| // SPDX-License-Identifier: GPL-2.0 |
| /* Copyright (c) 2019, Vladimir Oltean <olteanv@gmail.com> |
| */ |
| #include "sja1105.h" |
| |
| #define SJA1105_TAS_CLKSRC_DISABLED 0 |
| #define SJA1105_TAS_CLKSRC_STANDALONE 1 |
| #define SJA1105_TAS_CLKSRC_AS6802 2 |
| #define SJA1105_TAS_CLKSRC_PTP 3 |
| #define SJA1105_GATE_MASK GENMASK_ULL(SJA1105_NUM_TC - 1, 0) |
| |
| #define work_to_sja1105_tas(d) \ |
| container_of((d), struct sja1105_tas_data, tas_work) |
| #define tas_to_sja1105(d) \ |
| container_of((d), struct sja1105_private, tas_data) |
| |
| static int sja1105_tas_set_runtime_params(struct sja1105_private *priv) |
| { |
| struct sja1105_tas_data *tas_data = &priv->tas_data; |
| struct sja1105_gating_config *gating_cfg = &tas_data->gating_cfg; |
| struct dsa_switch *ds = priv->ds; |
| s64 earliest_base_time = S64_MAX; |
| s64 latest_base_time = 0; |
| s64 its_cycle_time = 0; |
| s64 max_cycle_time = 0; |
| int port; |
| |
| tas_data->enabled = false; |
| |
| for (port = 0; port < SJA1105_NUM_PORTS; port++) { |
| const struct tc_taprio_qopt_offload *offload; |
| |
| offload = tas_data->offload[port]; |
| if (!offload) |
| continue; |
| |
| tas_data->enabled = true; |
| |
| if (max_cycle_time < offload->cycle_time) |
| max_cycle_time = offload->cycle_time; |
| if (latest_base_time < offload->base_time) |
| latest_base_time = offload->base_time; |
| if (earliest_base_time > offload->base_time) { |
| earliest_base_time = offload->base_time; |
| its_cycle_time = offload->cycle_time; |
| } |
| } |
| |
| if (!list_empty(&gating_cfg->entries)) { |
| tas_data->enabled = true; |
| |
| if (max_cycle_time < gating_cfg->cycle_time) |
| max_cycle_time = gating_cfg->cycle_time; |
| if (latest_base_time < gating_cfg->base_time) |
| latest_base_time = gating_cfg->base_time; |
| if (earliest_base_time > gating_cfg->base_time) { |
| earliest_base_time = gating_cfg->base_time; |
| its_cycle_time = gating_cfg->cycle_time; |
| } |
| } |
| |
| if (!tas_data->enabled) |
| return 0; |
| |
| /* Roll the earliest base time over until it is in a comparable |
| * time base with the latest, then compare their deltas. |
| * We want to enforce that all ports' base times are within |
| * SJA1105_TAS_MAX_DELTA 200ns cycles of one another. |
| */ |
| earliest_base_time = future_base_time(earliest_base_time, |
| its_cycle_time, |
| latest_base_time); |
| while (earliest_base_time > latest_base_time) |
| earliest_base_time -= its_cycle_time; |
| if (latest_base_time - earliest_base_time > |
| sja1105_delta_to_ns(SJA1105_TAS_MAX_DELTA)) { |
| dev_err(ds->dev, |
| "Base times too far apart: min %llu max %llu\n", |
| earliest_base_time, latest_base_time); |
| return -ERANGE; |
| } |
| |
| tas_data->earliest_base_time = earliest_base_time; |
| tas_data->max_cycle_time = max_cycle_time; |
| |
| dev_dbg(ds->dev, "earliest base time %lld ns\n", earliest_base_time); |
| dev_dbg(ds->dev, "latest base time %lld ns\n", latest_base_time); |
| dev_dbg(ds->dev, "longest cycle time %lld ns\n", max_cycle_time); |
| |
| return 0; |
| } |
| |
| /* Lo and behold: the egress scheduler from hell. |
| * |
| * At the hardware level, the Time-Aware Shaper holds a global linear arrray of |
| * all schedule entries for all ports. These are the Gate Control List (GCL) |
| * entries, let's call them "timeslots" for short. This linear array of |
| * timeslots is held in BLK_IDX_SCHEDULE. |
| * |
| * Then there are a maximum of 8 "execution threads" inside the switch, which |
| * iterate cyclically through the "schedule". Each "cycle" has an entry point |
| * and an exit point, both being timeslot indices in the schedule table. The |
| * hardware calls each cycle a "subschedule". |
| * |
| * Subschedule (cycle) i starts when |
| * ptpclkval >= ptpschtm + BLK_IDX_SCHEDULE_ENTRY_POINTS[i].delta. |
| * |
| * The hardware scheduler iterates BLK_IDX_SCHEDULE with a k ranging from |
| * k = BLK_IDX_SCHEDULE_ENTRY_POINTS[i].address to |
| * k = BLK_IDX_SCHEDULE_PARAMS.subscheind[i] |
| * |
| * For each schedule entry (timeslot) k, the engine executes the gate control |
| * list entry for the duration of BLK_IDX_SCHEDULE[k].delta. |
| * |
| * +---------+ |
| * | | BLK_IDX_SCHEDULE_ENTRY_POINTS_PARAMS |
| * +---------+ |
| * | |
| * +-----------------+ |
| * | .actsubsch |
| * BLK_IDX_SCHEDULE_ENTRY_POINTS v |
| * +-------+-------+ |
| * |cycle 0|cycle 1| |
| * +-------+-------+ |
| * | | | | |
| * +----------------+ | | +-------------------------------------+ |
| * | .subschindx | | .subschindx | |
| * | | +---------------+ | |
| * | .address | .address | | |
| * | | | | |
| * | | | | |
| * | BLK_IDX_SCHEDULE v v | |
| * | +-------+-------+-------+-------+-------+------+ | |
| * | |entry 0|entry 1|entry 2|entry 3|entry 4|entry5| | |
| * | +-------+-------+-------+-------+-------+------+ | |
| * | ^ ^ ^ ^ | |
| * | | | | | | |
| * | +-------------------------+ | | | | |
| * | | +-------------------------------+ | | | |
| * | | | +-------------------+ | | |
| * | | | | | | |
| * | +---------------------------------------------------------------+ | |
| * | |subscheind[0]<=subscheind[1]<=subscheind[2]<=...<=subscheind[7]| | |
| * | +---------------------------------------------------------------+ | |
| * | ^ ^ BLK_IDX_SCHEDULE_PARAMS | |
| * | | | | |
| * +--------+ +-------------------------------------------+ |
| * |
| * In the above picture there are two subschedules (cycles): |
| * |
| * - cycle 0: iterates the schedule table from 0 to 2 (and back) |
| * - cycle 1: iterates the schedule table from 3 to 5 (and back) |
| * |
| * All other possible execution threads must be marked as unused by making |
| * their "subschedule end index" (subscheind) equal to the last valid |
| * subschedule's end index (in this case 5). |
| */ |
| int sja1105_init_scheduling(struct sja1105_private *priv) |
| { |
| struct sja1105_schedule_entry_points_entry *schedule_entry_points; |
| struct sja1105_schedule_entry_points_params_entry |
| *schedule_entry_points_params; |
| struct sja1105_schedule_params_entry *schedule_params; |
| struct sja1105_tas_data *tas_data = &priv->tas_data; |
| struct sja1105_gating_config *gating_cfg = &tas_data->gating_cfg; |
| struct sja1105_schedule_entry *schedule; |
| struct sja1105_table *table; |
| int schedule_start_idx; |
| s64 entry_point_delta; |
| int schedule_end_idx; |
| int num_entries = 0; |
| int num_cycles = 0; |
| int cycle = 0; |
| int i, k = 0; |
| int port, rc; |
| |
| rc = sja1105_tas_set_runtime_params(priv); |
| if (rc < 0) |
| return rc; |
| |
| /* Discard previous Schedule Table */ |
| table = &priv->static_config.tables[BLK_IDX_SCHEDULE]; |
| if (table->entry_count) { |
| kfree(table->entries); |
| table->entry_count = 0; |
| } |
| |
| /* Discard previous Schedule Entry Points Parameters Table */ |
| table = &priv->static_config.tables[BLK_IDX_SCHEDULE_ENTRY_POINTS_PARAMS]; |
| if (table->entry_count) { |
| kfree(table->entries); |
| table->entry_count = 0; |
| } |
| |
| /* Discard previous Schedule Parameters Table */ |
| table = &priv->static_config.tables[BLK_IDX_SCHEDULE_PARAMS]; |
| if (table->entry_count) { |
| kfree(table->entries); |
| table->entry_count = 0; |
| } |
| |
| /* Discard previous Schedule Entry Points Table */ |
| table = &priv->static_config.tables[BLK_IDX_SCHEDULE_ENTRY_POINTS]; |
| if (table->entry_count) { |
| kfree(table->entries); |
| table->entry_count = 0; |
| } |
| |
| /* Figure out the dimensioning of the problem */ |
| for (port = 0; port < SJA1105_NUM_PORTS; port++) { |
| if (tas_data->offload[port]) { |
| num_entries += tas_data->offload[port]->num_entries; |
| num_cycles++; |
| } |
| } |
| |
| if (!list_empty(&gating_cfg->entries)) { |
| num_entries += gating_cfg->num_entries; |
| num_cycles++; |
| } |
| |
| /* Nothing to do */ |
| if (!num_cycles) |
| return 0; |
| |
| /* Pre-allocate space in the static config tables */ |
| |
| /* Schedule Table */ |
| table = &priv->static_config.tables[BLK_IDX_SCHEDULE]; |
| table->entries = kcalloc(num_entries, table->ops->unpacked_entry_size, |
| GFP_KERNEL); |
| if (!table->entries) |
| return -ENOMEM; |
| table->entry_count = num_entries; |
| schedule = table->entries; |
| |
| /* Schedule Points Parameters Table */ |
| table = &priv->static_config.tables[BLK_IDX_SCHEDULE_ENTRY_POINTS_PARAMS]; |
| table->entries = kcalloc(SJA1105_MAX_SCHEDULE_ENTRY_POINTS_PARAMS_COUNT, |
| table->ops->unpacked_entry_size, GFP_KERNEL); |
| if (!table->entries) |
| /* Previously allocated memory will be freed automatically in |
| * sja1105_static_config_free. This is true for all early |
| * returns below. |
| */ |
| return -ENOMEM; |
| table->entry_count = SJA1105_MAX_SCHEDULE_ENTRY_POINTS_PARAMS_COUNT; |
| schedule_entry_points_params = table->entries; |
| |
| /* Schedule Parameters Table */ |
| table = &priv->static_config.tables[BLK_IDX_SCHEDULE_PARAMS]; |
| table->entries = kcalloc(SJA1105_MAX_SCHEDULE_PARAMS_COUNT, |
| table->ops->unpacked_entry_size, GFP_KERNEL); |
| if (!table->entries) |
| return -ENOMEM; |
| table->entry_count = SJA1105_MAX_SCHEDULE_PARAMS_COUNT; |
| schedule_params = table->entries; |
| |
| /* Schedule Entry Points Table */ |
| table = &priv->static_config.tables[BLK_IDX_SCHEDULE_ENTRY_POINTS]; |
| table->entries = kcalloc(num_cycles, table->ops->unpacked_entry_size, |
| GFP_KERNEL); |
| if (!table->entries) |
| return -ENOMEM; |
| table->entry_count = num_cycles; |
| schedule_entry_points = table->entries; |
| |
| /* Finally start populating the static config tables */ |
| schedule_entry_points_params->clksrc = SJA1105_TAS_CLKSRC_PTP; |
| schedule_entry_points_params->actsubsch = num_cycles - 1; |
| |
| for (port = 0; port < SJA1105_NUM_PORTS; port++) { |
| const struct tc_taprio_qopt_offload *offload; |
| /* Relative base time */ |
| s64 rbt; |
| |
| offload = tas_data->offload[port]; |
| if (!offload) |
| continue; |
| |
| schedule_start_idx = k; |
| schedule_end_idx = k + offload->num_entries - 1; |
| /* This is the base time expressed as a number of TAS ticks |
| * relative to PTPSCHTM, which we'll (perhaps improperly) call |
| * the operational base time. |
| */ |
| rbt = future_base_time(offload->base_time, |
| offload->cycle_time, |
| tas_data->earliest_base_time); |
| rbt -= tas_data->earliest_base_time; |
| /* UM10944.pdf 4.2.2. Schedule Entry Points table says that |
| * delta cannot be zero, which is shitty. Advance all relative |
| * base times by 1 TAS delta, so that even the earliest base |
| * time becomes 1 in relative terms. Then start the operational |
| * base time (PTPSCHTM) one TAS delta earlier than planned. |
| */ |
| entry_point_delta = ns_to_sja1105_delta(rbt) + 1; |
| |
| schedule_entry_points[cycle].subschindx = cycle; |
| schedule_entry_points[cycle].delta = entry_point_delta; |
| schedule_entry_points[cycle].address = schedule_start_idx; |
| |
| /* The subschedule end indices need to be |
| * monotonically increasing. |
| */ |
| for (i = cycle; i < 8; i++) |
| schedule_params->subscheind[i] = schedule_end_idx; |
| |
| for (i = 0; i < offload->num_entries; i++, k++) { |
| s64 delta_ns = offload->entries[i].interval; |
| |
| schedule[k].delta = ns_to_sja1105_delta(delta_ns); |
| schedule[k].destports = BIT(port); |
| schedule[k].resmedia_en = true; |
| schedule[k].resmedia = SJA1105_GATE_MASK & |
| ~offload->entries[i].gate_mask; |
| } |
| cycle++; |
| } |
| |
| if (!list_empty(&gating_cfg->entries)) { |
| struct sja1105_gate_entry *e; |
| |
| /* Relative base time */ |
| s64 rbt; |
| |
| schedule_start_idx = k; |
| schedule_end_idx = k + gating_cfg->num_entries - 1; |
| rbt = future_base_time(gating_cfg->base_time, |
| gating_cfg->cycle_time, |
| tas_data->earliest_base_time); |
| rbt -= tas_data->earliest_base_time; |
| entry_point_delta = ns_to_sja1105_delta(rbt) + 1; |
| |
| schedule_entry_points[cycle].subschindx = cycle; |
| schedule_entry_points[cycle].delta = entry_point_delta; |
| schedule_entry_points[cycle].address = schedule_start_idx; |
| |
| for (i = cycle; i < 8; i++) |
| schedule_params->subscheind[i] = schedule_end_idx; |
| |
| list_for_each_entry(e, &gating_cfg->entries, list) { |
| schedule[k].delta = ns_to_sja1105_delta(e->interval); |
| schedule[k].destports = e->rule->vl.destports; |
| schedule[k].setvalid = true; |
| schedule[k].txen = true; |
| schedule[k].vlindex = e->rule->vl.sharindx; |
| schedule[k].winstindex = e->rule->vl.sharindx; |
| if (e->gate_state) /* Gate open */ |
| schedule[k].winst = true; |
| else /* Gate closed */ |
| schedule[k].winend = true; |
| k++; |
| } |
| } |
| |
| return 0; |
| } |
| |
| /* Be there 2 port subschedules, each executing an arbitrary number of gate |
| * open/close events cyclically. |
| * None of those gate events must ever occur at the exact same time, otherwise |
| * the switch is known to act in exotically strange ways. |
| * However the hardware doesn't bother performing these integrity checks. |
| * So here we are with the task of validating whether the new @admin offload |
| * has any conflict with the already established TAS configuration in |
| * tas_data->offload. We already know the other ports are in harmony with one |
| * another, otherwise we wouldn't have saved them. |
| * Each gate event executes periodically, with a period of @cycle_time and a |
| * phase given by its cycle's @base_time plus its offset within the cycle |
| * (which in turn is given by the length of the events prior to it). |
| * There are two aspects to possible collisions: |
| * - Collisions within one cycle's (actually the longest cycle's) time frame. |
| * For that, we need to compare the cartesian product of each possible |
| * occurrence of each event within one cycle time. |
| * - Collisions in the future. Events may not collide within one cycle time, |
| * but if two port schedules don't have the same periodicity (aka the cycle |
| * times aren't multiples of one another), they surely will some time in the |
| * future (actually they will collide an infinite amount of times). |
| */ |
| static bool |
| sja1105_tas_check_conflicts(struct sja1105_private *priv, int port, |
| const struct tc_taprio_qopt_offload *admin) |
| { |
| struct sja1105_tas_data *tas_data = &priv->tas_data; |
| const struct tc_taprio_qopt_offload *offload; |
| s64 max_cycle_time, min_cycle_time; |
| s64 delta1, delta2; |
| s64 rbt1, rbt2; |
| s64 stop_time; |
| s64 t1, t2; |
| int i, j; |
| s32 rem; |
| |
| offload = tas_data->offload[port]; |
| if (!offload) |
| return false; |
| |
| /* Check if the two cycle times are multiples of one another. |
| * If they aren't, then they will surely collide. |
| */ |
| max_cycle_time = max(offload->cycle_time, admin->cycle_time); |
| min_cycle_time = min(offload->cycle_time, admin->cycle_time); |
| div_s64_rem(max_cycle_time, min_cycle_time, &rem); |
| if (rem) |
| return true; |
| |
| /* Calculate the "reduced" base time of each of the two cycles |
| * (transposed back as close to 0 as possible) by dividing to |
| * the cycle time. |
| */ |
| div_s64_rem(offload->base_time, offload->cycle_time, &rem); |
| rbt1 = rem; |
| |
| div_s64_rem(admin->base_time, admin->cycle_time, &rem); |
| rbt2 = rem; |
| |
| stop_time = max_cycle_time + max(rbt1, rbt2); |
| |
| /* delta1 is the relative base time of each GCL entry within |
| * the established ports' TAS config. |
| */ |
| for (i = 0, delta1 = 0; |
| i < offload->num_entries; |
| delta1 += offload->entries[i].interval, i++) { |
| /* delta2 is the relative base time of each GCL entry |
| * within the newly added TAS config. |
| */ |
| for (j = 0, delta2 = 0; |
| j < admin->num_entries; |
| delta2 += admin->entries[j].interval, j++) { |
| /* t1 follows all possible occurrences of the |
| * established ports' GCL entry i within the |
| * first cycle time. |
| */ |
| for (t1 = rbt1 + delta1; |
| t1 <= stop_time; |
| t1 += offload->cycle_time) { |
| /* t2 follows all possible occurrences |
| * of the newly added GCL entry j |
| * within the first cycle time. |
| */ |
| for (t2 = rbt2 + delta2; |
| t2 <= stop_time; |
| t2 += admin->cycle_time) { |
| if (t1 == t2) { |
| dev_warn(priv->ds->dev, |
| "GCL entry %d collides with entry %d of port %d\n", |
| j, i, port); |
| return true; |
| } |
| } |
| } |
| } |
| } |
| |
| return false; |
| } |
| |
| /* Check the tc-taprio configuration on @port for conflicts with the tc-gate |
| * global subschedule. If @port is -1, check it against all ports. |
| * To reuse the sja1105_tas_check_conflicts logic without refactoring it, |
| * convert the gating configuration to a dummy tc-taprio offload structure. |
| */ |
| bool sja1105_gating_check_conflicts(struct sja1105_private *priv, int port, |
| struct netlink_ext_ack *extack) |
| { |
| struct sja1105_gating_config *gating_cfg = &priv->tas_data.gating_cfg; |
| size_t num_entries = gating_cfg->num_entries; |
| struct tc_taprio_qopt_offload *dummy; |
| struct sja1105_gate_entry *e; |
| bool conflict; |
| int i = 0; |
| |
| if (list_empty(&gating_cfg->entries)) |
| return false; |
| |
| dummy = kzalloc(struct_size(dummy, entries, num_entries), GFP_KERNEL); |
| if (!dummy) { |
| NL_SET_ERR_MSG_MOD(extack, "Failed to allocate memory"); |
| return true; |
| } |
| |
| dummy->num_entries = num_entries; |
| dummy->base_time = gating_cfg->base_time; |
| dummy->cycle_time = gating_cfg->cycle_time; |
| |
| list_for_each_entry(e, &gating_cfg->entries, list) |
| dummy->entries[i++].interval = e->interval; |
| |
| if (port != -1) { |
| conflict = sja1105_tas_check_conflicts(priv, port, dummy); |
| } else { |
| for (port = 0; port < SJA1105_NUM_PORTS; port++) { |
| conflict = sja1105_tas_check_conflicts(priv, port, |
| dummy); |
| if (conflict) |
| break; |
| } |
| } |
| |
| kfree(dummy); |
| |
| return conflict; |
| } |
| |
| int sja1105_setup_tc_taprio(struct dsa_switch *ds, int port, |
| struct tc_taprio_qopt_offload *admin) |
| { |
| struct sja1105_private *priv = ds->priv; |
| struct sja1105_tas_data *tas_data = &priv->tas_data; |
| int other_port, rc, i; |
| |
| /* Can't change an already configured port (must delete qdisc first). |
| * Can't delete the qdisc from an unconfigured port. |
| */ |
| if (!!tas_data->offload[port] == admin->enable) |
| return -EINVAL; |
| |
| if (!admin->enable) { |
| taprio_offload_free(tas_data->offload[port]); |
| tas_data->offload[port] = NULL; |
| |
| rc = sja1105_init_scheduling(priv); |
| if (rc < 0) |
| return rc; |
| |
| return sja1105_static_config_reload(priv, SJA1105_SCHEDULING); |
| } |
| |
| /* The cycle time extension is the amount of time the last cycle from |
| * the old OPER needs to be extended in order to phase-align with the |
| * base time of the ADMIN when that becomes the new OPER. |
| * But of course our switch needs to be reset to switch-over between |
| * the ADMIN and the OPER configs - so much for a seamless transition. |
| * So don't add insult over injury and just say we don't support cycle |
| * time extension. |
| */ |
| if (admin->cycle_time_extension) |
| return -ENOTSUPP; |
| |
| for (i = 0; i < admin->num_entries; i++) { |
| s64 delta_ns = admin->entries[i].interval; |
| s64 delta_cycles = ns_to_sja1105_delta(delta_ns); |
| bool too_long, too_short; |
| |
| too_long = (delta_cycles >= SJA1105_TAS_MAX_DELTA); |
| too_short = (delta_cycles == 0); |
| if (too_long || too_short) { |
| dev_err(priv->ds->dev, |
| "Interval %llu too %s for GCL entry %d\n", |
| delta_ns, too_long ? "long" : "short", i); |
| return -ERANGE; |
| } |
| } |
| |
| for (other_port = 0; other_port < SJA1105_NUM_PORTS; other_port++) { |
| if (other_port == port) |
| continue; |
| |
| if (sja1105_tas_check_conflicts(priv, other_port, admin)) |
| return -ERANGE; |
| } |
| |
| if (sja1105_gating_check_conflicts(priv, port, NULL)) { |
| dev_err(ds->dev, "Conflict with tc-gate schedule\n"); |
| return -ERANGE; |
| } |
| |
| tas_data->offload[port] = taprio_offload_get(admin); |
| |
| rc = sja1105_init_scheduling(priv); |
| if (rc < 0) |
| return rc; |
| |
| return sja1105_static_config_reload(priv, SJA1105_SCHEDULING); |
| } |
| |
| static int sja1105_tas_check_running(struct sja1105_private *priv) |
| { |
| struct sja1105_tas_data *tas_data = &priv->tas_data; |
| struct dsa_switch *ds = priv->ds; |
| struct sja1105_ptp_cmd cmd = {0}; |
| int rc; |
| |
| rc = sja1105_ptp_commit(ds, &cmd, SPI_READ); |
| if (rc < 0) |
| return rc; |
| |
| if (cmd.ptpstrtsch == 1) |
| /* Schedule successfully started */ |
| tas_data->state = SJA1105_TAS_STATE_RUNNING; |
| else if (cmd.ptpstopsch == 1) |
| /* Schedule is stopped */ |
| tas_data->state = SJA1105_TAS_STATE_DISABLED; |
| else |
| /* Schedule is probably not configured with PTP clock source */ |
| rc = -EINVAL; |
| |
| return rc; |
| } |
| |
| /* Write to PTPCLKCORP */ |
| static int sja1105_tas_adjust_drift(struct sja1105_private *priv, |
| u64 correction) |
| { |
| const struct sja1105_regs *regs = priv->info->regs; |
| u32 ptpclkcorp = ns_to_sja1105_ticks(correction); |
| |
| return sja1105_xfer_u32(priv, SPI_WRITE, regs->ptpclkcorp, |
| &ptpclkcorp, NULL); |
| } |
| |
| /* Write to PTPSCHTM */ |
| static int sja1105_tas_set_base_time(struct sja1105_private *priv, |
| u64 base_time) |
| { |
| const struct sja1105_regs *regs = priv->info->regs; |
| u64 ptpschtm = ns_to_sja1105_ticks(base_time); |
| |
| return sja1105_xfer_u64(priv, SPI_WRITE, regs->ptpschtm, |
| &ptpschtm, NULL); |
| } |
| |
| static int sja1105_tas_start(struct sja1105_private *priv) |
| { |
| struct sja1105_tas_data *tas_data = &priv->tas_data; |
| struct sja1105_ptp_cmd *cmd = &priv->ptp_data.cmd; |
| struct dsa_switch *ds = priv->ds; |
| int rc; |
| |
| dev_dbg(ds->dev, "Starting the TAS\n"); |
| |
| if (tas_data->state == SJA1105_TAS_STATE_ENABLED_NOT_RUNNING || |
| tas_data->state == SJA1105_TAS_STATE_RUNNING) { |
| dev_err(ds->dev, "TAS already started\n"); |
| return -EINVAL; |
| } |
| |
| cmd->ptpstrtsch = 1; |
| cmd->ptpstopsch = 0; |
| |
| rc = sja1105_ptp_commit(ds, cmd, SPI_WRITE); |
| if (rc < 0) |
| return rc; |
| |
| tas_data->state = SJA1105_TAS_STATE_ENABLED_NOT_RUNNING; |
| |
| return 0; |
| } |
| |
| static int sja1105_tas_stop(struct sja1105_private *priv) |
| { |
| struct sja1105_tas_data *tas_data = &priv->tas_data; |
| struct sja1105_ptp_cmd *cmd = &priv->ptp_data.cmd; |
| struct dsa_switch *ds = priv->ds; |
| int rc; |
| |
| dev_dbg(ds->dev, "Stopping the TAS\n"); |
| |
| if (tas_data->state == SJA1105_TAS_STATE_DISABLED) { |
| dev_err(ds->dev, "TAS already disabled\n"); |
| return -EINVAL; |
| } |
| |
| cmd->ptpstopsch = 1; |
| cmd->ptpstrtsch = 0; |
| |
| rc = sja1105_ptp_commit(ds, cmd, SPI_WRITE); |
| if (rc < 0) |
| return rc; |
| |
| tas_data->state = SJA1105_TAS_STATE_DISABLED; |
| |
| return 0; |
| } |
| |
| /* The schedule engine and the PTP clock are driven by the same oscillator, and |
| * they run in parallel. But whilst the PTP clock can keep an absolute |
| * time-of-day, the schedule engine is only running in 'ticks' (25 ticks make |
| * up a delta, which is 200ns), and wrapping around at the end of each cycle. |
| * The schedule engine is started when the PTP clock reaches the PTPSCHTM time |
| * (in PTP domain). |
| * Because the PTP clock can be rate-corrected (accelerated or slowed down) by |
| * a software servo, and the schedule engine clock runs in parallel to the PTP |
| * clock, there is logic internal to the switch that periodically keeps the |
| * schedule engine from drifting away. The frequency with which this internal |
| * syntonization happens is the PTP clock correction period (PTPCLKCORP). It is |
| * a value also in the PTP clock domain, and is also rate-corrected. |
| * To be precise, during a correction period, there is logic to determine by |
| * how many scheduler clock ticks has the PTP clock drifted. At the end of each |
| * correction period/beginning of new one, the length of a delta is shrunk or |
| * expanded with an integer number of ticks, compared with the typical 25. |
| * So a delta lasts for 200ns (or 25 ticks) only on average. |
| * Sometimes it is longer, sometimes it is shorter. The internal syntonization |
| * logic can adjust for at most 5 ticks each 20 ticks. |
| * |
| * The first implication is that you should choose your schedule correction |
| * period to be an integer multiple of the schedule length. Preferably one. |
| * In case there are schedules of multiple ports active, then the correction |
| * period needs to be a multiple of them all. Given the restriction that the |
| * cycle times have to be multiples of one another anyway, this means the |
| * correction period can simply be the largest cycle time, hence the current |
| * choice. This way, the updates are always synchronous to the transmission |
| * cycle, and therefore predictable. |
| * |
| * The second implication is that at the beginning of a correction period, the |
| * first few deltas will be modulated in time, until the schedule engine is |
| * properly phase-aligned with the PTP clock. For this reason, you should place |
| * your best-effort traffic at the beginning of a cycle, and your |
| * time-triggered traffic afterwards. |
| * |
| * The third implication is that once the schedule engine is started, it can |
| * only adjust for so much drift within a correction period. In the servo you |
| * can only change the PTPCLKRATE, but not step the clock (PTPCLKADD). If you |
| * want to do the latter, you need to stop and restart the schedule engine, |
| * which is what the state machine handles. |
| */ |
| static void sja1105_tas_state_machine(struct work_struct *work) |
| { |
| struct sja1105_tas_data *tas_data = work_to_sja1105_tas(work); |
| struct sja1105_private *priv = tas_to_sja1105(tas_data); |
| struct sja1105_ptp_data *ptp_data = &priv->ptp_data; |
| struct timespec64 base_time_ts, now_ts; |
| struct dsa_switch *ds = priv->ds; |
| struct timespec64 diff; |
| s64 base_time, now; |
| int rc = 0; |
| |
| mutex_lock(&ptp_data->lock); |
| |
| switch (tas_data->state) { |
| case SJA1105_TAS_STATE_DISABLED: |
| /* Can't do anything at all if clock is still being stepped */ |
| if (tas_data->last_op != SJA1105_PTP_ADJUSTFREQ) |
| break; |
| |
| rc = sja1105_tas_adjust_drift(priv, tas_data->max_cycle_time); |
| if (rc < 0) |
| break; |
| |
| rc = __sja1105_ptp_gettimex(ds, &now, NULL); |
| if (rc < 0) |
| break; |
| |
| /* Plan to start the earliest schedule first. The others |
| * will be started in hardware, by way of their respective |
| * entry points delta. |
| * Try our best to avoid fringe cases (race condition between |
| * ptpschtm and ptpstrtsch) by pushing the oper_base_time at |
| * least one second in the future from now. This is not ideal, |
| * but this only needs to buy us time until the |
| * sja1105_tas_start command below gets executed. |
| */ |
| base_time = future_base_time(tas_data->earliest_base_time, |
| tas_data->max_cycle_time, |
| now + 1ull * NSEC_PER_SEC); |
| base_time -= sja1105_delta_to_ns(1); |
| |
| rc = sja1105_tas_set_base_time(priv, base_time); |
| if (rc < 0) |
| break; |
| |
| tas_data->oper_base_time = base_time; |
| |
| rc = sja1105_tas_start(priv); |
| if (rc < 0) |
| break; |
| |
| base_time_ts = ns_to_timespec64(base_time); |
| now_ts = ns_to_timespec64(now); |
| |
| dev_dbg(ds->dev, "OPER base time %lld.%09ld (now %lld.%09ld)\n", |
| base_time_ts.tv_sec, base_time_ts.tv_nsec, |
| now_ts.tv_sec, now_ts.tv_nsec); |
| |
| break; |
| |
| case SJA1105_TAS_STATE_ENABLED_NOT_RUNNING: |
| if (tas_data->last_op != SJA1105_PTP_ADJUSTFREQ) { |
| /* Clock was stepped.. bad news for TAS */ |
| sja1105_tas_stop(priv); |
| break; |
| } |
| |
| /* Check if TAS has actually started, by comparing the |
| * scheduled start time with the SJA1105 PTP clock |
| */ |
| rc = __sja1105_ptp_gettimex(ds, &now, NULL); |
| if (rc < 0) |
| break; |
| |
| if (now < tas_data->oper_base_time) { |
| /* TAS has not started yet */ |
| diff = ns_to_timespec64(tas_data->oper_base_time - now); |
| dev_dbg(ds->dev, "time to start: [%lld.%09ld]", |
| diff.tv_sec, diff.tv_nsec); |
| break; |
| } |
| |
| /* Time elapsed, what happened? */ |
| rc = sja1105_tas_check_running(priv); |
| if (rc < 0) |
| break; |
| |
| if (tas_data->state != SJA1105_TAS_STATE_RUNNING) |
| /* TAS has started */ |
| dev_err(ds->dev, |
| "TAS not started despite time elapsed\n"); |
| |
| break; |
| |
| case SJA1105_TAS_STATE_RUNNING: |
| /* Clock was stepped.. bad news for TAS */ |
| if (tas_data->last_op != SJA1105_PTP_ADJUSTFREQ) { |
| sja1105_tas_stop(priv); |
| break; |
| } |
| |
| rc = sja1105_tas_check_running(priv); |
| if (rc < 0) |
| break; |
| |
| if (tas_data->state != SJA1105_TAS_STATE_RUNNING) |
| dev_err(ds->dev, "TAS surprisingly stopped\n"); |
| |
| break; |
| |
| default: |
| if (net_ratelimit()) |
| dev_err(ds->dev, "TAS in an invalid state (incorrect use of API)!\n"); |
| } |
| |
| if (rc && net_ratelimit()) |
| dev_err(ds->dev, "An operation returned %d\n", rc); |
| |
| mutex_unlock(&ptp_data->lock); |
| } |
| |
| void sja1105_tas_clockstep(struct dsa_switch *ds) |
| { |
| struct sja1105_private *priv = ds->priv; |
| struct sja1105_tas_data *tas_data = &priv->tas_data; |
| |
| if (!tas_data->enabled) |
| return; |
| |
| tas_data->last_op = SJA1105_PTP_CLOCKSTEP; |
| schedule_work(&tas_data->tas_work); |
| } |
| |
| void sja1105_tas_adjfreq(struct dsa_switch *ds) |
| { |
| struct sja1105_private *priv = ds->priv; |
| struct sja1105_tas_data *tas_data = &priv->tas_data; |
| |
| if (!tas_data->enabled) |
| return; |
| |
| /* No reason to schedule the workqueue, nothing changed */ |
| if (tas_data->state == SJA1105_TAS_STATE_RUNNING) |
| return; |
| |
| tas_data->last_op = SJA1105_PTP_ADJUSTFREQ; |
| schedule_work(&tas_data->tas_work); |
| } |
| |
| void sja1105_tas_setup(struct dsa_switch *ds) |
| { |
| struct sja1105_private *priv = ds->priv; |
| struct sja1105_tas_data *tas_data = &priv->tas_data; |
| |
| INIT_WORK(&tas_data->tas_work, sja1105_tas_state_machine); |
| tas_data->state = SJA1105_TAS_STATE_DISABLED; |
| tas_data->last_op = SJA1105_PTP_NONE; |
| |
| INIT_LIST_HEAD(&tas_data->gating_cfg.entries); |
| } |
| |
| void sja1105_tas_teardown(struct dsa_switch *ds) |
| { |
| struct sja1105_private *priv = ds->priv; |
| struct tc_taprio_qopt_offload *offload; |
| int port; |
| |
| cancel_work_sync(&priv->tas_data.tas_work); |
| |
| for (port = 0; port < SJA1105_NUM_PORTS; port++) { |
| offload = priv->tas_data.offload[port]; |
| if (!offload) |
| continue; |
| |
| taprio_offload_free(offload); |
| } |
| } |