribute_info humidity_attr; |
| s32 humidity_data; |
| int scale_pre_decml; |
| int scale_post_decml; |
| int scale_precision; |
| int value_offset; |
| }; |
| |
| /* Channel definitions */ |
| static const struct iio_chan_spec humidity_channels[] = { |
| { |
| .type = IIO_HUMIDITYRELATIVE, |
| .info_mask_separate = BIT(IIO_CHAN_INFO_RAW), |
| .info_mask_shared_by_type = BIT(IIO_CHAN_INFO_OFFSET) | |
| BIT(IIO_CHAN_INFO_SCALE) | |
| BIT(IIO_CHAN_INFO_SAMP_FREQ) | |
| BIT(IIO_CHAN_INFO_HYSTERESIS), |
| }, |
| IIO_CHAN_SOFT_TIMESTAMP(1) |
| }; |
| |
| /* Adjust channel real bits based on report descriptor */ |
| static void humidity_adjust_channel_bit_mask(struct iio_chan_spec *channels, |
| int channel, int size) |
| { |
| channels[channel].scan_type.sign = 's'; |
| /* Real storage bits will change based on the report desc. */ |
| channels[channel].scan_type.realbits = size * 8; |
| /* Maximum size of a sample to capture is s32 */ |
| channels[channel].scan_type.storagebits = sizeof(s32) * 8; |
| } |
| |
| static int humidity_read_raw(struct iio_dev *indio_dev, |
| struct iio_chan_spec const *chan, |
| int *val, int *val2, long mask) |
| { |
| struct hid_humidity_state *humid_st = iio_priv(indio_dev); |
| |
| switch (mask) { |
| case IIO_CHAN_INFO_RAW: |
| if (chan->type != IIO_HUMIDITYRELATIVE) |
| return -EINVAL; |
| hid_sensor_power_state(&humid_st->common_attributes, true); |
| *val = sensor_hub_input_attr_get_raw_value( |
| humid_st->common_attributes.hsdev, |
| HID_USAGE_SENSOR_HUMIDITY, |
| HID_USAGE_SENSOR_ATMOSPHERIC_HUMIDITY, |
| humid_st->humidity_attr.report_id, |
| SENSOR_HUB_SYNC, |
| humid_st->humidity_attr.logical_minimum < 0); |
| hid_sensor_power_state(&humid_st->common_attributes, false); |
| |
| return IIO_VAL_INT; |
| |
| case IIO_CHAN_INFO_SCALE: |
| *val = humid_st->scale_pre_decml; |
| *val2 = humid_st->scale_post_decml; |
| |
| return humid_st->scale_precision; |
| |
| case IIO_CHAN_INFO_OFFSET: |
| *val = humid_st->value_offset; |
| |
| return IIO_VAL_INT; |
| |
| case IIO_CHAN_INFO_SAMP_FREQ: |
| return hid_sensor_read_samp_freq_value( |
| &humid_st->common_attributes, val, val2); |
| |
| case IIO_CHAN_INFO_HYSTERESIS: |
| return hid_sensor_read_raw_hyst_value( |
| &humid_st->common_attributes, val, val2); |
| |
| default: |
| return -EINVAL; |
| } |
| } |
| |
| static int humidity_write_raw(struct iio_dev *indio_dev, |
| struct iio_chan_spec const *chan, |
| int val, int val2, long mask) |
| { |
| struct hid_humidity_state *humid_st = iio_priv(indio_dev); |
| |
| switch (mask) { |
| case IIO_CHAN_INFO_SAMP_FREQ: |
| return hid_sensor_write_samp_freq_value( |
| &humid_st->common_attributes, val, val2); |
| |
| case IIO_CHAN_INFO_HYSTERESIS: |
| return hid_sensor_write_raw_hyst_value( |
| &humid_st->common_attributes, val, val2); |
| |
| default: |
| return -EINVAL; |
| } |
| } |
| |
| static const struct iio_info humidity_info = { |
| .read_raw = &humidity_read_raw, |
| .write_raw = &humidity_write_raw, |
| }; |
| |
| /* Callback handler to send event after all samples are received and captured */ |
| static int humidity_proc_event(struct hid_sensor_hub_device *hsdev, |
| unsigned int usage_id, void *pdev) |
| { |
| struct iio_dev *indio_dev = platform_get_drvdata(pdev); |
| struct hid_humidity_state *humid_st = iio_priv(indio_dev); |
| |
| if (atomic_read(&humid_st->common_attributes.data_ready)) |
| iio_push_to_buffers_with_timestamp(indio_dev, |
| &humid_st->humidity_data, |
| iio_get_time_ns(indio_dev)); |
| |
| return 0; |
| } |
| |
| /* Capture samples in local storage */ |
| static int humidity_capture_sample(struct hid_sensor_hub_device *hsdev, |
| unsigned int usage_id, size_t raw_len, |
| char *raw_data, void *pdev) |
| { |
| struct iio_dev *indio_dev = platform_get_drvdata(pdev); |
| struct hid_humidity_state *humid_st = iio_priv(indio_dev); |
| |
| switch (usage_id) { |
| case HID_USAGE_SENSOR_ATMOSPHERIC_HUMIDITY: |
| humid_st->humidity_data = *(s32 *)raw_data; |
| |
| return 0; |
| default: |
| return -EINVAL; |
| } |
| } |
| |
| /* Parse report which is specific to an usage id */ |
| static int humidity_parse_report(struct platform_device *pdev, |
| struct hid_sensor_hub_device *hsdev, |
| struct iio_chan_spec *channels, |
| unsigned int usage_id, |
| struct hid_humidity_state *st) |
| { |
| int ret; |
| |
| ret = sensor_hub_input_get_attribute_info(hsdev, HID_INPUT_REPORT, |
| usage_id, |
| HID_USAGE_SENSOR_ATMOSPHERIC_HUMIDITY, |
| &st->humidity_attr); |
| if (ret < 0) |
| return ret; |
| |
| humidity_adjust_channel_bit_mask(channels, 0, st->humidity_attr.size); |
| |
| st->scale_precision = hid_sensor_format_scale( |
| HID_USAGE_SENSOR_HUMIDITY, |
| &st->humidity_attr, |
| &st->scale_pre_decml, |
| &st->scale_post_decml); |
| |
| /* Set Sensitivity field ids, when there is no individual modifier */ |
| if (st->common_attributes.sensitivity.index < 0) |
| sensor_hub_input_get_attribute_info(hsdev, |
| HID_FEATURE_REPORT, usage_id, |
| HID_USAGE_SENSOR_DATA_MOD_CHANGE_SENSITIVITY_ABS | |
| HID_USAGE_SENSOR_ATMOSPHERIC_HUMIDITY, |
| &st->common_attributes.sensitivity); |
| |
| return ret; |
| } |
| |
| static struct hid_sensor_hub_callbacks humidity_callbacks = { |
| .send_event = &humidity_proc_event, |
| .capture_sample = &humidity_capture_sample, |
| }; |
| |
| /* Function to initialize the processing for usage id */ |
| static int hid_humidity_probe(struct platform_device *pdev) |
| { |
| static const char *name = "humidity"; |
| struct iio_dev *indio_dev; |
| struct hid_humidity_state *humid_st; |
| struct iio_chan_spec *humid_chans; |
| struct hid_sensor_hub_device *hsdev = dev_get_platdata(&pdev->dev); |
| int ret; |
| |
| indio_dev = devm_iio_device_alloc(&pdev->dev, sizeof(*humid_st)); |
| if (!indio_dev) |
| return -ENOMEM; |
| |
| humid_st = iio_priv(indio_dev); |
| humid_st->common_attributes.hsdev = hsdev; |
| humid_st->common_attributes.pdev = pdev; |
| |
| ret = hid_sensor_parse_common_attributes(hsdev, |
| HID_USAGE_SENSOR_HUMIDITY, |
| &humid_st->common_attributes); |
| if (ret) |
| return ret; |
| |
| humid_chans = devm_kmemdup(&indio_dev->dev, humidity_channels, |
| sizeof(humidity_channels), GFP_KERNEL); |
| if (!humid_chans) |
| return -ENOMEM; |
| |
| ret = humidity_parse_report(pdev, hsdev, humid_chans, |
| HID_USAGE_SENSOR_HUMIDITY, humid_st); |
| if (ret) |
| return ret; |
| |
| indio_dev->channels = humid_chans; |
| indio_dev->num_channels = ARRAY_SIZE(humidity_channels); |
| indio_dev->info = &humidity_info; |
| indio_dev->name = name; |
| indio_dev->modes = INDIO_DIRECT_MODE; |
| |
| atomic_set(&humid_st->common_attributes.data_ready, 0); |
| |
| ret = hid_sensor_setup_trigger(indio_dev, name, |
| &humid_st->common_attributes); |
| if (ret) |
| return ret; |
| |
| platform_set_drvdata(pdev, indio_dev); |
| |
| humidity_callbacks.pdev = pdev; |
| ret = sensor_hub_register_callback(hsdev, HID_USAGE_SENSOR_HUMIDITY, |
| &humidity_callbacks); |
| if (ret) |
| goto error_remove_trigger; |
| |
| ret = iio_device_register(indio_dev); |
| if (ret) |
| goto error_remove_callback; |
| |
| return ret; |
| |
| error_remove_callback: |
| sensor_hub_remove_callback(hsdev, HID_USAGE_SENSOR_HUMIDITY); |
| error_remove_trigger: |
| hid_sensor_remove_trigger(indio_dev, &humid_st->common_attributes); |
| return ret; |
| } |
| |
| /* Function to deinitialize the processing for usage id */ |
| static int hid_humidity_remove(struct platform_device *pdev) |
| { |
| struct hid_sensor_hub_device *hsdev = dev_get_platdata(&pdev->dev); |
| struct iio_dev *indio_dev = platform_get_drvdata(pdev); |
| struct hid_humidity_state *humid_st = iio_priv(indio_dev); |
| |
| iio_device_unregister(indio_dev); |
| sensor_hub_remove_callback(hsdev, HID_USAGE_SENSOR_HUMIDITY); |
| hid_sensor_remove_trigger(indio_dev, &humid_st->common_attributes); |
| |
| return 0; |
| } |
| |
| static const struct platform_device_id hid_humidity_ids[] = { |
| { |
| /* Format: HID-SENSOR-usage_id_in_hex_lowercase */ |
| .name = "HID-SENSOR-200032", |
| }, |
| { /* sentinel */ } |
| }; |
| MODULE_DEVICE_TABLE(platform, hid_humidity_ids); |
| |
| static struct platform_driver hid_humidity_platform_driver = { |
| .id_table = hid_humidity_ids, |
| .driver = { |
| .name = KBUILD_MODNAME, |
| .pm = &hid_sensor_pm_ops, |
| }, |
| .probe = hid_humidity_probe, |
| .remove = hid_humidity_remove, |
| }; |
| module_platform_driver(hid_humidity_platform_driver); |
| |
| MODULE_DESCRIPTION("HID Environmental humidity sensor"); |
| MODULE_AUTHOR("Song Hongyan <hongyan.song@intel.com>"); |
| MODULE_LICENSE("GPL v2"); |