| /* SPDX-License-Identifier: GPL-2.0 */ |
| #ifndef _ARCH_X86_CPUID_PARSER_H |
| #define _ARCH_X86_CPUID_PARSER_H |
| |
| #include <asm/cpuid/types.h> |
| |
| /* |
| * Since accessing the CPUID leaves at 'struct cpuid_leaves' require compile time |
| * tokenization, split the CPUID parser into two stages: compile time macros for |
| * tokenizing the leaf/subleaf output offsets within the table, and generic runtime |
| * code to write to the relevant CPUID leaves using such offsets. |
| * |
| * The output of the compile time macros is cached by a compile time "parse entry" |
| * table (see 'struct cpuid_parse_entry'). The runtime parser code will utilize |
| * such offsets by passing them to the cpuid_table_*_p() functions. |
| */ |
| |
| /* |
| * Compile time CPUID table offset calculations: |
| * |
| * @_leaf: CPUID leaf, in 0xN format |
| * @_subleaf: CPUID subleaf, in decimal format |
| */ |
| |
| #define __cpuid_leaves_regs_offset(_leaf, _subleaf) \ |
| offsetof(struct cpuid_leaves, leaf_ ## _leaf ## _ ## _subleaf) |
| |
| #define __cpuid_leaves_info_offset(_leaf, _subleaf) \ |
| offsetof(struct cpuid_leaves, leaf_ ## _leaf ## _ ## _subleaf ## _ ## info) |
| |
| #define __cpuid_leaves_regs_maxcnt(_leaf, _subleaf) \ |
| ARRAY_SIZE(((struct cpuid_leaves *)NULL)->leaf_ ## _leaf ## _ ## _subleaf) |
| |
| /* |
| * Translation of compile time offsets to generic runtime pointers: |
| */ |
| |
| static inline struct cpuid_regs *cpuid_table_regs_p(const struct cpuid_table *t, |
| unsigned long regs_offset) |
| { |
| return (struct cpuid_regs *)((unsigned long)(&t->leaves) + regs_offset); |
| } |
| |
| static inline struct leaf_parse_info *cpuid_table_info_p(const struct cpuid_table *t, |
| unsigned long info_offset) |
| { |
| return (struct leaf_parse_info *)((unsigned long)(&t->leaves) + info_offset); |
| } |
| |
| /** |
| * struct cpuid_output - Output of a CPUID operation |
| * @regs: Pointer to an array of CPUID results, where each array element covers the |
| * full EAX->EDX output range. |
| * @info: Pointer to query info; for saving the number of filled elements at @regs. |
| * |
| * A CPUID parser read function like cpuid_read_generic() or cpuid_read_0xN() uses this |
| * structure to save the CPUID query outputs. Actual storage for @regs and @info is |
| * provided by the read function caller, and is typically within the CPU's CPUID table. |
| * |
| * See struct cpuid_parse_entry.read(). |
| */ |
| struct cpuid_output { |
| struct cpuid_regs *regs; |
| struct leaf_parse_info *info; |
| }; |
| |
| /** |
| * struct cpuid_parse_entry - CPUID parse table entry |
| * @leaf: Leaf number to be parsed |
| * @subleaf: Subleaf number to be parsed |
| * @regs_offs: Offset within 'struct cpuid_leaves' for saving the CPUID query output; to be |
| * passed to cpuid_table_regs_p(). |
| * @info_offs: Offset within 'struct cpuid_leaves' for saving the CPUID query parse info; to be |
| * passed to cpuid_table_info_p(). |
| * @maxcnt: Maximum number of output storage entries available for the CPUID query. |
| * @read: Read function for this entry. It must save the parsed CPUID output to the passed |
| * 'struct cpuid_output'->regs array of size >= @maxcnt. It must set |
| * 'struct cpuid_output'->info.nr_entries to the number of CPUID output entries |
| * parsed and filled. A generic implementation is provided at cpuid_read_generic(). |
| */ |
| struct cpuid_parse_entry { |
| unsigned int leaf; |
| unsigned int subleaf; |
| unsigned int regs_offs; |
| unsigned int info_offs; |
| unsigned int maxcnt; |
| void (*read)(const struct cpuid_parse_entry *e, const struct cpuid_output *o); |
| }; |
| |
| #define __CPUID_PARSE_ENTRY(_leaf, _subleaf, _suffix, _reader_fn) \ |
| { \ |
| .leaf = _leaf, \ |
| .subleaf = _subleaf, \ |
| .regs_offs = __cpuid_leaves_regs_offset(_leaf, _suffix), \ |
| .info_offs = __cpuid_leaves_info_offset(_leaf, _suffix), \ |
| .maxcnt = __cpuid_leaves_regs_maxcnt(_leaf, _suffix), \ |
| .read = cpuid_read_ ## _reader_fn, \ |
| } |
| |
| /* |
| * CPUID_PARSE_ENTRY_N() is for parsing CPUID leaves with a subleaf range. |
| * Check <asm/cpuid/types.h> __CPUID_LEAF() vs. CPUID_LEAF_N(). |
| */ |
| |
| #define CPUID_PARSE_ENTRY(_leaf, _subleaf, _reader_fn) \ |
| __CPUID_PARSE_ENTRY(_leaf, _subleaf, _subleaf, _reader_fn) |
| |
| #define CPUID_PARSE_ENTRY_N(_leaf, _reader_fn) \ |
| __CPUID_PARSE_ENTRY(_leaf, __cpuid_leaf_first_subleaf(_leaf), n, _reader_fn) |
| |
| /* |
| * CPUID parser table: |
| */ |
| |
| #define CPUID_PARSE_ENTRIES \ |
| /* Leaf Subleaf Reader function */ \ |
| CPUID_PARSE_ENTRY ( 0x0, 0, generic ), \ |
| CPUID_PARSE_ENTRY ( 0x1, 0, generic ), \ |
| |
| #endif /* _ARCH_X86_CPUID_PARSER_H */ |