| // SPDX-License-Identifier: GPL-2.0-or-later |
| /* Lantiq cpu temperature sensor driver |
| * |
| * Copyright (C) 2017 Florian Eckert <fe@dev.tdt.de> |
| */ |
| |
| #include <linux/bitops.h> |
| #include <linux/delay.h> |
| #include <linux/hwmon.h> |
| #include <linux/hwmon-sysfs.h> |
| #include <linux/init.h> |
| #include <linux/module.h> |
| #include <linux/of_device.h> |
| |
| #include <lantiq_soc.h> |
| |
| /* gphy1 configuration register contains cpu temperature */ |
| #define CGU_GPHY1_CR 0x0040 |
| #define CGU_TEMP_PD BIT(19) |
| |
| static void ltq_cputemp_enable(void) |
| { |
| ltq_cgu_w32(ltq_cgu_r32(CGU_GPHY1_CR) | CGU_TEMP_PD, CGU_GPHY1_CR); |
| } |
| |
| static void ltq_cputemp_disable(void *data) |
| { |
| ltq_cgu_w32(ltq_cgu_r32(CGU_GPHY1_CR) & ~CGU_TEMP_PD, CGU_GPHY1_CR); |
| } |
| |
| static int ltq_read(struct device *dev, enum hwmon_sensor_types type, |
| u32 attr, int channel, long *temp) |
| { |
| int value; |
| |
| switch (attr) { |
| case hwmon_temp_input: |
| /* get the temperature including one decimal place */ |
| value = (ltq_cgu_r32(CGU_GPHY1_CR) >> 9) & 0x01FF; |
| value = value * 5; |
| /* range -38 to +154 °C, register value zero is -38.0 °C */ |
| value -= 380; |
| /* scale temp to millidegree */ |
| value = value * 100; |
| break; |
| default: |
| return -EOPNOTSUPP; |
| } |
| |
| *temp = value; |
| return 0; |
| } |
| |
| static umode_t ltq_is_visible(const void *_data, enum hwmon_sensor_types type, |
| u32 attr, int channel) |
| { |
| if (type != hwmon_temp) |
| return 0; |
| |
| switch (attr) { |
| case hwmon_temp_input: |
| return 0444; |
| default: |
| return 0; |
| } |
| } |
| |
| static const struct hwmon_channel_info *ltq_info[] = { |
| HWMON_CHANNEL_INFO(chip, |
| HWMON_C_REGISTER_TZ), |
| HWMON_CHANNEL_INFO(temp, |
| HWMON_T_INPUT), |
| NULL |
| }; |
| |
| static const struct hwmon_ops ltq_hwmon_ops = { |
| .is_visible = ltq_is_visible, |
| .read = ltq_read, |
| }; |
| |
| static const struct hwmon_chip_info ltq_chip_info = { |
| .ops = <q_hwmon_ops, |
| .info = ltq_info, |
| }; |
| |
| static int ltq_cputemp_probe(struct platform_device *pdev) |
| { |
| struct device *hwmon_dev; |
| int err = 0; |
| |
| /* available on vr9 v1.2 SoCs only */ |
| if (ltq_soc_type() != SOC_TYPE_VR9_2) |
| return -ENODEV; |
| |
| err = devm_add_action(&pdev->dev, ltq_cputemp_disable, NULL); |
| if (err) |
| return err; |
| |
| ltq_cputemp_enable(); |
| |
| hwmon_dev = devm_hwmon_device_register_with_info(&pdev->dev, |
| "ltq_cputemp", |
| NULL, |
| <q_chip_info, |
| NULL); |
| |
| if (IS_ERR(hwmon_dev)) { |
| dev_err(&pdev->dev, "Failed to register as hwmon device"); |
| return PTR_ERR(hwmon_dev); |
| } |
| |
| return 0; |
| } |
| |
| const struct of_device_id ltq_cputemp_match[] = { |
| { .compatible = "lantiq,cputemp" }, |
| {}, |
| }; |
| MODULE_DEVICE_TABLE(of, ltq_cputemp_match); |
| |
| static struct platform_driver ltq_cputemp_driver = { |
| .probe = ltq_cputemp_probe, |
| .driver = { |
| .name = "ltq-cputemp", |
| .of_match_table = ltq_cputemp_match, |
| }, |
| }; |
| |
| module_platform_driver(ltq_cputemp_driver); |
| |
| MODULE_AUTHOR("Florian Eckert <fe@dev.tdt.de>"); |
| MODULE_DESCRIPTION("Lantiq cpu temperature sensor driver"); |
| MODULE_LICENSE("GPL"); |