| // SPDX-License-Identifier: GPL-2.0-only | |
| /* | |
| * drivers/thermal/clock_cooling.c | |
| * | |
| * Copyright (C) 2014 Eduardo Valentin <edubezval@gmail.com> | |
| * | |
| * Copyright (C) 2013 Texas Instruments Inc. | |
| * Contact: Eduardo Valentin <eduardo.valentin@ti.com> | |
| * | |
| * Highly based on cpu_cooling.c. | |
| * Copyright (C) 2012 Samsung Electronics Co., Ltd(http://www.samsung.com) | |
| * Copyright (C) 2012 Amit Daniel <amit.kachhap@linaro.org> | |
| */ | |
| #include <linux/clk.h> | |
| #include <linux/cpufreq.h> | |
| #include <linux/device.h> | |
| #include <linux/err.h> | |
| #include <linux/idr.h> | |
| #include <linux/mutex.h> | |
| #include <linux/pm_opp.h> | |
| #include <linux/slab.h> | |
| #include <linux/thermal.h> | |
| #include <linux/clock_cooling.h> | |
| /** | |
| * struct clock_cooling_device - data for cooling device with clock | |
| * @id: unique integer value corresponding to each clock_cooling_device | |
| * registered. | |
| * @dev: struct device pointer to the device being used to cool off using | |
| * clock frequencies. | |
| * @cdev: thermal_cooling_device pointer to keep track of the | |
| * registered cooling device. | |
| * @clk_rate_change_nb: reference to notifier block used to receive clock | |
| * rate changes. | |
| * @freq_table: frequency table used to keep track of available frequencies. | |
| * @clock_state: integer value representing the current state of clock | |
| * cooling devices. | |
| * @clock_val: integer value representing the absolute value of the clipped | |
| * frequency. | |
| * @clk: struct clk reference used to enforce clock limits. | |
| * @lock: mutex lock to protect this struct. | |
| * | |
| * This structure is required for keeping information of each | |
| * clock_cooling_device registered. In order to prevent corruption of this a | |
| * mutex @lock is used. | |
| */ | |
| struct clock_cooling_device { | |
| int id; | |
| struct device *dev; | |
| struct thermal_cooling_device *cdev; | |
| struct notifier_block clk_rate_change_nb; | |
| struct cpufreq_frequency_table *freq_table; | |
| unsigned long clock_state; | |
| unsigned long clock_val; | |
| struct clk *clk; | |
| struct mutex lock; /* lock to protect the content of this struct */ | |
| }; | |
| #define to_clock_cooling_device(x) \ | |
| container_of(x, struct clock_cooling_device, clk_rate_change_nb) | |
| static DEFINE_IDA(clock_ida); | |
| /* Below code defines functions to be used for clock as cooling device */ | |
| enum clock_cooling_property { | |
| GET_LEVEL, | |
| GET_FREQ, | |
| GET_MAXL, | |
| }; | |
| /** | |
| * clock_cooling_get_property - fetch a property of interest for a give cpu. | |
| * @ccdev: clock cooling device reference | |
| * @input: query parameter | |
| * @output: query return | |
| * @property: type of query (frequency, level, max level) | |
| * | |
| * This is the common function to | |
| * 1. get maximum clock cooling states | |
| * 2. translate frequency to cooling state | |
| * 3. translate cooling state to frequency | |
| * Note that the code may be not in good shape | |
| * but it is written in this way in order to: | |
| * a) reduce duplicate code as most of the code can be shared. | |
| * b) make sure the logic is consistent when translating between | |
| * cooling states and frequencies. | |
| * | |
| * Return: 0 on success, -EINVAL when invalid parameters are passed. | |
| */ | |
| static int clock_cooling_get_property(struct clock_cooling_device *ccdev, | |
| unsigned long input, | |
| unsigned long *output, | |
| enum clock_cooling_property property) | |
| { | |
| int i; | |
| unsigned long max_level = 0, level = 0; | |
| unsigned int freq = CPUFREQ_ENTRY_INVALID; | |
| int descend = -1; | |
| struct cpufreq_frequency_table *pos, *table = ccdev->freq_table; | |
| if (!output) | |
| return -EINVAL; | |
| if (!table) | |
| return -EINVAL; | |
| cpufreq_for_each_valid_entry(pos, table) { | |
| /* ignore duplicate entry */ | |
| if (freq == pos->frequency) | |
| continue; | |
| /* get the frequency order */ | |
| if (freq != CPUFREQ_ENTRY_INVALID && descend == -1) | |
| descend = freq > pos->frequency; | |
| freq = pos->frequency; | |
| max_level++; | |
| } | |
| /* No valid cpu frequency entry */ | |
| if (max_level == 0) | |
| return -EINVAL; | |
| /* max_level is an index, not a counter */ | |
| max_level--; | |
| /* get max level */ | |
| if (property == GET_MAXL) { | |
| *output = max_level; | |
| return 0; | |
| } | |
| if (property == GET_FREQ) | |
| level = descend ? input : (max_level - input); | |
| i = 0; | |
| cpufreq_for_each_valid_entry(pos, table) { | |
| /* ignore duplicate entry */ | |
| if (freq == pos->frequency) | |
| continue; | |
| /* now we have a valid frequency entry */ | |
| freq = pos->frequency; | |
| if (property == GET_LEVEL && (unsigned int)input == freq) { | |
| /* get level by frequency */ | |
| *output = descend ? i : (max_level - i); | |
| return 0; | |
| } | |
| if (property == GET_FREQ && level == i) { | |
| /* get frequency by level */ | |
| *output = freq; | |
| return 0; | |
| } | |
| i++; | |
| } | |
| return -EINVAL; | |
| } | |
| /** | |
| * clock_cooling_get_level - return the cooling level of given clock cooling. | |
| * @cdev: reference of a thermal cooling device of used as clock cooling device | |
| * @freq: the frequency of interest | |
| * | |
| * This function will match the cooling level corresponding to the | |
| * requested @freq and return it. | |
| * | |
| * Return: The matched cooling level on success or THERMAL_CSTATE_INVALID | |
| * otherwise. | |
| */ | |
| unsigned long clock_cooling_get_level(struct thermal_cooling_device *cdev, | |
| unsigned long freq) | |
| { | |
| struct clock_cooling_device *ccdev = cdev->devdata; | |
| unsigned long val; | |
| if (clock_cooling_get_property(ccdev, (unsigned long)freq, &val, | |
| GET_LEVEL)) | |
| return THERMAL_CSTATE_INVALID; | |
| return val; | |
| } | |
| EXPORT_SYMBOL_GPL(clock_cooling_get_level); | |
| /** | |
| * clock_cooling_get_frequency - get the absolute value of frequency from level. | |
| * @ccdev: clock cooling device reference | |
| * @level: cooling level | |
| * | |
| * This function matches cooling level with frequency. Based on a cooling level | |
| * of frequency, equals cooling state of cpu cooling device, it will return | |
| * the corresponding frequency. | |
| * e.g level=0 --> 1st MAX FREQ, level=1 ---> 2nd MAX FREQ, .... etc | |
| * | |
| * Return: 0 on error, the corresponding frequency otherwise. | |
| */ | |
| static unsigned long | |
| clock_cooling_get_frequency(struct clock_cooling_device *ccdev, | |
| unsigned long level) | |
| { | |
| int ret = 0; | |
| unsigned long freq; | |
| ret = clock_cooling_get_property(ccdev, level, &freq, GET_FREQ); | |
| if (ret) | |
| return 0; | |
| return freq; | |
| } | |
| /** | |
| * clock_cooling_apply - function to apply frequency clipping. | |
| * @ccdev: clock_cooling_device pointer containing frequency clipping data. | |
| * @cooling_state: value of the cooling state. | |
| * | |
| * Function used to make sure the clock layer is aware of current thermal | |
| * limits. The limits are applied by updating the clock rate in case it is | |
| * higher than the corresponding frequency based on the requested cooling_state. | |
| * | |
| * Return: 0 on success, an error code otherwise (-EINVAL in case wrong | |
| * cooling state). | |
| */ | |
| static int clock_cooling_apply(struct clock_cooling_device *ccdev, | |
| unsigned long cooling_state) | |
| { | |
| unsigned long clip_freq, cur_freq; | |
| int ret = 0; | |
| /* Here we write the clipping */ | |
| /* Check if the old cooling action is same as new cooling action */ | |
| if (ccdev->clock_state == cooling_state) | |
| return 0; | |
| clip_freq = clock_cooling_get_frequency(ccdev, cooling_state); | |
| if (!clip_freq) | |
| return -EINVAL; | |
| cur_freq = clk_get_rate(ccdev->clk); | |
| mutex_lock(&ccdev->lock); | |
| ccdev->clock_state = cooling_state; | |
| ccdev->clock_val = clip_freq; | |
| /* enforce clock level */ | |
| if (cur_freq > clip_freq) | |
| ret = clk_set_rate(ccdev->clk, clip_freq); | |
| mutex_unlock(&ccdev->lock); | |
| return ret; | |
| } | |
| /** | |
| * clock_cooling_clock_notifier - notifier callback on clock rate changes. | |
| * @nb: struct notifier_block * with callback info. | |
| * @event: value showing clock event for which this function invoked. | |
| * @data: callback-specific data | |
| * | |
| * Callback to hijack the notification on clock transition. | |
| * Every time there is a clock change, we intercept all pre change events | |
| * and block the transition in case the new rate infringes thermal limits. | |
| * | |
| * Return: NOTIFY_DONE (success) or NOTIFY_BAD (new_rate > thermal limit). | |
| */ | |
| static int clock_cooling_clock_notifier(struct notifier_block *nb, | |
| unsigned long event, void *data) | |
| { | |
| struct clk_notifier_data *ndata = data; | |
| struct clock_cooling_device *ccdev = to_clock_cooling_device(nb); | |
| switch (event) { | |
| case PRE_RATE_CHANGE: | |
| /* | |
| * checks on current state | |
| * TODO: current method is not best we can find as it | |
| * allows possibly voltage transitions, in case DVFS | |
| * layer is also hijacking clock pre notifications. | |
| */ | |
| if (ndata->new_rate > ccdev->clock_val) | |
| return NOTIFY_BAD; | |
| /* fall through */ | |
| case POST_RATE_CHANGE: | |
| case ABORT_RATE_CHANGE: | |
| default: | |
| return NOTIFY_DONE; | |
| } | |
| } | |
| /* clock cooling device thermal callback functions are defined below */ | |
| /** | |
| * clock_cooling_get_max_state - callback function to get the max cooling state. | |
| * @cdev: thermal cooling device pointer. | |
| * @state: fill this variable with the max cooling state. | |
| * | |
| * Callback for the thermal cooling device to return the clock | |
| * max cooling state. | |
| * | |
| * Return: 0 on success, an error code otherwise. | |
| */ | |
| static int clock_cooling_get_max_state(struct thermal_cooling_device *cdev, | |
| unsigned long *state) | |
| { | |
| struct clock_cooling_device *ccdev = cdev->devdata; | |
| unsigned long count = 0; | |
| int ret; | |
| ret = clock_cooling_get_property(ccdev, 0, &count, GET_MAXL); | |
| if (!ret) | |
| *state = count; | |
| return ret; | |
| } | |
| /** | |
| * clock_cooling_get_cur_state - function to get the current cooling state. | |
| * @cdev: thermal cooling device pointer. | |
| * @state: fill this variable with the current cooling state. | |
| * | |
| * Callback for the thermal cooling device to return the clock | |
| * current cooling state. | |
| * | |
| * Return: 0 (success) | |
| */ | |
| static int clock_cooling_get_cur_state(struct thermal_cooling_device *cdev, | |
| unsigned long *state) | |
| { | |
| struct clock_cooling_device *ccdev = cdev->devdata; | |
| *state = ccdev->clock_state; | |
| return 0; | |
| } | |
| /** | |
| * clock_cooling_set_cur_state - function to set the current cooling state. | |
| * @cdev: thermal cooling device pointer. | |
| * @state: set this variable to the current cooling state. | |
| * | |
| * Callback for the thermal cooling device to change the clock cooling | |
| * current cooling state. | |
| * | |
| * Return: 0 on success, an error code otherwise. | |
| */ | |
| static int clock_cooling_set_cur_state(struct thermal_cooling_device *cdev, | |
| unsigned long state) | |
| { | |
| struct clock_cooling_device *clock_device = cdev->devdata; | |
| return clock_cooling_apply(clock_device, state); | |
| } | |
| /* Bind clock callbacks to thermal cooling device ops */ | |
| static struct thermal_cooling_device_ops const clock_cooling_ops = { | |
| .get_max_state = clock_cooling_get_max_state, | |
| .get_cur_state = clock_cooling_get_cur_state, | |
| .set_cur_state = clock_cooling_set_cur_state, | |
| }; | |
| /** | |
| * clock_cooling_register - function to create clock cooling device. | |
| * @dev: struct device pointer to the device used as clock cooling device. | |
| * @clock_name: string containing the clock used as cooling mechanism. | |
| * | |
| * This interface function registers the clock cooling device with the name | |
| * "thermal-clock-%x". The cooling device is based on clock frequencies. | |
| * The struct device is assumed to be capable of DVFS transitions. | |
| * The OPP layer is used to fetch and fill the available frequencies for | |
| * the referred device. The ordered frequency table is used to control | |
| * the clock cooling device cooling states and to limit clock transitions | |
| * based on the cooling state requested by the thermal framework. | |
| * | |
| * Return: a valid struct thermal_cooling_device pointer on success, | |
| * on failure, it returns a corresponding ERR_PTR(). | |
| */ | |
| struct thermal_cooling_device * | |
| clock_cooling_register(struct device *dev, const char *clock_name) | |
| { | |
| struct thermal_cooling_device *cdev; | |
| struct clock_cooling_device *ccdev = NULL; | |
| char dev_name[THERMAL_NAME_LENGTH]; | |
| int ret = 0; | |
| ccdev = devm_kzalloc(dev, sizeof(*ccdev), GFP_KERNEL); | |
| if (!ccdev) | |
| return ERR_PTR(-ENOMEM); | |
| mutex_init(&ccdev->lock); | |
| ccdev->dev = dev; | |
| ccdev->clk = devm_clk_get(dev, clock_name); | |
| if (IS_ERR(ccdev->clk)) | |
| return ERR_CAST(ccdev->clk); | |
| ret = ida_simple_get(&clock_ida, 0, 0, GFP_KERNEL); | |
| if (ret < 0) | |
| return ERR_PTR(ret); | |
| ccdev->id = ret; | |
| snprintf(dev_name, sizeof(dev_name), "thermal-clock-%d", ccdev->id); | |
| cdev = thermal_cooling_device_register(dev_name, ccdev, | |
| &clock_cooling_ops); | |
| if (IS_ERR(cdev)) { | |
| ida_simple_remove(&clock_ida, ccdev->id); | |
| return ERR_PTR(-EINVAL); | |
| } | |
| ccdev->cdev = cdev; | |
| ccdev->clk_rate_change_nb.notifier_call = clock_cooling_clock_notifier; | |
| /* Assuming someone has already filled the opp table for this device */ | |
| ret = dev_pm_opp_init_cpufreq_table(dev, &ccdev->freq_table); | |
| if (ret) { | |
| ida_simple_remove(&clock_ida, ccdev->id); | |
| return ERR_PTR(ret); | |
| } | |
| ccdev->clock_state = 0; | |
| ccdev->clock_val = clock_cooling_get_frequency(ccdev, 0); | |
| clk_notifier_register(ccdev->clk, &ccdev->clk_rate_change_nb); | |
| return cdev; | |
| } | |
| EXPORT_SYMBOL_GPL(clock_cooling_register); | |
| /** | |
| * clock_cooling_unregister - function to remove clock cooling device. | |
| * @cdev: thermal cooling device pointer. | |
| * | |
| * This interface function unregisters the "thermal-clock-%x" cooling device. | |
| */ | |
| void clock_cooling_unregister(struct thermal_cooling_device *cdev) | |
| { | |
| struct clock_cooling_device *ccdev; | |
| if (!cdev) | |
| return; | |
| ccdev = cdev->devdata; | |
| clk_notifier_unregister(ccdev->clk, &ccdev->clk_rate_change_nb); | |
| dev_pm_opp_free_cpufreq_table(ccdev->dev, &ccdev->freq_table); | |
| thermal_cooling_device_unregister(ccdev->cdev); | |
| ida_simple_remove(&clock_ida, ccdev->id); | |
| } | |
| EXPORT_SYMBOL_GPL(clock_cooling_unregister); |