| # SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause) |
| %YAML 1.2 |
| --- |
| $id: http://devicetree.org/schemas/rtc/ti,palmas-rtc.yaml# |
| $schema: http://devicetree.org/meta-schemas/core.yaml# |
| |
| title: Texas Instruments Palmas RTC |
| |
| maintainers: |
| - Eduard Bostina <egbostina@gmail.com> |
| |
| allOf: |
| - $ref: /schemas/rtc/rtc.yaml# |
| |
| properties: |
| compatible: |
| const: ti,palmas-rtc |
| |
| interrupts: |
| maxItems: 1 |
| |
| wakeup-source: true |
| |
| ti,backup-battery-chargeable: |
| type: boolean |
| description: |
| The backup battery can be chargeable or non-chargeable. This flag |
| indicates whether the battery is chargeable. If present, the driver |
| can enable charging. |
| |
| ti,backup-battery-charge-high-current: |
| type: boolean |
| description: |
| Enable high current charging in the backup battery. |
| Device supports the < 100uA and > 100uA charging. The high current will |
| be > 100uA. Absence of this property will charge battery to lower |
| current i.e. < 100uA. |
| |
| required: |
| - compatible |
| - interrupts |
| |
| unevaluatedProperties: false |
| |
| examples: |
| - | |
| pmic { |
| #address-cells = <1>; |
| #size-cells = <0>; |
| |
| rtc { |
| compatible = "ti,palmas-rtc"; |
| interrupts = <8 0>; |
| ti,backup-battery-chargeable; |
| ti,backup-battery-charge-high-current; |
| }; |
| }; |