| .. SPDX-License-Identifier: GPL-2.0 | |
| ================================================ | |
| PLIP: The Parallel Line Internet Protocol Device | |
| ================================================ | |
| Donald Becker (becker@super.org) | |
| I.D.A. Supercomputing Research Center, Bowie MD 20715 | |
| At some point T. Thorn will probably contribute text, | |
| Tommy Thorn (tthorn@daimi.aau.dk) | |
| PLIP Introduction | |
| ----------------- | |
| This document describes the parallel port packet pusher for Net/LGX. | |
| This device interface allows a point-to-point connection between two | |
| parallel ports to appear as a IP network interface. | |
| What is PLIP? | |
| ============= | |
| PLIP is Parallel Line IP, that is, the transportation of IP packages | |
| over a parallel port. In the case of a PC, the obvious choice is the | |
| printer port. PLIP is a non-standard, but [can use] uses the standard | |
| LapLink null-printer cable [can also work in turbo mode, with a PLIP | |
| cable]. [The protocol used to pack IP packages, is a simple one | |
| initiated by Crynwr.] | |
| Advantages of PLIP | |
| ================== | |
| It's cheap, it's available everywhere, and it's easy. | |
| The PLIP cable is all that's needed to connect two Linux boxes, and it | |
| can be built for very few bucks. | |
| Connecting two Linux boxes takes only a second's decision and a few | |
| minutes' work, no need to search for a [supported] netcard. This might | |
| even be especially important in the case of notebooks, where netcards | |
| are not easily available. | |
| Not requiring a netcard also means that apart from connecting the | |
| cables, everything else is software configuration [which in principle | |
| could be made very easy.] | |
| Disadvantages of PLIP | |
| ===================== | |
| Doesn't work over a modem, like SLIP and PPP. Limited range, 15 m. | |
| Can only be used to connect three (?) Linux boxes. Doesn't connect to | |
| an existing Ethernet. Isn't standard (not even de facto standard, like | |
| SLIP). | |
| Performance | |
| =========== | |
| PLIP easily outperforms Ethernet cards....(ups, I was dreaming, but | |
| it *is* getting late. EOB) | |
| PLIP driver details | |
| ------------------- | |
| The Linux PLIP driver is an implementation of the original Crynwr protocol, | |
| that uses the parallel port subsystem of the kernel in order to properly | |
| share parallel ports between PLIP and other services. | |
| IRQs and trigger timeouts | |
| ========================= | |
| When a parallel port used for a PLIP driver has an IRQ configured to it, the | |
| PLIP driver is signaled whenever data is sent to it via the cable, such that | |
| when no data is available, the driver isn't being used. | |
| However, on some machines it is hard, if not impossible, to configure an IRQ | |
| to a certain parallel port, mainly because it is used by some other device. | |
| On these machines, the PLIP driver can be used in IRQ-less mode, where | |
| the PLIP driver would constantly poll the parallel port for data waiting, | |
| and if such data is available, process it. This mode is less efficient than | |
| the IRQ mode, because the driver has to check the parallel port many times | |
| per second, even when no data at all is sent. Some rough measurements | |
| indicate that there isn't a noticeable performance drop when using IRQ-less | |
| mode as compared to IRQ mode as far as the data transfer speed is involved. | |
| There is a performance drop on the machine hosting the driver. | |
| When the PLIP driver is used in IRQ mode, the timeout used for triggering a | |
| data transfer (the maximal time the PLIP driver would allow the other side | |
| before announcing a timeout, when trying to handshake a transfer of some | |
| data) is, by default, 500usec. As IRQ delivery is more or less immediate, | |
| this timeout is quite sufficient. | |
| When in IRQ-less mode, the PLIP driver polls the parallel port HZ times | |
| per second (where HZ is typically 100 on most platforms, and 1024 on an | |
| Alpha, as of this writing). Between two such polls, there are 10^6/HZ usecs. | |
| On an i386, for example, 10^6/100 = 10000usec. It is easy to see that it is | |
| quite possible for the trigger timeout to expire between two such polls, as | |
| the timeout is only 500usec long. As a result, it is required to change the | |
| trigger timeout on the *other* side of a PLIP connection, to about | |
| 10^6/HZ usecs. If both sides of a PLIP connection are used in IRQ-less mode, | |
| this timeout is required on both sides. | |
| It appears that in practice, the trigger timeout can be shorter than in the | |
| above calculation. It isn't an important issue, unless the wire is faulty, | |
| in which case a long timeout would stall the machine when, for whatever | |
| reason, bits are dropped. | |
| A utility that can perform this change in Linux is plipconfig, which is part | |
| of the net-tools package (its location can be found in the | |
| Documentation/Changes file). An example command would be | |
| 'plipconfig plipX trigger 10000', where plipX is the appropriate | |
| PLIP device. | |
| PLIP hardware interconnection | |
| ----------------------------- | |
| PLIP uses several different data transfer methods. The first (and the | |
| only one implemented in the early version of the code) uses a standard | |
| printer "null" cable to transfer data four bits at a time using | |
| data bit outputs connected to status bit inputs. | |
| The second data transfer method relies on both machines having | |
| bi-directional parallel ports, rather than output-only ``printer`` | |
| ports. This allows byte-wide transfers and avoids reconstructing | |
| nibbles into bytes, leading to much faster transfers. | |
| Parallel Transfer Mode 0 Cable | |
| ============================== | |
| The cable for the first transfer mode is a standard | |
| printer "null" cable which transfers data four bits at a time using | |
| data bit outputs of the first port (machine T) connected to the | |
| status bit inputs of the second port (machine R). There are five | |
| status inputs, and they are used as four data inputs and a clock (data | |
| strobe) input, arranged so that the data input bits appear as contiguous | |
| bits with standard status register implementation. | |
| A cable that implements this protocol is available commercially as a | |
| "Null Printer" or "Turbo Laplink" cable. It can be constructed with | |
| two DB-25 male connectors symmetrically connected as follows:: | |
| STROBE output 1* | |
| D0->ERROR 2 - 15 15 - 2 | |
| D1->SLCT 3 - 13 13 - 3 | |
| D2->PAPOUT 4 - 12 12 - 4 | |
| D3->ACK 5 - 10 10 - 5 | |
| D4->BUSY 6 - 11 11 - 6 | |
| D5,D6,D7 are 7*, 8*, 9* | |
| AUTOFD output 14* | |
| INIT output 16* | |
| SLCTIN 17 - 17 | |
| extra grounds are 18*,19*,20*,21*,22*,23*,24* | |
| GROUND 25 - 25 | |
| * Do not connect these pins on either end | |
| If the cable you are using has a metallic shield it should be | |
| connected to the metallic DB-25 shell at one end only. | |
| Parallel Transfer Mode 1 | |
| ======================== | |
| The second data transfer method relies on both machines having | |
| bi-directional parallel ports, rather than output-only ``printer`` | |
| ports. This allows byte-wide transfers, and avoids reconstructing | |
| nibbles into bytes. This cable should not be used on unidirectional | |
| ``printer`` (as opposed to ``parallel``) ports or when the machine | |
| isn't configured for PLIP, as it will result in output driver | |
| conflicts and the (unlikely) possibility of damage. | |
| The cable for this transfer mode should be constructed as follows:: | |
| STROBE->BUSY 1 - 11 | |
| D0->D0 2 - 2 | |
| D1->D1 3 - 3 | |
| D2->D2 4 - 4 | |
| D3->D3 5 - 5 | |
| D4->D4 6 - 6 | |
| D5->D5 7 - 7 | |
| D6->D6 8 - 8 | |
| D7->D7 9 - 9 | |
| INIT -> ACK 16 - 10 | |
| AUTOFD->PAPOUT 14 - 12 | |
| SLCT->SLCTIN 13 - 17 | |
| GND->ERROR 18 - 15 | |
| extra grounds are 19*,20*,21*,22*,23*,24* | |
| GROUND 25 - 25 | |
| * Do not connect these pins on either end | |
| Once again, if the cable you are using has a metallic shield it should | |
| be connected to the metallic DB-25 shell at one end only. | |
| PLIP Mode 0 transfer protocol | |
| ============================= | |
| The PLIP driver is compatible with the "Crynwr" parallel port transfer | |
| standard in Mode 0. That standard specifies the following protocol:: | |
| send header nibble '0x8' | |
| count-low octet | |
| count-high octet | |
| ... data octets | |
| checksum octet | |
| Each octet is sent as:: | |
| <wait for rx. '0x1?'> <send 0x10+(octet&0x0F)> | |
| <wait for rx. '0x0?'> <send 0x00+((octet>>4)&0x0F)> | |
| To start a transfer the transmitting machine outputs a nibble 0x08. | |
| That raises the ACK line, triggering an interrupt in the receiving | |
| machine. The receiving machine disables interrupts and raises its own ACK | |
| line. | |
| Restated:: | |
| (OUT is bit 0-4, OUT.j is bit j from OUT. IN likewise) | |
| Send_Byte: | |
| OUT := low nibble, OUT.4 := 1 | |
| WAIT FOR IN.4 = 1 | |
| OUT := high nibble, OUT.4 := 0 | |
| WAIT FOR IN.4 = 0 |