| // SPDX-License-Identifier: GPL-2.0-only |
| /* |
| * Honeywell TruStability HSC Series pressure/temperature sensor |
| * |
| * Copyright (c) 2023 Petre Rodan <petre.rodan@subdimension.ro> |
| * |
| * Datasheet: https://prod-edam.honeywell.com/content/dam/honeywell-edam/sps/siot/en-us/products/sensors/pressure-sensors/common/documents/sps-siot-spi-comms-digital-ouptu-pressure-sensors-tn-008202-3-en-ciid-45843.pdf |
| * Datasheet: https://prod-edam.honeywell.com/content/dam/honeywell-edam/sps/siot/en-us/products/sensors/pressure-sensors/common/documents/sps-siot-sleep-mode-technical-note-008286-1-en-ciid-155793.pdf |
| */ |
| |
| #include <linux/delay.h> |
| #include <linux/device.h> |
| #include <linux/mod_devicetable.h> |
| #include <linux/module.h> |
| #include <linux/spi/spi.h> |
| #include <linux/stddef.h> |
| #include <linux/types.h> |
| |
| #include <linux/iio/iio.h> |
| |
| #include "hsc030pa.h" |
| |
| static int hsc_spi_recv(struct hsc_data *data) |
| { |
| struct spi_device *spi = to_spi_device(data->dev); |
| |
| msleep_interruptible(HSC_RESP_TIME_MS); |
| return spi_read(spi, data->buffer, HSC_REG_MEASUREMENT_RD_SIZE); |
| } |
| |
| static int hsc_spi_probe(struct spi_device *spi) |
| { |
| return hsc_common_probe(&spi->dev, hsc_spi_recv); |
| } |
| |
| static const struct of_device_id hsc_spi_match[] = { |
| { .compatible = "honeywell,hsc030pa" }, |
| {} |
| }; |
| MODULE_DEVICE_TABLE(of, hsc_spi_match); |
| |
| static const struct spi_device_id hsc_spi_id[] = { |
| { "hsc030pa" }, |
| {} |
| }; |
| MODULE_DEVICE_TABLE(spi, hsc_spi_id); |
| |
| static struct spi_driver hsc_spi_driver = { |
| .driver = { |
| .name = "hsc030pa", |
| .of_match_table = hsc_spi_match, |
| }, |
| .probe = hsc_spi_probe, |
| .id_table = hsc_spi_id, |
| }; |
| module_spi_driver(hsc_spi_driver); |
| |
| MODULE_AUTHOR("Petre Rodan <petre.rodan@subdimension.ro>"); |
| MODULE_DESCRIPTION("Honeywell HSC and SSC pressure sensor spi driver"); |
| MODULE_LICENSE("GPL"); |
| MODULE_IMPORT_NS(IIO_HONEYWELL_HSC030PA); |